background image

2

© Copyright 2017 Zoeller

®

 Co. All rights reserved.

Manufacturer warrants, to the purchaser and subsequent owner dur-

ing the warranty period, every new product to be free from defects 

in material and workmanship under normal use and service, when 

properly used and maintained, for a period of one year from date of 

purchase by the end user, or 18 months from date of original manu-

facture of the product, whichever comes first.  Parts that fail within 

the warranty period, one year from date of purchase by the end user, 

or 18 months from the date of original manufacture of the product, 

whichever comes first, that inspections determine to be defective in 

material or workmanship, will be repaired, replaced or remanufactured 

at Manufacturer's option, provided however, that by so doing we will 

not be obligated to replace an entire assembly, the entire mechanism 

or the complete unit.  No allowance will be made for shipping charges, 

damages, labor or other charges that may occur due to product failure, 

repair or replacement.

This warranty does not apply to and there shall be no warranty for 

any material or product that has been disassembled without prior ap-

proval of Manufacturer, subjected to misuse, misapplication, neglect, 

alteration, accident or act of God; that has not been installed, operated 

or maintained in accordance with Manufacturer's installation instruc-

tions; that has been exposed to outside substances including but not 

limited to the following:  sand, gravel, cement, mud, tar, hydrocarbons, 

hydrocarbon derivatives (oil, gasoline, solvents, etc.), or other abrasive 

or corrosive substances, wash towels or feminine sanitary products, 

etc. in all pumping applications.  The warranty set out in the paragraph 

above is in lieu of all other warranties expressed or implied; and we 

do not authorize any representative or other person to assume for us 

any other liability in connection with our products.

Contact Manufacturer at, 3649 Cane Run Road, Louisville, Kentucky  

40211, Attention: Customer Service Department to obtain any needed 

repair or replacement of part(s) or additional information pertaining 

to our warranty.

MANUFACTURER EXPRESSLY DISCLAIMS LIABILITY FOR SPE-

CIAL, CONSEQUENTIAL OR INCIDENTAL DAMAGES OR BREACH 

OF EXPRESSED OR IMPLIED WARRANTY; AND ANY IMPLIED 

WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE AND 

OF MERCHANTABILITY SHALL BE LIMITED TO THE DURATION 

OF THE EXPRESSED WARRANTY.

Some states do not allow limitations on the duration of an implied 

warranty, so the above limitation may not apply to you. Some states 

do not allow the exclusion or limitation of incidental or consequential 

damages, so the above limitation or exclusion may not apply to you.

This warranty gives you specific legal rights and you may also have 

other rights which vary from state to state.

Limited Warranty

  ELECTRICAL PRECAUTIONS-

 Before servicing a pump, always shut off the main power breaker and then unplug the pump - mak-

ing sure you are not standing in water and wearing insulated protective sole shoes. Under flooded conditions, contact your local electric company or a 
qualified licensed electrician for disconnecting electrical service prior to pump removal.

 

Submersible pumps can become pressurized under normal operating conditions — allow 2-1/2 hours after disconnecting before attempting service.

CONDITION
A.   Pump will not start or run.   

B.   Motor overheats and trips overload 

or blows fuse.

C.   Pump starts and stops too often.

D.   Pump will not shut off. 
E.   Pump operates but delivers little 

or no water. 

F.  Drop in head and/or capacity after 

a period of use. 

G.  If tank or fittings leak.

If the above checklist does not uncover the problem, consult the factory - Do not attempt to service or otherwise disassemble pump. Service must 

be by Zoeller Authorized Service Stations.

Service Checklist

COMMON CAUSES

Check fuse, low voltage, overload open, open or incorrect wiring, open switch, impeller or seal bound mechani-
cally, defective capacitor or relay when used, motor or wiring shorted. Float assembly held down. Switch defective, 
damaged, or out of adjustment.
Incorrect voltage, negative head (discharge open lower than normal) impeller or seal bound mechanically, defec-
tive capacitor or relay, motor shorted.
Float too tight on rod, check valve stuck, or none installed in long distance line, overload open, switch
defective.

Debris under float assembly, float or float rod bound by basin sides or other, switch defective, damaged or out of adjustment.

Check strainer housing, discharge pipe, or if check valve is used, the vent hole must be clear. Discharge head 
exceeds pump capacity. Low or incorrect voltage. Incorrect motor rotation. Capacitor defective. Incoming water 
containing air or causing air to enter pumping chamber.
Increased pipe friction, clogged line or check valve. Abrasive material and adverse chemicals could possibly 
deteriorate impeller and pump housing. Check line. Remove base and inspect.
Carefully tighten pipe joints (use pipe dope) and screws. Check gasket location, tighten lid evenly. Do not over 

tighten fittings or screws.

Содержание 105

Страница 1: ...o reduce the risk of electrical shock a properly grounded receptacle of grounding type must be installed and protected by a ground fault circuit interrupter GFCI in accordance with national electrical code and local codes 6 Installation and checking of electrical circuits and hardware should only be performed by a qualified licensed electrician 7 Risk of electric shock These pumps have not been in...

Страница 2: ...ow limitations on the duration of an implied warranty so the above limitation may not apply to you Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from state to state Limited Warranty ELECTRICAL PRECAUTIONS...

Страница 3: ...ontact dealer if unit appears to be damaged 3 DO clean all debris from the basin and pump 4 DO always disconnect pump from power source before handling DO always connect to a separately protected and properly grounded ground fault protected circuit DO NOT ever cut splice or damage power cord DO NOT carry or lift pump by its power cord DO NOT use an extension cord Do s And Don t s For Installing A ...

Страница 4: ... side standard IMPORTANT Check local and state codes before using the internal trap option 1 1 Figure 1 1A and 1 1B are typical configurations for installation of the drain systems The actual configuration will vary depending on your cabinet and sink configuration NOTE If installing the internal trap record the x dimension it will be required in Step 4 INTERNAL TRAP COMPONENTS SUPPLIED BY OTHERS F...

Страница 5: ...ARD THE FLOAT Water stream will be visible from this hole during pump run periods IMPORTANT DISCHARGE PIPE PUMP DISCHARGE WEEP HOLE SK2002 STEP 3 Installation of the Gasket 3 1 Install the gasket into the gasket seat at the top of the basin Figure 3 1 SK3160 OVERLAP DETAIL GASKET SEAT FOAM GASKET GASKET SEAT DETAIL FOAM GASKET APPROXIMATELY 1 4 OVERLAP BASIN ...

Страница 6: ...stallation Only 4 1 Cut the tailpipe to the dimension determined in Figure 4 1 4 2 Install the sink drain components to the lid as shown in Figure 4 2 4 3 Orient the lid assembly as shown in Figure 4 3 and secure the trap components HAND TIGHTEN the assembly to the lid at this time Adjustment will be required in Step 5 Note To ensure a proper water seal the extension must be installed as shown in ...

Страница 7: ...LATION STEP 5 Final Assembly NOTE External plumbing configuration will vary depending on the location of basin location of main stack and available space 5 1 Place the pump in the basin as shown in Figure 5 1 NOTE If installing the internal trap rotate the tail pipe to the orientation shown in Figure 5 1 5 2 Install the lid components as shown in Figure 5 2 NOTE Pull excess cordage through the ope...

Страница 8: ...13 2 Basin Tank 1 013017 013017 3 Discharge 1 013732 N A 4 Basin Lid 1 013018 013018 A 5 Hardware pack seal 1 154256 154256 6 Unicheck 1 30 0181 30 0181 Notes 1 Hardware pack consist of 8 1 4 20 x 1 1 8 long round head stainless steel machine screws 8 1 4 20 stainless steel hex nuts and 16 1 4 flat stainless steel washers along with 1 pipe cap and 1 o ring and 1 pipe seal Copyright 2017 Zoeller Co...

Отзывы: