manualshive.com logo in svg
background image

H03609

00.B1.EN

 

 

2012/01

 

 

6

 

5.2

 

Fuse

 

replacement

 

 

 

IMPORTANT!

 

Disconnect

 

power

 

to

 

the

 

appliance!

 

 

Remove

 

the

 

cover.

  

 

Disconnect

 

the

 

regulator.

  

 

Remove

 

the

 

regulator

 

cover.

  

 

Remove

 

the

 

fuse

 

(T3,

 

15AH250V).

 

 

5.3

 

FAQ

 

 

Where

 

should

 

my

 

water

 

treatment

 

system

 

be

 

positioned

 

with

 

respect

 

to

 

the

 

heating

 

system?

 

The

 

water

 

treatment

 

system

 

(chlorinator,

 

salt

 

chlorinator,

 

etc.)

 

must

 

be

 

installed

 

preferably

 

downstream

 

from

 

the

 

appliance

 

(see

 

installation

 

§2.2),

 

and

 

must

 

be

 

compatible

 

with

 

the

 

latter

 

(check

 

with

 

the

 

manufacturer)

 

Is

 

it

 

possible

 

to

 

improve

 

temperature

 

performance?

 

protect

 

the

 

pool

 

with

 

a

 

cover

 

(floating

 

cover,

 

roller

 

cover,

 

etc.),

 

to

 

avoid

 

heat

 

loss

 

Check

 

that

 

filtration

 

time

 

is

 

sufficient

  

during

 

the

 

heating

 

phase,

 

water

 

flow

 

must

 

be

 

continuous

 

(24/24)

 

to

 

maintain

 

the

 

temperature

 

throughout

 

the

 

season,

 

allow

 

for

 

“automatic”

 

flow

 

of

 

at

 

least

 

12

 

hours/day

 

(the

 

longer

 

automatic

 

flow

 

is

 

used,

 

the

 

more

 

time

 

the

 

appliance

 

will

 

have

 

to

 

function

 

and

 

to

 

heat

 

the

 

water)

 

 

5.4

 

Modification

 

of

 

the

 

maximum

 

setpoint

 

temperature

 

 

Turn

 

off

 

the

 

regulator

 

(the

 

“on”

 

indicator

 

light

 

goes

 

off,

 

the

 

pool

 

water

 

temperature

 

is

 

displayed).

 

 

Simultaneously

 

press

 

and

 

hold

 

 

and

 

 

for

 

5

 

seconds,

 

“PA”

 

is

 

displayed.

 

 

Press

 

.

 

 

Then

 

enter

 

the

 

value

 

80”

 

using

 

the

 

 

or

 

 

keys

 

(access

 

code

 

to

 

the

 

settings

 

menu).

 

 

Press

 

 

to

 

confirm

 

this

 

code,

 

“PA”

 

is

 

displayed.

 

 

Simultaneously

 

press

 

and

 

hold

 

the

 

 

and

 

 

keys

 

for

 

5

 

seconds.

 

 

Press

 

 

to

 

scroll

 

through

 

each

 

parameter

 

until

 

“r2”

 

is

 

displayed.

 

 

Press

 

,

 

the

 

current

 

value

 

of

 

the

 

parameter

 

“r2”

 

is

 

displayed.

  

 

Press

 

 

or

 

 

to

 

modify

 

the

 

maximum

 

setpoint

 

value.

  

 

Press

   

to

 

confirm

 

this

 

new

 

value.

 

 

Simultaneously

 

press

 

and

 

hold

 

 

and

 

 

for

 

5

 

seconds

 

to

 

return

 

to

 

the

 

pool

 

water

 

temperature

 

display.

 

 

6.

 

Product

 

registration

 

 

Register

 

your

 

product

 

using

 

our

 

website:

  

you

 

will

 

be

 

among

 

the

 

first

 

to

 

be

 

informed

 

of

 

new

 

Zodiac

 

products

 

and

 

special

 

offers,

 

You

 

can

 

help

 

us

 

to

 

constantly

 

improve

 

our

 

product

 

quality.

 

 

Australia

 

 

New

 

Zealand

 

www.zodiac.com.au

 

South

 

Africa

 

www.zodiac.co.za

 

Europe

 

and

 

rest

 

of

 

the

 

world

 

www.zodiac

poolcare.com

 

 

7.

 

Conformity

 

certificate

 

 

Z.P.C.E.

 

declares

 

that

 

the

 

following

 

products

 

or

 

ranges:

 

 

Special

 

swimming

 

pool

 

heater:

 

Red

 

Line

 

+

 

3

6

9

12

 

 

are

 

in

 

compliance

 

with

 

the

 

provisions

 

of:

 

 

the

 

ELECTROMAGNETIC

 

COMPATIBILITY

 

directive

 

89/336/EEC

 

 

the

 

LOW

 

VOLTAGE

 

directive

 

73/23/EEC

 

Содержание RED LINE

Страница 1: ...EN Instructions for installation and use English H03609 00 B 2012 01 ...

Страница 2: ...ay occur as a result of failure to comply with local standards pertaining to installation This appliance must be handled by competent and qualified personnel physically and mentally who are familiar with the operating instructions by reading the user guide Persons who do not satisfy these requirements must not handle the device so as to avoid exposure to potentially dangerous parts If the device m...

Страница 3: ...t temperature 6 6 Product registration 6 7 Conformity certificate 6 Available in appendix at the end of the manual wiring diagrams dimensions and description 1 Information before installation 1 1 General terms of delivery storage and transport Any equipment even carriage and packing free travels at the consignee s risk The consignee shall make reservations in writing on the carrier s bill of ladin...

Страница 4: ...m h it is recommended to use a by pass as this makes maintenance of the appliance simpler on the swimming pool filtration circuit after the filter and before any water treatment unit Check the tightening of the hydraulic connections and for leaks Red Line Hydraulic circuit pressure Connections Minimum water flowrate Maximum water flowrate test service 3 6 9 12 4 bars 2 bars Ø63 or Ø50 5 m h 30 m h...

Страница 5: ...3 1 Presentation of the regulation 3 2 Starting the device Fully open valves 2 and 3 and close valve 1 see 2 2 if installed Start the filtration pump Check that there is no air in the circuit Check that the water flow rate is between 5 and 30m h If it is above 30m h adjust valve 1 so as to obtain 30m h maximum Turn on control unit power then start it Adjust the setpoint temperature display and mod...

Страница 6: ...ician Check the electrical components Check the ground connection Check that the electric cable connections are properly tightened and that the electric box is clean 4 2 Recycling This symbol means that your device must not be thrown in the bin The device must be collected by a selective system in view of re use recycling or similar Any substances it may contain which are potentially dangerous to ...

Страница 7: ...lator the on indicator light goes off the pool water temperature is displayed Simultaneously press and hold and for 5 seconds PA is displayed Press Then enter the value 80 using the or keys access code to the settings menu Press to confirm this code PA is displayed Simultaneously press and hold the and keys for 5 seconds Press to scroll through each parameter until r2 is displayed Press the curren...

Страница 8: ...H03609 00 B1 EN 2012 01 1 Wiring diagram Red Line 3 6 9 kW single phase and three phase Red Line 12 kW three phase ...

Страница 9: ...p KM1 power contactor TS safety thermostat positive triggering at 63 C manual reset GN GG black or grey sheath CN Black cable with clips of colours V j green yellow B blue M brown Bl white N black Ro red Vi violet Ground Description 1 Controller 2 flow switch 3 cable crossing 4 Preheater body 5 union Ø63 50 fittings 6 safety thermostat positive 7 power contactor 8 connection terminal 9 Heating ele...

Страница 10: ...H03609 00 B1 EN 2012 01 3 Dimensions Red Line A B weight mm mm Kg 3 6 538 452 3 5 9 12 638 552 4 ...

Страница 11: ...Notes ...

Страница 12: ...ct your retailer ZODIAC is a registered trademark of Zodiac International S A S U used under license Votre revendeur your retailer Zodiac pool Care Europe BP 90023 49180 St Barthélémy d Anjou cedex France S A S U au capital de 517 200 SIREN 395 068 679 RCS PARIS Plaque signalétique Product name plate ...