background image

3

© Copyright 2014 Zoeller Co. All rights reserved.

MODELS:

507-C

507-D

507-E

507-F

ITEM DESCRIPTION

QTY

4/96

thru

10/05

11/05

thru

9/11

10/11

thru

10/13

11/13

thru

Current

DC backup pump

1

010475

017198

017198

017198

Plastic battery box and cover

1

10-0764

10-0764

10-0764

10-0764

DC control charger with terminals

1

152899

152899

152899

152899

“Off”/”On” float switch

1

017197

017197

017197

017197

1½" x 5" long PVC pipe nipple

1

005639

N/A

N/A

N/A

Check valve

(2) REV C - (1) REV D

005636

005636

019768

019768

Reducer hose coupling and clamp

1

30-0188

N/A

N/A

N/A

1¼" x 1" PVC reducer fitting

1

005642

N/A

N/A

N/A

1" pipe to hose adapter elbow

1

005643

N/A

N/A

N/A

10 

1" hose coupling and two clamps

1

005703

N/A

N/A

N/A

11 

1½" PVC pipe tee

1

005645

005645

005645

005645

12 

1½" 90 degree PVC pipe elbow

1

005644

N/A

N/A

N/A

13

1¼" x 1¼" PVC coupling

1

009129

N/A

N/A

N/A

14 

Pump mounting kit, includes brkt, S.S. worm drive 

clamp, two #10-24 screws and washers.

1

005704

N/A

N/A

N/A

15

Cable tie

1

005868

N/A

N/A

N/A

16

Anchors, wall

2

009691

009691

009691

N/A

17

Bracket, control mounting

1

007779

007779

007779

N/A

18

1½" x 1½" PVC coupling

1

N/A

009746

N/A

N/A

19

Clamp, H28 SS / zinc-plated screw

1

012724

012724

012724

012724

20

Fuse, AGC - 15 amp

1

N/A

012352

012352

012352

REPLACEMENT PARTS LIST

The DC emergency pump is designed as a backup to your primary sump pump during unexpected power outages or primary pump failure. The 

DC pump, electronic controls and all the parts required for installation are included except the battery which is supplied by the user. The system 

is designed for installation in sumps with minimum of 18" diameter and 24" deep. For 18" x 22" applications, consult factory.

DESCRIPTION

TROUBLESHOOTING INFORMATION, 

continued

7.  Alarm sounds during battery recharge cycle.

  (a)  Push alarm reset (max. 3 times). If condition persists, replace battery.

  (b)  To silence alarm if alarm will not reset, unplug the charger from 

115V wall outlet, then disconnect the black lead from charger on 

negative (-) battery post. Check battery. Replace if necessary. 

Reconnect and refer to Installation (step 12).

2

12 VOLT BATTERY

SUPPLIED BY USER

1

19

4

20

3

6

11

SK2981

The DC emergency pump system requires a good quality, 12 volt 

battery to obtain maximum pumping time during a power outage. 

A deep-cycle, 12 volt, 105 amp-hour marine battery or larger is 

recommended and will provide approximately 7½ hours of continuous 

pumping time in a sump pump installation with 8' of head pressure.  In 

most installations the pump runs intermittently and the battery life is 

extended accordingly.  Batteries with top terminals are recommended 

for ease of installation. These batteries contain acid and proper 

precaution must be taken when handling. Maximum battery size 

13½" length x 7" width x 9½" height.

BATTERY SELECTION

Содержание 507-0005

Страница 1: ...state of California to cause cancer and birth defects or other reproductive harm 1 Make sure there is a properly grounded 115V receptacle available Do not use primary pump circuit The location must b...

Страница 2: ...chased and used as a backup to a primary dewatering system A complete system includes a Model 507 Basement Sentry and an Aquanot Battery 1 Inspectandtestthesystemforproperoperationsatleastevery3months...

Страница 3: ...e DC emergency pump is designed as a backup to your primary sump pump during unexpected power outages or primary pump failure The DC pump electronic controls and all the parts required for installatio...

Страница 4: ...DC pump and measure between the in line check valve and tee Use that measurement to cut discharge pipe Solvent weld that piece first to the tee Measure cut solvent weld any remaining discharge piping...

Страница 5: ...PRESENT IN MAIN DISCHARGE LINE SEE PUMP INSTALLATION INSTRUCTIONS BATTERY BOX BATTERY BOX OUTLET PRIMARY PUMP IMPORTANT OFF LEVEL OF FLOAT ASSEMBLY MUST BE HIGHER THAN DC BACKUP PUMP 1 MIN SK2499 SK25...

Страница 6: ...SUPPLIED BY USER DC BACK UP PUMP CLAMP FLOAT SWITCH WHITE LEAD TO POSITIVE BLACK LEAD TO POSITIVE WHITE LEAD TO DC PUMP BLACK LEAD TO NEGATIVE 15 AMP FUSE DC CHARGER BLACK LEAD TO NEGATIVE TO FLOAT S...

Страница 7: ...D will always display the battery voltage and current going to the battery if charging The alarm screen shows current alarms The cycle counter screen shows how many times the DC float has been activat...

Страница 8: ...the CO detector to activate Contact the manufacturer and ask for recommendations as to what can be done to prevent the alarm activation MAIL TO P O BOX 16347 Louisville KY 40256 0347 SHIP TO 3649 Can...

Отзывы: