15
Electric heater
Electric heater heating
/
Electric heater off
Circulator (hot water coil
option)
Circulator on
/
Circulator idle
Alarm
Alarm in progress
/
/
Celsius
Appliance configured
to measure in degrees
Celsius
/
/
“Manual” mode
Programming using
“manual” mode.
/
/
Humidity level percentage
Appliance configured as
a humidity sensor
/
/
3.2 I Operation
3.2.1 Switching on the appliance
•
Power on the appliance (by switching on the general terminal board),
•
The program version remains visible for 5 seconds then "OFF" and "KEY" is displayed before the appliance starts.
Only on Sirocco 5T models (three phased):
•
This operation must be only be carried out by a qualified professional.
•
The phase order controller protects the compressor. It is forbidden to invert phases:
-
On the power contactor.
-
On the compressor.
•
When the dehumidifier is switched on, check the status of the phase order controller as shown below:
Indicator light
status
OK~
OK~
•
If there is a phase inversion or missing phase:
1.
Disconnect the appliance from the power supply;
2. Invert two phases directly on the appliance connection terminal board;
3. Restore power to the appliance and check the status of the indicator lights.