background image

17

WARRANTY

This product is warranted for one (1) year from the date of purchase or two (2) years from the date of 

manufacture, whichever occurs first.  Subject to the conditions hereinafter set forth, the manufacturer 

will repair or replace to the original consumer, any portion of the product which proves defective due 

to defective materials or workmanship. To obtain warranty service, contact the dealer from whom the 

product was purchased. The manufacturer retains the sole right and option to determine whether to 

repair or replace defective equipment, parts or components. Damage due to conditions beyond the 

control of the manufacturer is not covered by this warranty. For warranty questions or service, call 

1-866-994-4148.

THIS WARRANTY WILL NOT APPLY: (a) To defects or malfunctions resulting from failure to properly 

install, operate or maintain the unit in accordance with printed instructions provided; (b) to failures 

resulting from abuse, accident or negligence; (c) to normal maintenance services and the parts used in 

connection with such service; (d) to units which are not installed in accordance with normal applicable 

local codes, ordinances and good trade practices; and (e) if the unit is used for purposes other than for 

what it was designed and manufactured.
RETURN OF WARRANTED COMPONENTS: Any item to be repaired or replaced under this warranty 

must be returned to the manufacturer at such place as the manufacturer may designate, freight prepaid.
THE WARRANTY PROVIDED HEREIN IS IN LIEU OF ALL OTHER EXPRESS WARRANTIES, 

AND MAY NOT BE EXTENDED OR MODIFIED BY ANYONE. ANY IMPLIED WARRANTIES SHALL 

BE LIMITED TO THE PERIOD OF THE LIMITED WARRANTY AND THEREAFTER ALL SUCH 

IMPLIED WARRANTIES ARE DISCLAIMED AND EXCLUDED. THE MANUFACTURER SHALL 

NOT, UNDER ANY CIRCUMSTANCES, BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL OR 

SPECIAL DAMAGES, SUCH AS, BUT NOT LIMITED TO, DAMAGE TO, OR LOSS OF, OTHER 

PROPERTY OR EQUIPMENT, LOSS OF PROFITS, INCONVENIENCE , OR OTHER INCIDENTAL 

OR CONSEQUENTIAL DAMAGES OF ANY TYPE OR NATURE. THE LIABILITY OF THE 

MANUFACTURER SHALL NOT EXCEED THE PRICE OF THE PRODUCT UPON WHICH SUCH 

LIABILITY  IS BASED.
This warranty gives you specific legal rights, and you may have other rights which vary from state to 

state. Some states do not allow limitations on duration of implied warranties or exclusion of incidental or 

consequential damages, so the above limitations may not apply to you.

In those instances where damages are incurred as a result of an alleged pump failure, the 

Homeowner must retain possession of the pump for investigation purposes.

Содержание 1104-0082

Страница 1: ...in basin Zoeller is a registered trademark of Zoeller Co All Rights Reserved Serial Number Purchase Date Questions problems missing parts Before returning to your retailer call our customer service department at 1 800 584 8089 7 30 a m 5 00 p m EST Monday Friday ATTACH YOUR RECEIPT HERE ...

Страница 2: ...h of the pump s power supply cord DO NOT USE AN EXTENSION CORD ELECTRICAL SHOCK ALERT Follow all local electrical and safety codes as well as the National Electrical Code NEC and the Occupational Safety and Health Act OSHA ELECTRICAL SHOCK ALERT Do not kink power cable and never allow the cable to come in contact with oil grease hot surfaces chemicals or sharp objects Replace damaged or worn wirin...

Страница 3: ... pumps must not exceed 110 F 43 C PRODUCT DAMAGE MAY RESULT Do not use an automatic plumbing vent device such as a Pro Vent Some states require this product to be installed by a licensed plumber Part Description Quantity A Pre Assembled Pump System Includes B through H 1 B Basin 1 C Pump 1 D Check Valve 1 E Basin Lid 1 F Cord Seal 1 G Inlet Cap and Seal 1 H Foam Gasket 1 PACKAGE CONTENTS A E F D C...

Страница 4: ...VC glue system primer and sealer Parts Required For Standard Assembly not included 2 in slip by NPT coupling 1 1 2 in slip by NPT coupling drain pipe compression fitting for 1 1 4 in drain pipe PVC pipe and fittings as required to complete installation additional check valve as required by codes 1 Wet bar sink pump GENERAL PUMP USES 2 Laundry tray pump Laundry Tray Sink Washer Vent Pipe Inlet Pipe...

Страница 5: ...scharge Pipe 3 3 Softener discharge pump Inlet Pipe Vent Pipe Discharge Pipe 4 4 Dehumidifier pump INSTALLATION INSTRUCTIONS Vent Opening 1 Thread 2 in coupling not included into the vent opening on the top of the pre assembled pump system 1 ...

Страница 6: ... rigid 2 in vent pipe not included to the vent pipe coupling according to local regional and state codes 4 Attach rigid 1 1 2 in discharge pipe not included to the discharge pipe coupling according to local regional and state codes Plumb into existing drain pipe per local regional and state codes Use check valve not included as required by codes ...

Страница 7: ... for standard installation pre assembled pump system can be installed directly under a sink using an internal trap not included NOTE Check local and state codes before using the internal trap option 4 in min Internal trap 1 4 in min Plus 4 1 2 in Tailpipe 2 Place the pre assembled pump system beneath the sink and measure the distance between the sink inlet and the basin lid Minimum distance is 4 i...

Страница 8: ...eal F and basin lid E 4 5 5 Remove black inlet cap and o ring G from basin lid E and screw it onto the inlet opening on the side of the basin B Side Inlet Opening B 3 Cut a tailpipe not included to the total pipe length in step 2 X 4 in min 4 1 2 in Tailpipe Length 3 E F E G G ...

Страница 9: ...losest to the pump float and the trap discharge is against the wall of the basin B Trap Inlet Internal Trap Discharge Inside Basin Pre Assembled Pump System Top View Inlet Opening in Lid Cord Opening in Lid Vent Opening in Lid Discharge Opening in Lid Pump Discharge Pump Float 7 Thread 1 1 4 in compression fitting not included onto the tailpipe from step 3 Insert the tailpipe into the inlet openin...

Страница 10: ...y 10 Place the basin lid E trap assembly from step 7 on top of the basin B making sure the foam gasket H is firmly in place Screw in the 8 bolts removed in step 3 10 Cord Seal Opening 11 Pull excess power cord through the cord seal F opening and reinstall the cord seal F Make sure the o ring is seated in the seal before reinstallation 11 E B F H ...

Страница 11: ... opening on the top of the basin B 12 B 14 14 Attach rigid 2 in vent pipe not included to the vent pipe coupling according to local regional and state codes 13 Thread 1 1 2 in coupling not included into the discharge opening at the top of the basin B 13 B ...

Страница 12: ...cording to local regional and state codes Plumb into existing drain pipe per local regional and state codes Use additional check valve not included as required by codes 16 Connect inlet pipe not included to appliance according to local regional and state codes Discharge Pipe Vent Pipe Inlet Pipe ...

Страница 13: ...gional and state codes Use additional check valve not included as required by codes 2 Connect pump power supply cord to a receptacle protected by a ground fault circuit interrupter GFCI 3 Fill the basin B with water to check operation The pump will start when the water level has reached the switch on level Discharge Pipe Vent Pipe Inlet Pipe Main Waste Line GFCI Protected Receptacle On Level B ...

Страница 14: ...ll check valve 2 Switch is defective 2 Replace switch 3 Check valve not functioning properly or leaking 3 Be sure check valve is installed and operating properly Replace check valve if necessary 4 Float is too tight on float rod 4 Clean debris build up off float rod 5 Overload is open 5 Allow motor to cool and overload to reset Pump will not shut off 1 Switch is defective 1 Replace switch 2 Switch...

Страница 15: ... 5 38 10 30 15 14 SPECIFICATIONS Problem Possible Cause Corrective Action Capacity or flow drops after a period of use 1 Clogged inlet or discharge pipe 1 Clean all piping 2 Check valve clogged or defective 2 Be sure check valve is installed and operating properly Replace check valve if necessary 3 Abrasive material or chemicals damaged impeller or pump housing 3 Remove base and inspect TROUBLESHO...

Страница 16: ...Inspect and test system for proper operation at least every three months 1 Remove any build up of debris from the switch or float and check to be sure it moves freely Debris on Float 1 Debris in Basin 2 2 Remove any debris from the basin that could interfere with the operation of the switch ...

Страница 17: ...the unit is used for purposes other than for what it was designed and manufactured RETURN OF WARRANTED COMPONENTS Any item to be repaired or replaced under this warranty must be returned to the manufacturer at such place as the manufacturer may designate freight prepaid THE WARRANTY PROVIDED HEREIN IS IN LIEU OF ALL OTHER EXPRESS WARRANTIES AND MAY NOT BE EXTENDED OR MODIFIED BY ANYONE ANY IMPLIED...

Страница 18: ...or replacement parts call our customer service department at 1 800 584 8089 8 a m 8 p m EST Monday Friday E F D C B PART DESCRIPTION PART NO B Basin 013017 C Pump 152289A D Check Valve 019768 E Basin Lid 013018 F Cord Seal 006018 ...

Отзывы: