manualshive.com logo in svg
background image

 

 

H03818-00.A3 EN – 2012-03

 

 

 

2.3 Electrical connection 

 

 

Place the control box at a distance of at least 

3.5 

meters

 

from the 

pool edge and away from direct sunlight; it can either be placed on 
the ground or attached to the caddy.

 

 

Connect  the  cleaner  cable  to  the  control  box 

(1)

 

and  lock  the 

connector  by  firmly  tightening  the  ring  by  turning  it  clockwise

 

(2).

 

Make sure the connector is sufficiently pushed into place, if this i

not the case repeat operation.

 

 

Connect the power cable. Only connect the control box to a power 
outlet protected by a 30 mA maximum ground fault circuit breaker 

(if in doubt contact a qualified electrician)

Ensure that the plug is 

permanently and easily accessible. 

 

 

 

 

2.4 Operation 

 

Program I:

 

Maximised cleaning of the pool floor in minimum time. 

Duration 1.30 hr.

 

Program II:

 

Intense cleaning of the pool floor and pool sides, including the waterline. 

Duration 2.30 hr.

 

OFF button:

 used to cut the 

cleaner power supply at the end of a cleaning cycle.

 

 

2.4.1. Start-

up

 

 

 

To start your cleaner, press the button for "Cycle I" cleaning program. "Cycle 
I" cleaning is the primary cleaning cycle for inground pools. If an alternative 
cycle  is  preferred,  press  "Cycle  II".    The  indicator  light  illuminates  and  the 
cleaner starts up after just a few seconds. When the cleaner is powered ON it 
will remain in standby until the Cycle I button is pressed

 

(1). 

 

When the "Cycle I" program button is selected the

 

indicator light above will 

illuminate. The cleaner

 

will start in a few seconds.

 

 

To  change  the  selected  cleaning  cycle,  press  the

 

new  cycle  button  and  the 

new cycle will start in a

 

few seconds.

 

 

If you wish to stop the cleaner during a cleaning cycle, press the OFF

 

button 

(2).

  

 

2.4.2

. End of program

 

 

 

At the end of the cycle, the cleaner will stop and after 15 minutes the light will flash slowly to indicate the cycle 
is completed.

 

 

Cleaner includes

 

a safety feature that automatically stops the cleaner after about 20

 

seconds, when it is 

powered on, but not submerged

 

in the water. For pools equipped with a beach area,

 

this safety feature allows 

the cleaner to reverse,

 

and back into the pool when the impeller is out of

 

the water.

 

 

Disconnect the control unit cable from t

he electrical outlet. 

 

Disconnect the cable from the control unit.

 

 

At the end of each cycle, coil the cable starting at the cleaner and go toward the connection point at control 
unit. Remove coils or twists along the way. 

 

The cleaner control unit is water-resistant, not waterproof. In order to prevent electrocution, which 
could result in serious injury or death, never submerge the control unit. 

 

If you use an extension cable to connect your cleaner to the power supply, ensure the control box is 
placed no less than 3.5 meters from the pool edge. 

 

 

 

 

 

EN 

Содержание V3

Страница 1: ...EN...

Страница 2: ...er to the installation instructions relating to the swimming pool equipment for which the cleaner will be an integral part The cleaner is to be supplied through a Residual Current Device RCD with a ra...

Страница 3: ...before removing it from water and do not operate out of water Do not remove the cleaner from the pool for 15 minutes after the cleaning cycle has completed Clean filter canister in the cleaner after e...

Страница 4: ...n the cart as shown 1 Make sure the upper tubes handles are in the proper orientation and align the screw holes Position the bottom power cable hook as shown 2 Place the cable hook plate opposite the...

Страница 5: ...s to the caddy using four screws V3 figure 9 V3 4WD figure 10 The transport caddy is now ready to use 1 4 Connecting the control unit to the caddy Position the control unit over the control unit hook...

Страница 6: ...re starting a cleaning cycle Do not leave the cleaner in the water permanently Stow your cleaner on its caddy as soon as possible after use in order to avoid distorting the flexible edge at the openin...

Страница 7: ...When the cleaner is powered ON it will remain in standby until the Cycle I button is pressed 1 When the Cycle I program button is selected the indicator light above will illuminate The cleaner will s...

Страница 8: ...t the cover 2 until it is secured in the vertical position Figure 1 Remove the filter assembly from the body 3 Figure 2 Push the quick release button on the canister assembly 4 and pull open the filte...

Страница 9: ...es as soon as one of the wear indicators has been reached even if the blade wear is not even It recommended to replace the brushes every two 2 years Lift the cleaner to a vertical position so that the...

Страница 10: ...s appear just after start pressing the Power or Cycle button to start the cleaner 20 seconds Floating cable is not properly plugged into the control unit Unplug the floating cable from the control uni...

Страница 11: ...trike Symptom Cause Solution The cleaner does not stay firmly on the pool bottom There is air in the appliance casing Submerge the cleaner following the procedure in Section 2 2 Submerging the Cleaner...

Страница 12: ...and obtain a warranty ID number for the warranty claim Contact details are Zodiac Group Australia Pty Ltd Customer Service 219 Woodpark Road Telephone 1800 688 552 Smithfield NSW 2164 Email address a...

Страница 13: ...Notes...

Страница 14: ...Notes...

Страница 15: ...Notes...

Страница 16: ......

Отзывы: