5.3 FAQ

Is it possible 

to improve the 

temperature rise?

To improve 

the efficiency 

of your heat 

pump it is 

recommended 

to:

•  Cover the pool using a cover (bubble cover, shutter, etc.) to avoid heat 

losses.

•  Take advantage of a period when outside temperatures are warm (on 

average > 10 °C at night), to guarantee easier temperature rises (this can 

take several days, its duration can vary depending on weather conditions 

and the heat pump sizing).

•  Keep the evaporator clean.

Check that the 

filtering time is 

sufficient

•  During the temperature rise phase, water circulation must be continuous 

(24*7).

•  To maintain the temperature throughout the season, switch to «automatic» 

circulation at least 12h/day (the longer this period, the more the heat pump 

will have a sufficient operating range to warm).

Setting the set point to the maximum will not heat the water quicker.

Why doesn’t my 

heat pump heat?

•  On start-up the appliance stays in «pause» for 30 seconds before starting: check that this 

time has elapsed.

•  When the set point temperature is reached, the heat pump stops heating: check that the 

water temperature is less than the set point (see §3.3) 

•  When the water flow is nil or insufficient, the heat pump stops: check that the water is 

flowing correctly through the heat pump and that the hydraulic fittings have been installed 

correctly. 

•  When the outside temperature drops below 7°C, the heat pump stops: check the outside 

temperature. 

•  The heat pump may have detected an operating fault: check for a code displayed on the 

screen, if there is one refer to §5.1. 

•  If these points have been checked and the problem persists: contact your reseller.

My appliance is 

draining water: Is 

this normal?

•  Your appliance drains water in the form of condensates. This water is the humidity from the 

air that condenses when in contact with some of the cold components of the heat pump. 

•  Warning: your appliance can drain several litres of water per day.

Where should my 

water treatment 

system be located 

relative to the 

heating system?

•  The water treatment system (chlorinator, salt water chlorinator, etc.) must be installed 

preferably downstream from the heat pump (see location §2.3) and be compatible with it 

(contact the manufacturer)

6. Registering the product

Register your product on our website: 

 

-

be the first to be informed of new Zodiac® products and special offers, 

 

-

help us to constantly improve our product quality.

For Australia/NZ/Oceania - www.zodiac.com.au

Содержание Z200

Страница 1: ...Instructions for installation ...

Страница 2: ...treatment Additional recommendations relative to pressurised appliances PED 97 23 EC Installation and maintenance It is prohibited to install the appliance close to combustible materials or close to the air intake on an adjacent building For some appliances it is imperative to use the protection grate accessory if the installation is located in an unregulated access area During installation repair...

Страница 3: ...of the location 4 2 2 Installing the appliance 4 2 3 Hydraulic connections 5 2 4 Electric connections 5 3 Use 6 3 1 Presentation of the regulation 6 3 2 Checks before commissioning 6 3 3 Starting up the appliance 6 3 4 Checks to carry out once the appliance is running 7 3 5 Wintering 7 4 Maintenance 7 4 1 Maintenance instructions 7 4 2 Recycling 7 5 Troubleshooting 8 5 1 Displays 8 5 2 Appliance m...

Страница 4: ...pump must be installed at a minimum distance of 3 5m from the edge of the pool in order to avoid any projections of spray onto the appliance This distance is determined by the electric standards applicable locally the heat pump must not be installed close to a heat source or to a source of inflammable gas close to a road with a risk of water or mud being sprayed facing strong winds with the blower...

Страница 5: ... designed for connection to mains electricity using a neutral TT and TNS wiring Electric protection using a circuit breaker D curve see 2 4 3 for ratings with a 30 mA ground fault circuit breaker at the head of the line circuit breaker or switch Acceptable voltage variation 10 7 while running 2 4 2 Connections Check the strength of the power supply cable on the connection terminal block Loose term...

Страница 6: ... but water flow too low or missing No fault On Off button Pool water temperature reading and parameter setting button Value adjustment buttons 3 2 Checks before commissioning Correct tightening of hydraulic fittings Good stability appliance level and vertical The electric power supply cable must be isolated from all sharp or hot elements that could damage or crush it 3 3 Starting up the appliance ...

Страница 7: ... If wintering the heat pump only do not screw the fittings back on instead fit 2 caps supplied to the condenser water intake and discharge Install a micro ventilated wintering cover on the heat pump 4 Maintenance 4 1 Maintenance instructions It is recommended to carry out general servicing of the appliance on wintering and recommissioning at least once per year in order to check it is in good work...

Страница 8: ... display The pool temperature is above the set point temperature There is a message on the screen Water flow absent or incorrect The air temperature is too low Check the power supply voltage and fuse F1 Increase the set point temperature Check the meaning of the message in 5 1 Check the water flow by pass filtering Wait until the air temperature returns to within the operating range The appliance ...

Страница 9: ... set point see 3 3 When the water flow is nil or insufficient the heat pump stops check that the water is flowing correctly through the heat pump and that the hydraulic fittings have been installed correctly When the outside temperature drops below 7 C the heat pump stops check the outside temperature The heat pump may have detected an operating fault check for a code displayed on the screen if th...

Страница 10: ...D Flow rate controller E1 High pressure switch E2 Low pressure switch F1 Fuse KM1 Compressor relay KM2 Fan relay KM3 Auxiliary pump relay KM4 Complementary relay M1 Compressor M2 Fan SD1 Water temperature sensor SD2 Air temperature sensor SD3 Defrost sensor T1 Transformer 1 2 3 4 Connector terminal for connecting heating priority ...

Страница 11: ...0 Weight Kg M3 45 M4 50 M5 53 Description 2 1 3 4 5 English 1 Pool water inlet 2 Pool water outlet 3 Evaporator 4 Location for drilling for priority heating cable run 5 Location for drilling for remote control cable run ...

Страница 12: ...ase contact your retailer ZODIAC is a registered trademark of Zodiac International S A S U used under license Your retailer Zodiac Group Australia Pty Ltd 219 Woodpark Road Smithfield NSW 2164 Phone 1300 763 021 www zodiac com au ...

Отзывы: