RECOMMENDED INSTALLATION FOR ALL APPLICATIONS
1
2
3
4
6
7
8
9
10
11
12
13
14
5
Electrical wiring and protection must be in accordance with governing
electrical code and any other applicable local electrical requirements.
Install proper Zoeller unicheck (combination union and check valve),
preferably just above the basin to allow easy removal of the pump for
All installations require a basin cover to prevent debris from falling into
the basin and to prevent accidental injury.
When a Unicheck is installed, drill a 5 mm dia. hole in the discharge
pipe even with the top of the pump. The 50 and 90 Series pumps have
a built in vent hole.To avoid the water stream impact on the float
operation, the hole location should avoid facing the float.To reduce the
voice from water stream hitting basin, drill the hole below “off” point is
recommended.
NOTE: THE HOLE MUST
ALSO BE BELOW THE
BASIN COVER AND CLEANED PERIODICALLY.
(High Head unit see
#3 under “Caution” on front page). Water stream will be visible from
this hole during pump run periods.
mechanism(s).
Use full-size discharge pipe.
Basin must be in accordance with applicable codes and
before starting pump.
Basin must be clean and free of debris after installation.
Gate Valve or Ball Valve to be supplied by installer and installed
according to any and all codes.
“off” point is above the motor housing and positioned 180° from the
inlet. Never put “off” point below discharge on pump (Sewage &
NOTE: FOR AUTOMATIC PUMPS, USE
DEWATERING INSTALLATION SKETCH.
Gas tight seals required to contain gases and odors.
Vent gases and odors to the atmosphere through vent pipe.
STEP 1
STEP 2
Apply glue on every piping connection.
2” Pipe
Slip
Keep switch cable outside hose clamp.
Cover screw set
Vent fitting
Discharge fitting
Cord seal
Automatic pump
Reference range to
drill the 5 mm hole
Location to fix the float
(Basin 610x610 mm)
5
6
14
4
7
9
260 mm
(10-1/4”)
3
13
12
EA0053
EA0053
Vent
Discharge
Inlet hub
Cord seal
Length : 375 mm
(14-3/4")
For reference only
Basin cover has adhesive foam seal.
Содержание 910
Страница 21: ...1 4 2 3 5 6 8 9 7 10 11 4 12 13 3 14 21 1 5 5 1 2 3 4 A D Zoeller F G E B C 2019 Zoeller...
Страница 26: ...26 EA0095 U S Patent No 5 155 311 Canadian Patent No 2 060 748 20 170 mm 52 C 125 F 2019 Zoeller...
Страница 27: ...27 A C B 1 2 3 4 1 5 A 1 2 3 1 5 230 230 90 mm 260 mm 320 mm 2019 Zoeller A 1 2 3 4 5 B A...
Страница 31: ...31 2019 Zoeller 460x760 mm 2 5 6 4 7 9 1 2 EA0055 EA0055 5 mm 4 5 mm 45 1 2 3 4 5 180 6 7 8 9 10 11 12 13 14...
Страница 32: ...32 2019 Zoeller 3 13 3 12 12 12 EA0055 460x760 mm 5 mm 45 1 2 3 4 5 180 6 7 8 9 10 11 12 13 14...
Страница 33: ...460x760 mm 33 2019 Zoeller 4 2 2 13 8 2 11 9 550 mm EA0055 Top DN100 DN50 2 2 1 1 4 1 1 4 2 1 1 4 DN50 DN50...
Страница 34: ...4 DWV ABS Sch40 4 PVC Sch40 4 1 2 20 120 TOP A B 4 ABS PVC O Ring O Ring 4 1 2019 Zoeller 34...