Please read and understand this entire manual before attempting to assemble, operate, or install the 

product. 

•  NOTE

: Pumps with the “UL” Mark and pumps with the “US” mark are tested to UL Standard 

UL778. CSA certified pumps are certified to CSA Standard C22.2 No. 108. (CUS.)

•  ELECTRICAL SHOCK ALERT. 

 

To reduce the risk of electric shock, install only a circuit protected by a ground-fault circuit-interruptor 

(GFCI). Make certain that the ground fault receptacle is within the reach of the pump’s power supply 

cord. DO NOT USE AN EXTENSION CORD. 

•  ELECTRICAL SHOCK ALERT.

  

Follow all local electrical and safety codes, as well as the National Electrical Code (NEC) and the 

Occupational Safety and Health Act (OSHA).

•  ELECTRICAL SHOCK ALERT.

  

Do not kink power cable, and never allow the cable to come in contact with oil, grease, hot surfaces, 

chemicals, or sharp objects. Replace damaged or worn wiring cord immediately.

•  ELECTRICAL SHOCK ALERT.

 

As a safety measure, each electrical outlet should be checked for ground using an Underwriters 

Laboratory Listed circuit analyzer, which will indicate if the power, neutral, and ground wires are 

correctly connected to your outlet. If they are not, contact a licensed electrician.   

•  ELECTRICAL SHOCK ALERT.

 

These pumps are supplied with a 3-prong grounded plug to help protect you against the possibility of 

electrical shock. DO NOT UNDER ANY CIRCUMSTANCES REMOVE THE GROUND PIN.

•  ELECTRICAL SHOCK ALERT.

 

To reduce the risk of electric shock, install only a circuit protected by a ground-fault circuit-interruptor 

(GFCI).

•  ELECTRICAL SHOCK ALERT.

 

Make sure the pump electrical supply circuit is equipped with fuses or circuit breakers of proper 

capacity.  A separate branch circuit is recommended, sized according the National Electrical Code 

for the current shown on the pump name plate.

•  CHEMICAL ALERT.

 

 

Prop65 Warning for California residents: WARNING: Cancer and Reproductive Harm - 

 

 www.P65Warnings.ca.gov

CAUTION

CAUTION

•  PRODUCT DAMAGE MAY RESULT.

 

Make certain that the power source conforms to the requirements of your equipment.

•  PRODUCT DAMAGE MAY RESULT.

 

Maximum continuous operating water temperature for standard model pumps must not exceed 

104°F (40°C).

  

SAFETY INFORMATION

DANGER

•  ELECTRICAL SHOCK HAZARD. 

Always disconnect power source before performing any work on or near the motor or its connected 

load.  If the power disconnect point is out-of-sight, lock it in the open position and tag it to prevent 

unexpected application of power.  Failure to do so could result in fatal electrical shock.

•  ELECTRICAL SHOCK HAZARD. 

Do not handle the pump with wet hands or when standing in water as fatal electrical shock could 

occur.  Disconnect main power before handling unit for ANY REASON!

•  RISK OF ELECTRIC SHOCK.  

These pumps have not been investigated for use in swimming pool areas.

WARNING

Before beginning installation of product, make sure all parts are present. Compare parts with package 

contents list. If any part is missing or damaged, do not attempt to assemble the product. 

Estimated Installation Time: 

2 hours

Tools Required for Assembly (not included):

 Adjustable wrench, hacksaw, flathead screwdriver, 

Phillips screwdriver, tape measure, utility knife, pipe wrench.

Description

Quantity

Pump

1

PREPARATION

Parts Required For Assembly (not included): 

sewage pump basin minimum 18 in. w x 30 in. deep, 

basin cover, basin gasket, 2 in. check valve, 2 in. union, gate valve or ball valve as required by codes, 2 

in. Sched 40 PVC pipe, 2-step PVC glue system (primer and sealer), 

cable or zip ties.

PACKAGE CONTENTS

Содержание 1263

Страница 1: ...se Date Zoeller is a registered trademark of Zoeller Co All Rights Reserved Questions problems missing parts Before returning to your retailer call our customer service department at 1 800 584 8089 7 30 a m 5 00 p m EST Monday Friday ATTACH YOUR RECEIPT HERE SW1316 B ZoellerAtHome com ...

Страница 2: ... or circuit breakers of proper capacity A separate branch circuit is recommended sized according the National Electrical Code for the current shown on the pump name plate CHEMICAL ALERT Prop65 Warning for California residents WARNING Cancer and Reproductive Harm www P65Warnings ca gov CAUTION CAUTION PRODUCT DAMAGE MAY RESULT Make certain that the power source conforms to the requirements of your ...

Страница 3: ...k Main waste line to sewer or septic tank Switch Pump 1 2 These pumps are equipped with a float switch The pump will turn on automatically when the water level in the basin reaches the on level On 2 Off 3 Item On Level Off Level 1263 10 25 in 5 in 3 The pump will turn off automatically when the water level in the basin reaches the off level GENERAL PUMP INFORMATION INSTALLATION INSTRUCTIONS 30 in ...

Страница 4: ...codes Incoming water Switch Switch 1 in Minimum Discharge Pipe INSTALLATION INSTRUCTIONS 7 Use a 2 step PVC glue system not included to join pipe and any fittings needed 8 Drill a 3 16 in hole in the discharge pipe above the pump discharge to prevent air lock Pumps have a vent located in the pump but an additional vent hole is recommeded Water stream will be visible from this hole when the pump is...

Страница 5: ...o sewer or septic tank Check Valve Gate Valve Main waste line 10 11 12 INSTALLATION INSTRUCTIONS 13 Attach power supply cord to discharge pipe using cable or zip ties not included to allow the float switch to move freely 14 Connect pump power supply cord to a receptacle protected by a ground fault circuit interruptor GFCI Cable or Zip Ties GFCI protected receptacle 13 14 15 Fill the basin with wat...

Страница 6: ...ree motion of switch Pump starts and stops too often 1 Water is back flowing into basin from discharge pipe 1 Install check valve 2 Switch is defective 2 Replace switch 3 Check valve not functioning properly or leaking 3 Be sure check valve is installed and operating properly Replace check valve if necessary Pump shuts off and turns on independently of switch trips thermal overload protection 1 Ex...

Страница 7: ...intain the unit in accordance with printed instructions provided b to failures resulting from abuse accident or negligence or use of inappropriate chemicals or additives in the water c to normal maintenance services and the parts used in connection with such service d to units which are not installed in accordance with normal applicable local codes ordinances and good trade practices and e if the ...

Страница 8: ...15 mounting screw M4 0 7x6 case o ring 115x4 NBR 3 Base Kit 025388 Includes pump base screws M5 0 8x15 4 Cap Kit 025385 Includes cap screws M6 1 0x15 GND screw M4 0 7x6 0 case o ring 115x4 NBR cap with handle guard and plug nameplate screw M3x1 34 switch to case screws switch 5 Float Kit 025381 Includes guide rod guide strap float REPAIR PARTS WIRING DIAGRAM 3 L1 L2 1 2 1 2 3 4 RUN O L MOTOR BLUE ...

Страница 9: ...16 2020 All rights reserved ...

Отзывы: