Trouble Shooting Guide

A.  UNIT DOESN’T RUN.

B.  PUMP MAKES LOUD NOISES WHEN 

RUNNING.

C.  PUMP RUNS BUT DOES NOT PUMP 

LIQUID OUT.

D.  LIQUID DRAINS BACK INTO PUMP 

FROM DISCHARGE LINE.

E  LIQUID LEAKS FROM AROUND 

CHECK VALVE.

Pump not plugged in.

Low voltage; blown fuse, open circuit.

No condensate in reservoir.

Motor or wiring shorted.

Drain/Discharge line(s) blocked.

Debris in reservoir.

Float bound.

Maximum discharge height exceeded.

Discharge tube blocked.

Check Valve obstruction.

Check Valve damaged.

Check  Valve damaged.

Check Valve obstruction.

Highest point of discharge line is less 

than 5’.

Check Valve is too tight or too loose.

Plug in.

Have a qualified electrician check fuse circuit.

Be certain the appliance is generating 

condensate.  Check  drain  line(s)  and/or 

discharge line for blockage.

Contact Factory.

Check drain line(s) and/or discharge line for 

blockage.

Refer to “Maintenance Guidelines” section for 

cleaning instructions.

Refer  to  “Maintenance”  section  for  cleaning 

instructions.

Measure from bottom of pump to highest 

point. Rework discharge if height is greater 

that 18’. Refer to STEP 3 for guidelines.

Check discharge line for blockage, remove 

debris.

Refer  to  “Maintenance”  section  for  cleaning 

instructions.

Contact Factory.

Contact Factory.

Refer  to  “Maintenance”  section  for  cleaning 

instructions. 

Check valve may allow some condensate to 

drain out of line into reservoir. This is normal.

Check valve should be hand tight, then tighten 

an additional 1/2 turn with a 9/16” wrench.

 

Condition 

Possible Cause 

Remedy

 

Before servicing a pump, always shut off the main power 

breaker and then unplug the pump - making sure you are not standing in 

water and are wearing insulated, protective-sole shoes. Under flooded 

conditions, contact your local electric company or a qualified licensed electrician 

for disconnecting electrical service prior to pump removal. 

If the above checklist does not solve the problem, consult Zoeller Technical 

Service Department 1-(800) 928-PUMP - Do not attempt to service or otherwise 

disassemble pump.

Содержание 519

Страница 1: ...llationandusebeforeattemptingtheinstallation These materials should be retained for future reference 1 Check to be sure your power source is adequate to handle the amperage requirements of the motor as indicated on the pump or unit I D tag 2 All plumbing discharge and drain lines must be installed to meet local codes 3 This pump has been evaluated for use with water only 4 TESTING FOR GROUND As a ...

Страница 2: ...arbon derivatives oil gasoline solvents etc wash towels or feminine sanitary products etc or other abrasive or corrosive substances Limited Warranty This warranty is in lieu of all other warranties expressed or implied andwedonotauthorizeanyrepresentativeorother person to assume for us any other liability in connection with our products Contact Zoeller Pump Company 3649 Cane Run Road Louisville Ke...

Страница 3: ... ground fault protected circuit DO NOT ever cut splice or damage power cord DO NOT carry or lift pump by its power cord DO NOT use an extension cord with this condensate pump Ten Helpful Hints or Easy Installation Do s and Do Nots or Installing Unit 5 DO NOT use a discharge pipe smaller than the pump discharge size 6 DO test pump immediately after installation to be sure that the system is working...

Страница 4: ...downward slope to allow for gravity flow Note Local codes may require the use of a condensate neutralizer when using this pump Note Make sure the drain lines from the A C condenser are supported above the reservoir and no weight from the drain line is directed to the bottom of the reservoir SK3177 SK1765 SK3178 STEP 1 Mounting Location STEP 2 Installation of Condensate Drain Lines CONDENSING GAS F...

Страница 5: ...Kink or Pinch off blocking flow Figure 3 1 SK3179 STEP 3 Installation of Discharge Line STEP 4 Installation of Safety Switch GFCI Outlet Pipe Supports To Main Drain Floor Joists 15 FT Max RECOMMENDED NOT INCLUDED HOSE CLAMP 3 8 IDTubing Inverted U Note Condensate Drain Lines not Shown Refer to Step 2 for Installation of Drain Lines POWER CORD SAFETY SWITCH LEADS INLETS 4 MOUNTING BRACKET 2 DISCHAR...

Страница 6: ...houldactivate breakingthethermostatcircuittotheappliance 4 Plug the pump in and allow the pump to empty the tank As the water level decreases the appliance will reset STEP 5 Testing of Pump Operation Maintenance Guidelines Cleaning of Reservoir 1 Remove entire pump from wall if mounted 2 Disassemble reservoir from the deck by inserting a screwdriver in either side of the deck 3 Clean reservoir as ...

Страница 7: ...elines section for cleaning instructions Refer to Maintenance section for cleaning instructions Measure from bottom of pump to highest point Rework discharge if height is greater that 18 Refer to STEP 3 for guidelines Check discharge line for blockage remove debris Refer to Maintenance section for cleaning instructions Contact Factory Contact Factory Refer to Maintenance section for cleaning instr...

Страница 8: ...8 Zoeller Co All rights reserved MAILTO P O BOX 16347 Louisville KY 40256 0347 SHIPTO 3649 Cane Run Road Louisville KY 40211 1961 502 778 2731 1 800 928 PUMP FAX 502 774 3624 Visit our web site zoellerpumps com NOTES ...

Отзывы: