6
© Copyright 2020 Zoeller
®
Co. All rights reserved.
AQUANOT
®
FIT FLOAT SWITCH
FIGURE 3
SK3186
FIT CONTROLLER FUNCTIONS
There are two buttons on the front of the controller.
- Silence/Reset
• Can be pressed to silence current alarms for 24 hours.
•
Can be held for 3+ seconds to reset (or clear) alarms and LEDs. Flashing LEDs for conditions such as bad/disconnected battery or
power outage, for example, can’t be cleared by Silence/Reset. These conditions must be remedied to eliminate the LED indicator.
- Test
• Will run the pump to determine if amp draw of pump is within range.
•
Controller is factory programmed to self-test the pump for several seconds every 24 hours. This schedule may be modified once the
Fit is connected to the Z Control Cloud.
• Pressing the test button will start the 24-hour timer for self-testing.
- Test and Silence/Reset
•
Holding both buttons together for about 6 seconds will initiate a Factory Reset. This returns the firmware’s device configuration to
the state in which it left the factory. Any over the air firmware updates that have been installed will be retained.
Solid
Flashing
Off
System Ready
No Faults (Green)
AC off with No Faults
(Green)
--
Battery
Charged (Green)
Low Battery (Red)
No AC Power
Charging (Yellow)
Bad Battery (Red)
DC pump
Pump Ran
(Yellow)*
Pump Running (Yellow)
--
Pump Fault (Red)
Float Status
High Water (Red)
Float Fault (Red)
--
Z Control
Connected
Searching
Broadcasting SSID or Dormant
* Note: will not persist if pump didn’t pump water.
See also the laminated label affixed to the controller’s cord. This cord label also describes LED and
button functionality.
The LEDs will display information about the controller.
LOCKING PIN MUST BE
INSTALLED UNDER FLOAT
ROD IN THIS LOCATION.
MOLEX 2-PIN CONNECTOR
MOLEX 4-PIN CONNECTOR
DISCHARGE TEE
REDUCER FITTING
CLAMP
CHECK VALVE ASSEMBLY
CLAMP
PUMP O-RING
CHECK VALVE O-RING
DC PUMP
BULLHEAD DISCHARGE TEE
CLAMP
CHECK VALVE ASSEMBLY
CLAMP
PUMP O-RING
CHECK VALVE O-RING
DC PUMP
PROPAK SYSTEMS
COMBO SYSTEMS
SK2962
FIGURE 4
AQUANOT FIT
Note: Upper rubber stop is usually not needed.