To keep your TRi-XO Unit in the best possible condition it is recommended regular
maintenance should be performed.
INSPECTING AND CLEANING THE ELECTRODE
•
In areas that experience calcium hardness the TRi-XO electrode will benefit
from cleaning.
To clean your electrode:
1. Switch off the filter pump and chlorine
generator, close necessary valves and
unplug the cell terminal cap.
2. Unscrew the retaining ring and remove the
electrode. If calcium buildup is present,
immerse the electrode in cell cleaning
solution without immersing the terminals.
3.
We recommend using Zodiac Salt
Chlorinator Cell Cleaner to clean the
electrode. However you can mix your own
by carefully adding one (1) part of Hydrochloric (Muriatic) acid to ten (10) parts
water. Stronger solutions will shorten terminal life.
4. Allow the cleaning solution to dissolve the calcium deposits for about 10 minutes.
Dispose of the cleaning solution at an approved Council Depot and never into
storm water or sewage drains.
6. Rinse the electrode in clean water and re-fit
the electrode in the cell housing.
7. Replace the cell head and plug assembly
and reset valves and switches. Turn pump
and TRi-XO on.
8. Confirm chlorine output and settings on
the power pack. Timer settings will be
automatically retained.