3

© Copyright 2016 Zoeller

®

 Co. All rights reserved.

  1.  Remove all debris from pit before installation.

 

  2.  Use a deep cycle battery only. Refer to battery descrip-

tions on page 6.

  3.  Be sure the pump is on a firm, level surface.

 

 4.  Install a serviceable check valve in the discharge 

line.

 5. Test the unit immediately after installation. Refer to 

STEP 6.

 1.  DO read all installation material with the pump and 

charger.

  2.  DO inspect unit for any visible damage caused by ship-

ping. Contact dealer if unit appears to be damaged.

  3.  DO clean all debris from the pit.

  4.   DO always disconnect pump from power source before 

handling. DO always connect to a separately protected 

and properly grounded ground fault protected circuit. 

DO NOT ever cut, splice or damage power cord. DO 

Ten Helpful Hints For Easy Installation

Do’s  And  Don’t’s  For  Installing  A  Unit

NOT carry or lift pump by its power cord. DO NOT use 

an extension cord with the 

Aquanot

®

. DO NOT lengthen 

battery/pump leads.

  5.  DO install union check valve (see step 3) in the dis-

charge line. DO NOT use

 

a discharge pipe smaller 

than the recommended pump discharge sizes.

  6.  DO test pump immediately after installation to be sure 

that the system is working properly.

  7.  DO review all applicable local and national codes and 

verify that the installation conforms to each of them. 

Performance Characteristics

  6.  The battery  & charger should be placed on a shelf.

  7.  Check float On/Off levels per STEP 2 of instructions.

  8.  Apply grease to the Positive and Negative terminals 

of the battery to prevent corrosion.

  9.  Check the battery water level once a month and add 

distilled water as necessary.

 10. Obtain model number, date code and installation in-

structions before calling factory.

011922

 

Note:

 

Aquanot

®

 

II

 (Model 585) data was developed with the charger supplying DC power to the pump.

TOTAL DYNAMIC HEAD/FLOW

PER MINUTE

EFFLUENT AND DEWATERING

MODEL

Feet

Shut-off Head:

585

Meters

Gal.

Liters

5

1.5

49

186

10

3.0

36

136

15

4.6

25

95

20 ft.(6.1m)

10

GALLONS
LITERS

0

20

0

2

5

5

TO

TAL D

YNAMIC HEAD

4

15

6

20

METERS

FEET

8

25

30

FLOW PER MINUTE

40

60

80

100

20

10

15

25

120

140

160

180

40

35

45

50

200

55

PUMP PERFORMANCE CURVE

MODEL 585

585

Содержание AquaNot 585

Страница 1: ...th a primary and a DC backup pump SEE BELOW FOR LIST OF WARNINGS 1 Testing for Ground As a safety measure each electrical outlet should be checked for ground using an Underwriters Laboratory listed circuit analyzer which will indicate if the power neutral and ground wires are correctly connected to your outlet If they are not call a qualified licensed electrician 2 For your protection always disco...

Страница 2: ...nty MANUFACTURER EXPRESSLY DISCLAIMS LIABILITY FOR SPECIAL CONSEQUENTIAL OR INCIDENTAL DAMAGES OR BREACH OF EXPRESSED OR IMPLIED WARRANTY AND ANY IMPLIED WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE AND OF MERCHANTABILITY SHALL BE LIMITED TO THE DURATION OF THE EXPRESSED WARRANTY Some states do not allow limitations on the duration of an implied warranty so the above limitation may not apply to yo...

Страница 3: ...k valve see step 3 in the dis charge line DO NOT use a discharge pipe smaller than the recommended pump discharge sizes 6 DO test pump immediately after installation to be sure that the system is working properly 7 DO review all applicable local and national codes and verify that the installation conforms to each of them Performance Characteristics 6 The battery charger should be placed on a shelf...

Страница 4: ...rick or similar material has been used to raise the pump in the pit it will be necessary to account for the thickness of the brick Figure 2 2 Figure 2 1 SK1776 SK1777 STEP 1 Placement of the Pump in the Pit Note If your pit has a cover then it will have to be modified to accept the Aquanot 1 1 Inspect the pit for debris and clean as necessary 1 2 Place the pump in the pit making certain that it is...

Страница 5: ...the Aquanot starts 6 3 Verify that the pump starts and stops at the desired on off points 6 4 Verify that there are no leaks in the discharge line 6 5 If adjustment is necessary raise or lower the appropriate stop s according to STEP 2 IMPORTANT Spacing between upper and lower stops determine amount of water removed from pit 6 6 If the pump is not operating properly after following the above steps...

Страница 6: ...he condition of the battery Operation of the Aquanot Charger All Aquanot pump systems are equipped with an alarm which sounds when the pump is activated The alarm will automatically silence when the pumping cycle is completed Activation of the audible alarm indicates that the primary pump has failed or line power to the primary pump is not present When ever the alarm is activated the primary pump ...

Страница 7: ...p Motor 1 013873 013873 013873 013873 013873 013873 013873 013873 013873 013873 013873 013873 9 Column 1 011942 011942 011942 011942 011942 011942 011942 011942 011942 011942 011942 011942 10 Adapter Drive 1 011940 011940 011940 011940 011940 011940 011940 011940 011940 011940 011940 011940 11 Shaft 1 011944 011944 011944 011944 011944 011944 011944 011944 011944 011944 011944 011944 12 Head w Bra...

Страница 8: ...han 5V Battery has depleted below 5V due to prolonged operation without AC power Call for service or replace battery F RED LIGHT FLASHING The charger fan may be defective Have a qualified electrician inspect the charger G GREEN YELLOW LIGHTS FLASH INTERMITTENTLY Positive Negative battery leads are reversed Make certain that the positive red negative black leads go to the proper battery terminals B...

Отзывы: