See FM0531, FM0732 & FM1420 for alarms,
controls & junction boxes
SK291
TYPICAL SEWAGE INSTALLATION
SK290
TURN
OFF
TURN
ON
1
2
3
13
8
7
11
5
4
12
12
9
10
6
10 cm (4") OF GRAVEL
TYPICAL DEWATERING INSTALLATION
SK292
TURN
ON
TURN
OFF
1
2
3
7
9
14
8
6
4
5
10
12
13
10 cm (4") OF GRAVEL
MINIMUM
457mm X 610mm
(18"X24" BASIN.)
LARGER DEPTHS
MAY BE
REQUIRED.
TYPICAL EFFLUENT INSTALLATION
5
SEPTIC TANK
WW FILTER
DOSING CHAMBER
14
9
OFF
TURN
4
11
U.F. TYPE WIRE
GROUND LINE
SOURCE
TO AC
1
ON SITE DISPOSAL SYSTEM.
LEACHING FIELD, OR OTHER
MOUND SYSTEM, SAND FILTER,
TO LOW PRESSURE SYSTEM,
ALARM FLOAT
TURN
6
ON
2
15 10
3
17
16
8
All installations must comply with all applicable electrical and plumbing codes.
NOTE:
Double-seal pumps offer extra protection from damage caused by
seal failure.
RECOMMENDED INSTALLATION FOR ALL APPLICATIONS
(1) Electrical wiring and protection must be in accordance with governing
electrical codes.
(2) Install proper Zoeller unicheck (combination union and check valve),
preferably just above the basin to allow easy removal of the pump
for cleaning or repair.
(3) All installations require a basin cover to prevent debris from falling into
the basin and to prevent injury.
(4) When a Unicheck is installed, drill a 5 mm (3/16") diameter hole in the
discharge pipe even with the top of the pump.
NOTE: THE HOLE
MUST ALSO BE BELOW THE BASIN COVER AND CLEANED
PERIODICALLY.
(High Head unit see #4 under “Caution” on front page).
Water stream will be visible from this hole when pump is operating.
(5)
mechanism(s).
(6) Use full-size discharge pipe.
(7) Basin must be in accordance with governing codes and
(8)
before starting pump.
(9) Basin must be clean and free of debris after installation.
(10) Gate valve, shut-off valve or ball valve to be supplied by installer and
installed according to any and all codes.
(11)
“off”
point is above the motor housing and positioned 180° from the inlet.
Never put “off” point below discharge on pump.
(12) Gas tight seals required to contain gases and odors.
(13) Vent gases and odors to the atmosphere through vent pipe.
(14) Optional pump stand (P/N 10-2421) eliminates the need for blocks or
(15) Optional watertight control box available.
(16) For proper spacing of "On" - "Off" switches refer to local or
national standards and guildlines.
(17) Optional septic tank risers for easy access to pump, controls a
On some installations it may be desirable to install an independent hanger for the level control switches to avoid possible hang ups on the pumps,
SUGGESTED METHODS OF FLOAT INSTALLATION
TYPICAL FLOAT HANGER ON CONCRETE PITS
OR SEPTIC TANK RISERS
TYPICAL FLOAT HANGER ON STEEL COVER PITS
ACCESS COVER
STANDARD PIPE
FLANGE
PVC OR LIGHT WEIGHT
STAINLESS STEEL PIPE
PEA GRAVEL
TYPICAL FLOAT HANGER ON CONCRETE PITS
OR SEPTIC TANK RISERS
10-1457 FLOAT TREE
WITH 3 FLOATS SHOWN
SK1217
SK1218
- 17 -
© Copyright 2019 Zoeller Co. All rights reserved.
Содержание 910
Страница 21: ...1 4 2 3 5 6 8 9 7 10 11 4 12 13 3 14 21 1 5 5 1 2 3 4 A D Zoeller F G E B C 2019 Zoeller...
Страница 26: ...26 EA0095 U S Patent No 5 155 311 Canadian Patent No 2 060 748 20 170 mm 52 C 125 F 2019 Zoeller...
Страница 27: ...27 A C B 1 2 3 4 1 5 A 1 2 3 1 5 230 230 90 mm 260 mm 320 mm 2019 Zoeller A 1 2 3 4 5 B A...
Страница 31: ...31 2019 Zoeller 460x760 mm 2 5 6 4 7 9 1 2 EA0055 EA0055 5 mm 4 5 mm 45 1 2 3 4 5 180 6 7 8 9 10 11 12 13 14...
Страница 32: ...32 2019 Zoeller 3 13 3 12 12 12 EA0055 460x760 mm 5 mm 45 1 2 3 4 5 180 6 7 8 9 10 11 12 13 14...
Страница 33: ...460x760 mm 33 2019 Zoeller 4 2 2 13 8 2 11 9 550 mm EA0055 Top DN100 DN50 2 2 1 1 4 1 1 4 2 1 1 4 DN50 DN50...
Страница 34: ...4 DWV ABS Sch40 4 PVC Sch40 4 1 2 20 120 TOP A B 4 ABS PVC O Ring O Ring 4 1 2019 Zoeller 34...
Страница 37: ...SK1217 SK1218 37 2019 Zoeller FM0526 PVC 10 1457 3 3 L1 L2 1 2 L3 013071 006848 20 P N 10 0748...