  STEP 6 

Initial Testing of Drain Basin System

 

6.1)  Plug the cord into a properly grounded GFCI receptacle.

  6.2)  Fill tank with water.

  

 

  6.3)  Check all plumbing for leaks as the basin fills.
  6.4)  Verify that the pump starts and stops.
  6.5.)  Check the discharge line for leaks as the pump empties the basin.
  6.6.)  Repeat steps 6.2 to 6.5 as necessary to insure proper operation.
  6.7.)  If problems persist refer to the troubleshooting guide located on page 2 of this manual.

KEY 

TRAP INLET 

GFCI

OUTLET

GFCI

OUTLET

CORD SEAL

CAP

UNION

(PURCHASED SEPARATELY)

CHECK VALVE

DISCHARGE PIPE

DISCHARGE PIPE

CHECK VALVE

CAP

UNION

(PURCHASED SEPARATELY)

CORD SEAL

INLET

INLET

INTERNAL TRAP INSTALLATION

STANDARD INSTALLATION

  STEP 5 

Final Assembly

 

NOTE:  External plumbing configuration will vary depending on the location of  basin, location of  main stack and    

available space.

 

5.1) 

Place the pump in the basin as shown in Figure 5.1.

 

  NOTE: If installing the internal trap, rotate the tail pipe to the orientation shown in Figure 5.1.

 

  5.2) 

Install the lid components as shown in Figure 5.2.

  

 

 

NOTE:  Pull excess cordage through the opening and install the cordseal as shown in Figure 5.3A. 

   

Ensure o-ring is in the cap before installation.

  5.3) 

Place the basin assembly in its final position and complete plumbing. Secure all connections 

   

(shown  in 5.3A or 5.3B).

Figure 5.1

Figure 5.2

SK2005

SK2007A

Figure 5.3A

Figure 5.3B

SK2006

1/4-20 x 1-1/8"

S.S. SCREWS

1/4-20 STD.

S.S. FLAT WASHERS

DISCHARGE PIPE

1 1/2" SLP x NPT

2" SLP x NPT

CORD SEAL

1/4-20 

S.S. NUTS

1/4-20 STD.

S.S. FLAT WASHERS

(TORQUE TO 35 IN-LB)

SEE NOTE

(APPLY SEALANT TO THREADS)

CAP

O-RING

O-RING

CAP

CAP SECTION VIEW

Содержание 105

Страница 1: ...o reduce the risk of electrical shock a properly grounded receptacle of grounding type must be installed and protected by a ground fault circuit interrupter GFCI in accordance with national electrical code and local codes 6 Installation and checking of electrical circuits and hardware should only be performed by a qualified licensed electrician 7 Risk of electric shock These pumps have not been in...

Страница 2: ...ow limitations on the duration of an implied warranty so the above limitation may not apply to you Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from state to state Limited Warranty ELECTRICAL PRECAUTIONS...

Страница 3: ...ontact dealer if unit appears to be damaged 3 DO clean all debris from the basin and pump 4 DO always disconnect pump from power source before handling DO always connect to a separately protected and properly grounded ground fault protected circuit DO NOT ever cut splice or damage power cord DO NOT carry or lift pump by its power cord DO NOT use an extension cord Do s And Don t s For Installing A ...

Страница 4: ... side standard IMPORTANT Check local and state codes before using the internal trap option 1 1 Figure 1 1A and 1 1B are typical configurations for installation of the drain systems The actual configuration will vary depending on your cabinet and sink configuration NOTE If installing the internal trap record the x dimension it will be required in Step 4 INTERNAL TRAP COMPONENTS SUPPLIED BY OTHERS F...

Страница 5: ...ARD THE FLOAT Water stream will be visible from this hole during pump run periods IMPORTANT DISCHARGE PIPE PUMP DISCHARGE WEEP HOLE SK2002 STEP 3 Installation of the Gasket 3 1 Install the gasket into the gasket seat at the top of the basin Figure 3 1 SK3160 OVERLAP DETAIL GASKET SEAT FOAM GASKET GASKET SEAT DETAIL FOAM GASKET APPROXIMATELY 1 4 OVERLAP BASIN ...

Страница 6: ...stallation Only 4 1 Cut the tailpipe to the dimension determined in Figure 4 1 4 2 Install the sink drain components to the lid as shown in Figure 4 2 4 3 Orient the lid assembly as shown in Figure 4 3 and secure the trap components HAND TIGHTEN the assembly to the lid at this time Adjustment will be required in Step 5 Note To ensure a proper water seal the extension must be installed as shown in ...

Страница 7: ...LATION STEP 5 Final Assembly NOTE External plumbing configuration will vary depending on the location of basin location of main stack and available space 5 1 Place the pump in the basin as shown in Figure 5 1 NOTE If installing the internal trap rotate the tail pipe to the orientation shown in Figure 5 1 5 2 Install the lid components as shown in Figure 5 2 NOTE Pull excess cordage through the ope...

Страница 8: ...13 2 Basin Tank 1 013017 013017 3 Discharge 1 013732 N A 4 Basin Lid 1 013018 013018 A 5 Hardware pack seal 1 154256 154256 6 Unicheck 1 30 0181 30 0181 Notes 1 Hardware pack consist of 8 1 4 20 x 1 1 8 long round head stainless steel machine screws 8 1 4 20 stainless steel hex nuts and 16 1 4 flat stainless steel washers along with 1 pipe cap and 1 o ring and 1 pipe seal Copyright 2017 Zoeller Co...

Отзывы: