- 3 -
DESCRIPTION
Heat pump dimensions
Technical characteristics
* With an ambient air temperature of + 15°C and a pool water temperature of 24°C
• Unit protection class:
IP 24
• Type of refrigerant:
R410A
(see product name plate for refrigerant charge)
Do not vent R410A into atmosphere: R410A is a fluorinated greenhouse gas, covered by Kyoto Protocol, with a
Global Warming Potential (GWP) = 1975 - (Directive of the EC 842/2006)
• Ambient operating temperature (TS): Min.
5°C
/ Max.
38°C
Heat pump
Input*
Output*
Nominal
current
consumption*
Max. current
consumption
Sound
power
Sound
pressure at
10 m
Net weight
PowerPAC 1M
1.42
kW
6.6
kW
6.28
A
9
A
66.4
dBA
38.4
dBA
45
kg
PowerPAC 2M
1.64
kW
7.8
kW
7.34
A
10
A
67.4
dBA
39.4
dBA
46
kg
PowerPAC 3M
2.2
kW
11
kW
10.5
A
14.5
A
68
dBA
40
dBA
60
kg
Controller
:
On/Off or Stand-by
(press and hold 3 s)
.
:
Display required water temperature
.
+
: Increase required water temperature.
+
: Decrease required water temperature.
Controller ON indicator
Priority Heating output enabled indicator
Compressor ON (steady) or timed (blinking) indicator
Defrost in progress (steady) or timed (blinking) indicator
Indicators not active
n
o
p
q
r
t
s
u
v
nn
no
nm
np
n
Front panel.
o
Fan grid.
p
Controller.
q
Side panel (access to technical zone).
r
‘Flat fin’ evaporator.
s
Pool water inlet.
t
Pool water outlet
u
Cable gland.
v
Top panel.
nm
Structural post.
nn
Base.
no
Grooved end piece of evacuation of condensation.
np
Product name plate.