background image

                                                                                        

- 2 -

INTRODUCTION 

 

General delivery terms 

 

All equipment, even POST and PACKAGING PAID, is shipped at the sole risk of the receiver. The latter must record all reserves 
in writing on the shipping note of the HAULER in the case of visible or possible transport damage (Confirmation must be sent to 
the HAULER by registered mail within 48 hours). 
 
 
 
 
 

Remark:

 

if this is not the case, place the unit upright on the pallet and check its general state (if there is a doubt concerning 

correct machine operation, note the appropriate reserves on the hauler’s shipping note).

 

 

 
 
 
 
 
 

Packaging and content 
 
 
 
 

 
 

 

 
 
 
 
 

 

 
 
 
 
 

 
 
 
 
 
 

An accessories sachet is placed inside the unit (to recover this sachet, refer to the chapter «CONNECTIONS» paragraph «Access 
to technical compartment»).

 

 
 

 
 
                                                                                                                                                                                                      

 

 
 

Product name plate 

 

Before using or working on the unit, always check that the voltage indicated on the name plate corresponds to the power supply 
available (refer to the chapter «DESCRIPTION» for location of the name plate). 

 

 

Water treatment 

 

For our appliances to function under the best possible conditions, the following parameters must be respected: free chlorine: max. 
2.5 mg/l, total bromine : max. 5.5 mg/l, pH between 6.9 and 8.0. When using a chemical or electrical disinfecting system, the 
installer and user must check with the manufacturer that this system is compatible with our equipment. These systems must 
always be installed after the heating system. 

1030 

520

 

830

 

Transport upright in 
the original packaging. 

Weight of heat pump

 

PowerPAC 1M

 with packaging : 

 

55

 kg 

Weight of heat pump

 

PowerPAC 2M

 with packaging : 

 

56

 

kg 

Weight of heat pump

 

PowerPAC 3M

 with packaging : 

 

75

 

kg 

Contents of sachet :

  

2 sealing rings   + 2 half-union connectors Ø50 to be glued 

 + 5 anti-vibration pads   + 1 cable gland Ø21

The unit must always be stored and transported upright on a pallet and in the original packaging.

  

   

If the unit is stored or transported laying down, wait at least 12 hours before switching on. 

 

 

Technical 

instructions 

 

Warranty 

card 

 

Содержание POWER PAC 1M

Страница 1: ...Heat pump Instructions for installation and use F GB D NL E P I Ed 09 2008 R f 1011505 01 374274003 00 1M 2M 3M POWER PAC...

Страница 2: ...efore beginning any installation handling or repair work on the heat pump always isolate the electrical power supply to the unit In the case of a fault and or operating error on the heat pump the elec...

Страница 3: ...uired for installation 4 Selection of installation site 4 CONNECTIONS 5 Access to technical compartment 5 Hydraulics 5 Electrical 5 COMMISSIONING 7 Preliminary inspections 7 Commissioning step by step...

Страница 4: ...y available refer to the chapter DESCRIPTION for location of the name plate Water treatment For our appliances to function under the best possible conditions the following parameters must be respected...

Страница 5: ...6 kW 6 28 A 9 A 66 4 dBA 38 4 dBA 45 kg PowerPAC 2M 1 64 kW 7 8 kW 7 34 A 10 A 67 4 dBA 39 4 dBA 46 kg PowerPAC 3M 2 2 kW 11 kW 10 5 A 14 5 A 68 dBA 40 dBA 60 kg Controller On Off or Stand by press a...

Страница 6: ...t pump must be installed at a minimum distance from the pool This distance is defined by the locally valid electrical regulations In France the standard NF C 15 100 section 702 specifies that the unit...

Страница 7: ...ter flow rate 2 8 3 5 5 m3 h head loss 0 12 to 0 15 bar Electrical The electrical power supply to the heat pump must be protected with a fuse and isolator switch not provided in compliance with standa...

Страница 8: ...nd monitoring of the pool heating requirements even when the filter system has been switched off by the timer Connection of the Priority Heating function Use terminals 16 and 17 to control filter pump...

Страница 9: ...Note in the aforementioned configuration the heat pump is not yet supplied with pool water 2 Switch on the filter system 3 Progressively close valve V1 in order to increase the filter pressure to 150...

Страница 10: ...en 5 and 5 C the fan is switched off The compressor and fan restart after a time period of 2 to 5 minutes varies according to the compressor stoppage time If the ambient temperature drops below 5 C th...

Страница 11: ...matic if less than 4 dbP or dHP faults in one hour or press the key if the message dSr is blinking Alternating with the pool water temperature Water flow rate sensor fault ST4 Sensor defective or disc...

Страница 12: ...a high pressure spray Ensure no foreign bodies obstruct the fan grid Annual by a qualified and authorised technician Carry out the regular maintenance tasks refer to paragraph above Check the target...

Страница 13: ...G DIAGRAM With an aim to continuous improvement the products may be modified without prior notice Edition of 09 08 A IMPORTANT Elimination or shunting of a safety or remote control device automaticall...

Страница 14: ...e eliminated or neutralised Your appliance is reaching the end of its working life You would like to get rid of it or replace it Please do not throw it into the dustbin or into your local council s se...

Страница 15: ...N o t e s N o t e n A a n t e k e n i n g N o t a s N o t a...

Страница 16: ...N o t e s N o t e n A a n t e k e n i n g N o t a s N o t a...

Страница 17: ...t be carried out with total respect of valid safety regulations and acceptable professional practice recuperation of refrigerant nitrogen brazing etc All brazing work must be carried out by a qualifie...

Страница 18: ...yst mes de chauffage et de d shumidification de piscines En s appuyant sur le savoir faire technologique et l exp rience de PSA Zodiac vous apporte la garantie d appareils de tr s haut niveau tant dan...

Страница 19: ...hank you for trusting us and enjoy your bath at 28 C Please take a little time to fill in this guarantee form with your pool adviser Your details may be treated according to the law Informatique et ci...

Страница 20: ...n de s rie Type and serial number Utilisateur Owner Installateur installer Station service agr e PSA Technical support Garantie guaranty Date de livraison Delivery date Date de mise en route Date of...

Отзывы: