Pump Wiring Instructions

  

  FOR YOUR PROTECTION, ALWAYS DISCONNECT THE PUMP FROM ITS POWER SOURCE BEFORE HANDLING.

  

 

 

 

All electrical connections must be wired and grounded in accordance with the National Electrical Code and all applicable  

 

 

 

local codes and or di nanc es.

  

 

 

 

“Risk of electrical shock”  

Do not remove the power supply cord and strain relief or connect conduit directly to pump.

 

 

 

Installation and checking of electrical circuits and hardware should be performed by a qualifi ed licensed electrician.

FIGURE 3A.  Models 810
and 815 Wiring Diagram

002397

10" MAX.

5" MIN.

FIGURE 2.  Pump Control Switch Installation

Use the di a gram above to secure the fl oat switch properly and obtain the proper tether to cus tom ize the on-off cycle to each application. Note the 
minimum off level shown above.  On Prepackaged Systems, the tether length is set at 5”.

Note: Failure to keep within proper teth er limits 
may pre vent reliable switch op er a tion.
Note: Cable must be mounted in hor i zon tal 
position.

Determining Pumping Range

in Inches (1 inch - 2.5 cm)

Use only as a guide. Due to weight 
of ca ble, pump ing range above 
hor i zon tal is not equal to pumping 
range be low hor i zon tal. Ranges are 
based on test ing in nonturbulent 
con di tions. Range may vary due to 
water tem per a ture and cord shape. As 
teth er length in creas es, so does the 
vari ance of the pump ing range.

Tether Length (inches) 

5 10

Pumping Range (GPM) 

9 13.5

min.

max.

SK305D

SK2651

ALARM FLOAT

FLOAT TREE

MIN. OFF

16"

FLOAT

PUMP CONTROL

Electrical Data

Amps

KVA

Code

Winding

Resistance

Line-to-Line

Model

BHP

RPM

Voltage

Phase

Hertz

Full Load

Shut Off

Locked

Rotor

E810

1

1725

230

1

60

6.0

6.0

24.5

G

2.3 / 2.0*

E815

2

1725

230

1

60

10.5

10.5

44.0

B

1.80 / 1.60*

*Line to line reading from the electrical load will only refl ect the run winding resistance. Start winding resistance can only be measured after 
removing the cover.

FIGURE 3B.  Models 810

and 815 Wiring Diagram

(932 Replacement Grinder System)

018929

RUN

O.L.

MOTOR

(3)

BLUE

RED

GREEN

START

(1)

(2)

YELLOW

BLUE

RED

CAPACITOR

(WHITE)

(BLACK)

(BROWN)

RED

BLACK

WHITE

Содержание 810

Страница 1: ...personal injury or property damage Warns of hazards that WILL cause serious personal injury death or major property damage Warns of hazards that CAN cause serious personal injury death or major proper...

Страница 2: ...bled basin package Page 5 shows a couple of the Prepackaged Systems Field Assembled Systems are discussed on page 3 4 Zoeller 810 and 815 Grinder Pumps can be retrofitted to existing positive displace...

Страница 3: ...onal 3 Pump motors are single phase Single phase motors require a run capacitor which is mounted in the the upper cap of the pump ref page 4 The units have an internal thermal overload 4 The 810 815 p...

Страница 4: ...switch operation Note Cable must be mounted in horizontal position Determining Pumping Range in Inches 1 inch 2 5 cm Use only as a guide Due to weight of cable pumping range above horizontal is not e...

Страница 5: ...limited to the National Electrical Code local regional and or state plumbing codes etc Typical Outdoor Grinder Pumping System Installations FIGURE 4A PACKAGED SYSTEM WITH FLEXIBLE HOSE DISCONNECT SK2...

Страница 6: ...nstructions found in this manual and located inside the panel enclosure 15 Remove any debris from the basin Using clean water check the system for proper operation 16 Seal and secure the lid using the...

Страница 7: ...material removed from the disc As a starting point remove shims of the same thickness as the amount machined from the cutter disc step 6 above Final running clearance must be between 0 007 and 0 012 B...

Страница 8: ...float switch held down or defective incorrect wiring in control panel water in cap assembly check valve not installed or malfunctioning Incorrect voltage impeller or cutter blocked negative head disc...

Отзывы: