background image

7

© Copyright 2019 Zoeller

®

 Co. All rights reserved.

CARBON MONOXIDE DETECTORS

Whether you have an Aquanot

®

 Backup Pump System or a competitive brand, all use batteries that give off gaseous by-products when charging. Some of these 

by-products can produce a rotten egg odor. Also, some of these by-products can cause a CO detector to falsely activate. In order to help prevent false activation, 

Zoeller Pump Company recommends moving the battery as far away from the CO detector as possible or, if necessary, vent the battery to the exterior. Zoeller 
Pump Company provides the previous statements only as guidelines to help prevent false activation of the CO detector. In no way are they meant to supersede 
the instructions that accompany the detector, nor do they supersede advice from the CO detector manufacturer.

If the audible alarm associated with your CO detector is activated, we recommend the following actions:

1) 

Take immediate action for personal safety as recommended in the CO detector literature.

2) 

Contact the appropriate agency to determine if the CO is being produced by your furnace, water heater, or any other device which uses natural gas.

3) 

If you are certain that no CO is being produced, a charging battery may be producing gaseous by-products which are causing the CO detector to activate. 

Contact the manufacturer and ask for recommendations to prevent the alarm activation.

There are millions of batteries manufactured each year, so it is impossible to guarantee consistent quality.  A defective battery will never become fully 

charged and may damage the charging circuits of the  Control. It is for this reason that Zoeller Pump Company offers its own line of batteries.  We offer 

both a water/acid deep-cycle battery and a maintenance-free AGM battery which can run the pump continuously for over 5 hours.  These times are based 

on continuous pumping at 8' (2.4 m) of static head. Actual times will vary depending on static head, volume of water entering the pit, and the condition of 

the battery.

Follow these recommendations:

•  Use a B.C.I. size 27 deep-cycle battery, 175 minute reserve capacity, or larger

•  Do NOT use a “maintenance-free” battery unless it is an AGM battery

•  Replace your battery every 3 years

•  Do not let corrosion build up on the battery terminals

•  To check specific gravity, follow the instructions on a hydrometer (wet cell batteries only)

•  Use of the included plastic battery box is recommended to keep the battery safe and clean. 

PROTECT YOUR WARRANTY:  

•  Water level in batteries must be checked once a month (wet cell batteries only)

THE AQUANOT

®

 

BATTERY

Содержание AquaNot 508 Spin

Страница 1: ... tanks to pump effluent or in sewage pits to pump sewage 4 Repair and service of your DC backup system should be performed by an authorized service station 5 TheinstallationofDCautomaticbackuppumpsrequirestheuseofavariable level float switch for operation It is the responsibility of the installing party to ensure that the float switch will not hang up on the pump apparatus or pit peculiarities and...

Страница 2: ...e states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from state to state 1 Inspect and test the system for proper operations at least every 3 months a Green system ready indicator light should be on indicating AC p...

Страница 3: ...pump using the clamp provided Make certain the clamp is tight on the pipe to avoid slippage Ensure that the off level of the float is 1 2 5 cm minimum above the outlet of the DC backup pump Position the pumps in the sump and move float up and down ensuring free movement without interference from any obstructions inside the sump or lid The float switch can be moved on the discharge pipe or the rubb...

Страница 4: ...l recharge if green power on light indicates power has been restored and the float switch is in the off position b If immediate usage is required remove and replace dead battery with a full recharged battery c Duetovaryingconditionsthepumpmaycontinuetorunonalowbattery without sufficient power to remove water Pump will not stop running until battery is below minimum voltage d CAUTION Weak batteries...

Страница 5: ...GHER THAN DC BACKUP PUMP FIG 1 DC PUMP INSTALLED IN LINE WITH SUBMERSIBLE PUMP BATTERY BOX AQUANOT SPIN CONTROLLER HIGH WATER REED SENSOR OPTIONAL OUTLET PRIMARY PUMP OUTLET CONTROLLER OPERATIONAL FLOAT SWITCH 30 AMP FUSE HI WATER REED SENSOR OPTIONAL BATTERY BOX DC PUMP 12 VOLT BATTERY SUPPLIED BY USER WHITE LEAD TO POSITIVE BLACK LEAD TO NEGATIVE CLAMP AQUANOT SPIN CONTROLLER EXPLODED VIEW DC PU...

Страница 6: ...SPIN Solid Flashing Off System Ready No Faults Green AC off with no faults Green Battery Charged Green Low Battery Red No AC Power Charging Yellow Bad Battery Red DC pump Pump Ran Yellow Pump Running Yellow Pump Fault Red Float Status High Water Red Sensor Activated Float Fault Red The LEDs will display information about the controller Copyright 2019 Zoeller Co All rights reserved LOCKING PIN MUST...

Страница 7: ...being produced a charging battery may be producing gaseous by products which are causing the CO detector to activate Contact the manufacturer and ask for recommendations to prevent the alarm activation There are millions of batteries manufactured each year so it is impossible to guarantee consistent quality A defective battery will never become fully charged and may damage the charging circuits of...

Страница 8: ...________ _______________________________________________________________________________ _______________________________________________________________________________ _______________________________________________________________________________ _______________________________________________________________________________ _______________________________________________________________________...

Отзывы: