background image

 

H03609

00.B1.EN

 

 

2012/01

 

 

2

 

C

R

 

power

 

supply

 

230V

1N

50Hz

 

N

R

S

T

 

power

 

supply

 

400V

3N

50Hz

 

TH

 

control

 

thermostat

 

with

 

digital

 

display

 

F1

 

fuse

 

3.15

 

A

G

 

CD

 

flow

 

controller

 

So

 

pool

 

water

 

control

 

sensor

 

(PTC)

 

R

 

Heating

 

element

 

(power

 

engraved

 

on

 

the

 

metal

 

resistor

 

cup)

 

KM1

 

power

 

contactor

 

TS

 

safety

 

thermostat

 

positive

 

(triggering

 

at

 

63°C,

 

manual

 

reset)

 

GN

GG

 

black

 

or

 

grey

 

sheath

 

CN

 

Black

 

cable

 

with

 

clips

 

of

 

colours

 

V

j

 

green

yellow

 

B

 

blue

 

M

 

brown

 

Bl

 

white

 

N

 

black

 

Ro

 

red

 

Vi

 

violet

 

 

Ground

 

 

Description

  

 

 

 

1

 

Controller

 

2

 

flow

 

switch

 

3

 

cable

 

crossing

 

4

 

Preheater

 

body

  

5

 

½

 

union

 

Ø63/50

 

fittings

 

6

 

safety

 

thermostat

 

positive

 

7

 

power

 

contactor

 

8

 

connection

 

terminal

 

9

 

Heating

 

element

 

10

 

Pockets

 

+

 

control

 

sensors

 

11

 

Pockets

 

+

 

high

 

limit

 

sensors

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание RED LINE

Страница 1: ...EN Instructions for installation and use English H03609 00 B 2012 01 ...

Страница 2: ...ay occur as a result of failure to comply with local standards pertaining to installation This appliance must be handled by competent and qualified personnel physically and mentally who are familiar with the operating instructions by reading the user guide Persons who do not satisfy these requirements must not handle the device so as to avoid exposure to potentially dangerous parts If the device m...

Страница 3: ...t temperature 6 6 Product registration 6 7 Conformity certificate 6 Available in appendix at the end of the manual wiring diagrams dimensions and description 1 Information before installation 1 1 General terms of delivery storage and transport Any equipment even carriage and packing free travels at the consignee s risk The consignee shall make reservations in writing on the carrier s bill of ladin...

Страница 4: ...m h it is recommended to use a by pass as this makes maintenance of the appliance simpler on the swimming pool filtration circuit after the filter and before any water treatment unit Check the tightening of the hydraulic connections and for leaks Red Line Hydraulic circuit pressure Connections Minimum water flowrate Maximum water flowrate test service 3 6 9 12 4 bars 2 bars Ø63 or Ø50 5 m h 30 m h...

Страница 5: ...3 1 Presentation of the regulation 3 2 Starting the device Fully open valves 2 and 3 and close valve 1 see 2 2 if installed Start the filtration pump Check that there is no air in the circuit Check that the water flow rate is between 5 and 30m h If it is above 30m h adjust valve 1 so as to obtain 30m h maximum Turn on control unit power then start it Adjust the setpoint temperature display and mod...

Страница 6: ...ician Check the electrical components Check the ground connection Check that the electric cable connections are properly tightened and that the electric box is clean 4 2 Recycling This symbol means that your device must not be thrown in the bin The device must be collected by a selective system in view of re use recycling or similar Any substances it may contain which are potentially dangerous to ...

Страница 7: ...lator the on indicator light goes off the pool water temperature is displayed Simultaneously press and hold and for 5 seconds PA is displayed Press Then enter the value 80 using the or keys access code to the settings menu Press to confirm this code PA is displayed Simultaneously press and hold the and keys for 5 seconds Press to scroll through each parameter until r2 is displayed Press the curren...

Страница 8: ...H03609 00 B1 EN 2012 01 1 Wiring diagram Red Line 3 6 9 kW single phase and three phase Red Line 12 kW three phase ...

Страница 9: ...p KM1 power contactor TS safety thermostat positive triggering at 63 C manual reset GN GG black or grey sheath CN Black cable with clips of colours V j green yellow B blue M brown Bl white N black Ro red Vi violet Ground Description 1 Controller 2 flow switch 3 cable crossing 4 Preheater body 5 union Ø63 50 fittings 6 safety thermostat positive 7 power contactor 8 connection terminal 9 Heating ele...

Страница 10: ...H03609 00 B1 EN 2012 01 3 Dimensions Red Line A B weight mm mm Kg 3 6 538 452 3 5 9 12 638 552 4 ...

Страница 11: ...Notes ...

Страница 12: ...ct your retailer ZODIAC is a registered trademark of Zodiac International S A S U used under license Votre revendeur your retailer Zodiac pool Care Europe BP 90023 49180 St Barthélémy d Anjou cedex France S A S U au capital de 517 200 SIREN 395 068 679 RCS PARIS Plaque signalétique Product name plate ...