background image

2

© Copyright 2016 Zoeller

®

 Co. All rights reserved.

Manufacturer warrants, to the purchaser and subsequent owner 

during the warranty period, every new product to be free from defects 

in material and workmanship under normal use and service, when 

properly used and maintained, for a period of 3 years from date of 

purchase by the end user.  Parts that fail within the warranty period, 

that inspections determine to be defective in material or workmanship, 

will be repaired, replaced or remanufactured at Manufacturer’s option, 

provided however, that by so doing we will not be obligated to replace 

an entire assembly, the entire mechanism or the complete unit.  No 

allowance will be made for shipping charges, damages, labor or other 

charges that may occur due to product failure, repair or replacement.

This warranty does not apply to and there shall be no warranty for 

any material or product that has been disassembled without prior 

approval of Manufacturer, subjected to misuse, misapplication, 

neglect, alteration, accident or act of God; that has not been installed, 

operated or maintained in accordance with Manufacturer's installation 

instructions; that has been exposed to outside substances including 

but not limited to the following:  sand, gravel, cement, mud, tar, 

hydrocarbons, hydrocarbon derivatives (oil, gasoline, solvents, etc.), 

or other abrasive or corrosive substances, wash towels or feminine 

sanitary products, etc. in all pumping applications.  The warranty set 

out in the paragraph above is in lieu of all other warranties expressed 

or implied; and we do not authorize any representative or other person 

to assume for us any other liability in connection with our products.

Contact Manufacturer at, 3649 Cane Run Road, Louisville, Kentucky  

40211, Attention: Customer Service Department to obtain any needed 

repair or replacement of part(s) or additional information pertaining 

to our warranty.

MANUFACTURER EXPRESSLY DISCLAIMS LIABILITY FOR 

SPECIAL, CONSEQUENTIAL OR INCIDENTAL DAMAGES OR 

BREACH OF EXPRESSED OR IMPLIED WARRANTY; AND 

ANY IMPLIED WARRANTY OF FITNESS FOR A PARTICULAR 

PURPOSE AND OF MERCHANTABILITY SHALL BE LIMITED TO 

THE DURATION OF THE EXPRESSED WARRANTY.

Some states do not allow limitations on the duration of an implied 

warranty, so the above limitation may not apply to you. Some states 

do not allow the exclusion or limitation of incidental or consequential 

damages, so the above limitation or exclusion may not apply to you.

This warranty gives you specific legal rights and you may also have 

other rights which vary from state to state.

Limited Warranty

  Whether you have an Aquanot

®

 Battery Backup Sump Pump System, or a competitive brand, all batteries give off gaseous by-products when 

charging. Some of these by-products can produce a rotten egg odor. Also, some of these by-products can cause a CO detector to falsely 

activate. In order to help prevent false activation, Zoeller recommends moving the battery as far apart from the CO detector as possible or, if 

necessary, vent the battery to the exterior. Zoeller provides the previous statements only as guidelines to help prevent false activation of the 

CO detector. In no way are they meant to supersede the instructions that accompany the detector nor do they supersede advice from the CO 

detector manufacturer.

  If the audible alarm associated with your CO detector is activated, we recommend the following actions:

  1)  Take immediate action for personal safety as recommended in the CO detector literature.

  2)  Contact the appropriate agency to determine if the CO is being produced by your furnace, water heater, or any other device which uses 

natural gas.

  3)  If you are certain that no CO is being produced, then a charging battery may be producing gaseous by-products which are causing the 

CO detector to activate. Contact the manufacturer of the CO detector, and ask for recommendations as to what can be done to prevent 

the alarm activation.

Carbon Monoxide Detectors

Содержание AquaNot 585

Страница 1: ...th a primary and a DC backup pump SEE BELOW FOR LIST OF WARNINGS 1 Testing for Ground As a safety measure each electrical outlet should be checked for ground using an Underwriters Laboratory listed circuit analyzer which will indicate if the power neutral and ground wires are correctly connected to your outlet If they are not call a qualified licensed electrician 2 For your protection always disco...

Страница 2: ...nty MANUFACTURER EXPRESSLY DISCLAIMS LIABILITY FOR SPECIAL CONSEQUENTIAL OR INCIDENTAL DAMAGES OR BREACH OF EXPRESSED OR IMPLIED WARRANTY AND ANY IMPLIED WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE AND OF MERCHANTABILITY SHALL BE LIMITED TO THE DURATION OF THE EXPRESSED WARRANTY Some states do not allow limitations on the duration of an implied warranty so the above limitation may not apply to yo...

Страница 3: ...k valve see step 3 in the dis charge line DO NOT use a discharge pipe smaller than the recommended pump discharge sizes 6 DO test pump immediately after installation to be sure that the system is working properly 7 DO review all applicable local and national codes and verify that the installation conforms to each of them Performance Characteristics 6 The battery charger should be placed on a shelf...

Страница 4: ...rick or similar material has been used to raise the pump in the pit it will be necessary to account for the thickness of the brick Figure 2 2 Figure 2 1 SK1776 SK1777 STEP 1 Placement of the Pump in the Pit Note If your pit has a cover then it will have to be modified to accept the Aquanot 1 1 Inspect the pit for debris and clean as necessary 1 2 Place the pump in the pit making certain that it is...

Страница 5: ...the Aquanot starts 6 3 Verify that the pump starts and stops at the desired on off points 6 4 Verify that there are no leaks in the discharge line 6 5 If adjustment is necessary raise or lower the appropriate stop s according to STEP 2 IMPORTANT Spacing between upper and lower stops determine amount of water removed from pit 6 6 If the pump is not operating properly after following the above steps...

Страница 6: ...he condition of the battery Operation of the Aquanot Charger All Aquanot pump systems are equipped with an alarm which sounds when the pump is activated The alarm will automatically silence when the pumping cycle is completed Activation of the audible alarm indicates that the primary pump has failed or line power to the primary pump is not present When ever the alarm is activated the primary pump ...

Страница 7: ...p Motor 1 013873 013873 013873 013873 013873 013873 013873 013873 013873 013873 013873 013873 9 Column 1 011942 011942 011942 011942 011942 011942 011942 011942 011942 011942 011942 011942 10 Adapter Drive 1 011940 011940 011940 011940 011940 011940 011940 011940 011940 011940 011940 011940 11 Shaft 1 011944 011944 011944 011944 011944 011944 011944 011944 011944 011944 011944 011944 12 Head w Bra...

Страница 8: ...han 5V Battery has depleted below 5V due to prolonged operation without AC power Call for service or replace battery F RED LIGHT FLASHING The charger fan may be defective Have a qualified electrician inspect the charger G GREEN YELLOW LIGHTS FLASH INTERMITTENTLY Positive Negative battery leads are reversed Make certain that the positive red negative black leads go to the proper battery terminals B...

Отзывы: