5.3 FAQ
Is it possible
to improve the
temperature rise?
To improve
the efficiency
of your heat
pump it is
recommended
to:
• Cover the pool using a cover (bubble cover, shutter, etc.) to avoid heat
losses.
• Take advantage of a period when outside temperatures are warm (on
average > 10 °C at night), to guarantee easier temperature rises (this can
take several days, its duration can vary depending on weather conditions
and the heat pump sizing).
• Keep the evaporator clean.
Check that the
filtering time is
sufficient
• During the temperature rise phase, water circulation must be continuous
(24*7).
• To maintain the temperature throughout the season, switch to «automatic»
circulation at least 12h/day (the longer this period, the more the heat pump
will have a sufficient operating range to warm).
Setting the set point to the maximum will not heat the water quicker.
Why doesn’t my
heat pump heat?
• On start-up the appliance stays in «pause» for 30 seconds before starting: check that this
time has elapsed.
• When the set point temperature is reached, the heat pump stops heating: check that the
water temperature is less than the set point (see §3.3)
• When the water flow is nil or insufficient, the heat pump stops: check that the water is
flowing correctly through the heat pump and that the hydraulic fittings have been installed
correctly.
• When the outside temperature drops below 7°C, the heat pump stops: check the outside
temperature.
• The heat pump may have detected an operating fault: check for a code displayed on the
screen, if there is one refer to §5.1.
• If these points have been checked and the problem persists: contact your reseller.
My appliance is
draining water: Is
this normal?
• Your appliance drains water in the form of condensates. This water is the humidity from the
air that condenses when in contact with some of the cold components of the heat pump.
• Warning: your appliance can drain several litres of water per day.
Where should my
water treatment
system be located
relative to the
heating system?
• The water treatment system (chlorinator, salt water chlorinator, etc.) must be installed
preferably downstream from the heat pump (see location §2.3) and be compatible with it
(contact the manufacturer)