manualshive.com logo in svg
background image

H03609

00.B1.EN

 

 

2012/01

 

 

5

 

 

 

 

If

 

the

 

water

 

flow

 

rate

 

is

 

too

 

low

 

(less

 

than

 

5

 

m³/h),

 

or

 

if

 

the

 

filtration

 

is

 

stopped,

 

the

 

“reg”

 

indicator

 

light

 

will

 

flash

 

and

 

the

 

heater

 

will

 

stop

 

heating,

  

 

When

 

the

 

pool

 

has

 

reached

 

the

 

desired

 

temperature,

 

the

 

“reg”

 

indicator

 

light

 

goes

 

out,

 

the

 

heater

 

will

 

stop

 

heating.

 

 
 

3.3

 

Checks

 

to

 

be

 

carried

 

out

 

after

 

operating

 

for

 

a

 

few

 

moments

 

 

Check

 

that

 

the

 

heater

 

stops

 

heating

 

when:

  

 

the

 

setpoint

 

temperature

 

is

 

decreased

 

or

 

when

 

the

 

control

 

is

 

shut

 

off,

  

 

filtration

 

is

 

switched

 

off.

 

 

3.4

 

Winter

 

storage

 

 

 

Winter

 

storage

 

is

 

essential

 

due

 

to

 

the

 

risk

 

of

 

body

 

of

 

the

 

heater

 

freezing

 

and

 

breaking.

 

This

 

situation

 

is

 

not

 

covered

 

by

 

the

 

warranty.

 

 

 

Turn

 

off

 

control

 

unit

 

power,

  

 

Shut

 

off

 

water

 

circulation,

  

 

Drain

 

the

 

heater

 

:

  

close

 

valves

 

2

 

and

 

3

 

(see

 

§2.2),

 

if

 

installed,

  

unscrew

 

the

 

fittings

 

to

 

drain

 

the

 

heater,

 

when

 

the

 

heater

 

is

 

empty,

 

lightly

 

retighten

 

the

 

fittings,

 

without

 

creating

 

a

 

seal.

  

 

4.

 

Maintenance

 

 

4.1

 

Maintenance

 

instructions

 

 

 

It

 

is

 

recommended

 

that

 

the

 

device

 

be

 

general

 

serviced

 

on

 

a

 

yearly

 

basis

 

to

 

ensure

 

proper

 

operation,

 

maintain

 

performance

 

levels

 

and

 

prevent

 

some

 

potential

 

failures.

 

This

 

is

 

the

 

responsibility

 

of

 

the

 

user

 

and

 

must

 

be

 

performed

 

by

 

a

 

qualified

 

technician.

 

 

 

Check

 

the

 

electrical

 

components,

 

 

Check

 

the

 

ground

 

connection,

 

 

Check

 

that

 

the

 

electric

 

cable

 

connections

 

are

 

properly

 

tightened

 

and

 

that

 

the

 

electric

 

box

 

is

 

clean

  

 

4.2

 

Recycling

 

 

This

 

symbol

 

means

 

that

 

your

 

device

 

must

 

not

 

be

 

thrown

 

in

 

the

 

bin.

 

The

 

device

 

must

 

be

 

collected

 

by

 

a

 

selective

 

system

 

in

 

view

 

of

 

re

use,

 

recycling

 

or

 

similar.

 

Any

 

substances

 

it

 

may

 

contain

 

which

 

are

 

potentially

 

dangerous

 

to

 

the

 

environment

 

shall

 

be

 

eliminated

 

or

 

neutralised.

 

Request

 

information

 

on

 

recycling

 

procedures

 

from

 

your

 

retailer.

 

 

5.

 

Resolution

 

of

 

problem

 

 

5.1

 

Malfunctions

 

of

 

the

 

device

 

 

Dysfunction

 

Causes

 

solution

 

The

 

display

 

does

 

not

 

work

 

Power

 

is

 

not

 

supplied

 

to

 

the

 

appliance

 

The

 

regulator

 

fuse

 

is

 

blown

 

(for

 

replacement,

 

see

 

§5.2)

 

The

 

appliance

 

displays

 

a

 

flashing

 

“E0”

 

The

 

control

 

sensor

 

is

 

out

 

of

 

service

 

or

 

disconnected

 

Appliance

 

power

 

off

 

and

 

locked

 

out,

 

reconnect

 

or

 

standard

 

replacement

 

of

 

the

 

sensor

 

(the

 

“E0”

 

fault

 

is

 

automatically

 

cleared)

 

The

 

pool

 

water

 

is

 

hotter

 

than

 

requested

 

The

 

regulator

 

is

 

not

 

operating

 

correctly

 

check

 

that

 

the

 

power

 

contactor

 

is

 

not

 

damaged

 

The

 

“reg”

 

light

 

is

 

on

 

but

 

the

 

appliance

 

does

 

not

 

heat

 

the

 

positive

 

safety

 

overheating

 

thermostat

 

(TS)

 

has

 

been

 

tripped

 

reset

 

it

 

by

 

removing

 

the

 

small

 

cap

 

to

 

the

 

side

 

of

 

the

 

appliance

 

and

 

by

 

pressing

 

on

 

its

 

central

 

cap

 

the

 

appliance

 

has

 

not

 

been

 

installed

 

in

 

compliance

 

with

 

instructions

 

contact

 

an

 

approved

 

technician

 

 
 
 
 
 
 
 
 
 

Содержание RED LINE

Страница 1: ...EN Instructions for installation and use English H03609 00 B 2012 01 ...

Страница 2: ...ay occur as a result of failure to comply with local standards pertaining to installation This appliance must be handled by competent and qualified personnel physically and mentally who are familiar with the operating instructions by reading the user guide Persons who do not satisfy these requirements must not handle the device so as to avoid exposure to potentially dangerous parts If the device m...

Страница 3: ...t temperature 6 6 Product registration 6 7 Conformity certificate 6 Available in appendix at the end of the manual wiring diagrams dimensions and description 1 Information before installation 1 1 General terms of delivery storage and transport Any equipment even carriage and packing free travels at the consignee s risk The consignee shall make reservations in writing on the carrier s bill of ladin...

Страница 4: ...m h it is recommended to use a by pass as this makes maintenance of the appliance simpler on the swimming pool filtration circuit after the filter and before any water treatment unit Check the tightening of the hydraulic connections and for leaks Red Line Hydraulic circuit pressure Connections Minimum water flowrate Maximum water flowrate test service 3 6 9 12 4 bars 2 bars Ø63 or Ø50 5 m h 30 m h...

Страница 5: ...3 1 Presentation of the regulation 3 2 Starting the device Fully open valves 2 and 3 and close valve 1 see 2 2 if installed Start the filtration pump Check that there is no air in the circuit Check that the water flow rate is between 5 and 30m h If it is above 30m h adjust valve 1 so as to obtain 30m h maximum Turn on control unit power then start it Adjust the setpoint temperature display and mod...

Страница 6: ...ician Check the electrical components Check the ground connection Check that the electric cable connections are properly tightened and that the electric box is clean 4 2 Recycling This symbol means that your device must not be thrown in the bin The device must be collected by a selective system in view of re use recycling or similar Any substances it may contain which are potentially dangerous to ...

Страница 7: ...lator the on indicator light goes off the pool water temperature is displayed Simultaneously press and hold and for 5 seconds PA is displayed Press Then enter the value 80 using the or keys access code to the settings menu Press to confirm this code PA is displayed Simultaneously press and hold the and keys for 5 seconds Press to scroll through each parameter until r2 is displayed Press the curren...

Страница 8: ...H03609 00 B1 EN 2012 01 1 Wiring diagram Red Line 3 6 9 kW single phase and three phase Red Line 12 kW three phase ...

Страница 9: ...p KM1 power contactor TS safety thermostat positive triggering at 63 C manual reset GN GG black or grey sheath CN Black cable with clips of colours V j green yellow B blue M brown Bl white N black Ro red Vi violet Ground Description 1 Controller 2 flow switch 3 cable crossing 4 Preheater body 5 union Ø63 50 fittings 6 safety thermostat positive 7 power contactor 8 connection terminal 9 Heating ele...

Страница 10: ...H03609 00 B1 EN 2012 01 3 Dimensions Red Line A B weight mm mm Kg 3 6 538 452 3 5 9 12 638 552 4 ...

Страница 11: ...Notes ...

Страница 12: ...ct your retailer ZODIAC is a registered trademark of Zodiac International S A S U used under license Votre revendeur your retailer Zodiac pool Care Europe BP 90023 49180 St Barthélémy d Anjou cedex France S A S U au capital de 517 200 SIREN 395 068 679 RCS PARIS Plaque signalétique Product name plate ...

Отзывы: