NOTICE TO INSTALLER:  Instructions must remain with installation.

MODEL 585

BATTERY BACKUP PEDESTAL SUMP PUMP

P/N 01

1952

PREINSTALLATION CHECKLIST

ANY CHANGES TO THIS DOCUMENT MAY ALSO AFFECT  FW0264, HF1619 AND GR2249.

ALSO, 

SEND UPDATED PDF FILE TO PURCHASING FOR CLIPLIGHT CO.

 AS OF 4/7/9, FW0264 AND GR2249 

FILES WILL BE KEPT UP TO DATE BUT NOT PRINTED DUE TO LACK OF SALES OF THESE PRODUCTS.

1.  Inspect your pump. Occasionally, products are damaged during shipment. If the unit or any of the parts are damaged, contact your dealer 

before using.

2.  Read all the installation instructions regarding installing and start up. Retain for future reference.

1.  Make sure there is a properly grounded 115V receptacle avail-

able. Do not use primary pump circuit. The location must be within 

6' of the control box and battery. The power supply for your DC 

control system plugs directly into the 115V outlet. DO NOT USE 

AN EXTENSION CORD.

2.  Make sure the 115V electrical supply circuit is equipped 

with fuses or circuit breakers of proper capacity.

3.  DC emergency pumps are designed for handling clear water. Do 

not use in septic tanks to pump effluent or sewage pits to pump 

sewage.

4.  Repair and service of your DC backup system should be performed 

by an authorized service station.

5.  The installation of DC automatic backup pumps requires the use 

of a variable level float switch for operation. It is the responsibility 

of the installing party, to ensure that the tethered float switch will 

not hang up on the pump apparatus or pit peculiarities and is 

secured so the pump will turn “on” and “off”. It is recommended 

that the pit be 18" in diameter or larger to accommodate both a 

primary and a DC backup pump. 

SEE BELOW FOR LIST OF WARNINGS

1.  Testing for Ground. As a safety measure each electrical outlet 

should be checked for ground using an Underwriters Laboratory 

listed circuit analyzer, which will indicate if the power, neutral and 

ground wires are correctly connected to your outlet. If they are 

not, call a qualified licensed electrician.

2.  For your protection always disconnect the power supply from 

its power source before handling the components of your DC 

backup pump or the primary pump.

3.  Installation and checking of electrical circuits and hardware should 

be performed by a qualified, licensed electrician. 

4.  All electrical and safety codes must be followed in addition to 

the National Electrical Code and all applicable local codes. 

5.  

It is the owner’s responsibility to check the battery and 

battery connection at least once a month. Batteries      

contain acid and caution must be taken when handling.

6.  Risk of electric shock - These pumps have not been investigated 

for use in swimming pool areas.

7.  Prop65 Warning for California residents: Cancer and Reproductive 

Harm- www.P65Warnings.ca.gov.

CAUTION

SEE BELOW FOR LIST OF CAUTIONS

REFER TO WARRANTY ON PAGE 2.

Product information presented 

here reflects conditions at time 

of  publication. Consult factory 

regarding discrepancies or 

inconsistencies.

MAIL TO:  P.O. BOX 16347 • Louisville, KY  40256-0347

SHIP TO:  3649 Cane Run Road  • Louisville, KY  40211-1961

TEL: (502) 778-2731 • 1 (800) 928-PUMP • FAX: (502) 774-3624

Visit our web site:

zoellerpumps.com

© Copyright 2016 Zoeller

®

 Co. All rights reserved.

Register your 

Zoeller Pump Company 

Product on our website:

http://reg.zoellerpumps.com/

Содержание AquaNot 585

Страница 1: ...th a primary and a DC backup pump SEE BELOW FOR LIST OF WARNINGS 1 Testing for Ground As a safety measure each electrical outlet should be checked for ground using an Underwriters Laboratory listed circuit analyzer which will indicate if the power neutral and ground wires are correctly connected to your outlet If they are not call a qualified licensed electrician 2 For your protection always disco...

Страница 2: ...nty MANUFACTURER EXPRESSLY DISCLAIMS LIABILITY FOR SPECIAL CONSEQUENTIAL OR INCIDENTAL DAMAGES OR BREACH OF EXPRESSED OR IMPLIED WARRANTY AND ANY IMPLIED WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE AND OF MERCHANTABILITY SHALL BE LIMITED TO THE DURATION OF THE EXPRESSED WARRANTY Some states do not allow limitations on the duration of an implied warranty so the above limitation may not apply to yo...

Страница 3: ...k valve see step 3 in the dis charge line DO NOT use a discharge pipe smaller than the recommended pump discharge sizes 6 DO test pump immediately after installation to be sure that the system is working properly 7 DO review all applicable local and national codes and verify that the installation conforms to each of them Performance Characteristics 6 The battery charger should be placed on a shelf...

Страница 4: ...rick or similar material has been used to raise the pump in the pit it will be necessary to account for the thickness of the brick Figure 2 2 Figure 2 1 SK1776 SK1777 STEP 1 Placement of the Pump in the Pit Note If your pit has a cover then it will have to be modified to accept the Aquanot 1 1 Inspect the pit for debris and clean as necessary 1 2 Place the pump in the pit making certain that it is...

Страница 5: ...the Aquanot starts 6 3 Verify that the pump starts and stops at the desired on off points 6 4 Verify that there are no leaks in the discharge line 6 5 If adjustment is necessary raise or lower the appropriate stop s according to STEP 2 IMPORTANT Spacing between upper and lower stops determine amount of water removed from pit 6 6 If the pump is not operating properly after following the above steps...

Страница 6: ...he condition of the battery Operation of the Aquanot Charger All Aquanot pump systems are equipped with an alarm which sounds when the pump is activated The alarm will automatically silence when the pumping cycle is completed Activation of the audible alarm indicates that the primary pump has failed or line power to the primary pump is not present When ever the alarm is activated the primary pump ...

Страница 7: ...p Motor 1 013873 013873 013873 013873 013873 013873 013873 013873 013873 013873 013873 013873 9 Column 1 011942 011942 011942 011942 011942 011942 011942 011942 011942 011942 011942 011942 10 Adapter Drive 1 011940 011940 011940 011940 011940 011940 011940 011940 011940 011940 011940 011940 11 Shaft 1 011944 011944 011944 011944 011944 011944 011944 011944 011944 011944 011944 011944 12 Head w Bra...

Страница 8: ...han 5V Battery has depleted below 5V due to prolonged operation without AC power Call for service or replace battery F RED LIGHT FLASHING The charger fan may be defective Have a qualified electrician inspect the charger G GREEN YELLOW LIGHTS FLASH INTERMITTENTLY Positive Negative battery leads are reversed Make certain that the positive red negative black leads go to the proper battery terminals B...

Отзывы: