background image

IMPORTANT

 

 

These installation instructions are an integral part of the product and must be given to the 

installer and kept by the user. 
 

The warnings and indications contained in the present handbook must be carefully read and 
understood as they provide important information relative to handling and operating safety. 

This handbook must therefore always be kept available for later consultation. 
 

Installation must be carried out in compliance with valid regulations and the manufacturer’s 
instructions by a qualified professional. 

 
The term «qualified professional» refers to a person possessing the technical knowledge 

associated with P.S.A. components and heating installations. 
 

An installation error could result in physical injury to persons or animals as well as mechanical 
damage for which the manufacturer may under no circumstances be held responsible. 

 
After having unpacked the heat pump, the content should be checked for possible damage. 

 
Before connecting the heat pump, ensure that the data provided by P.S.A. is compatible with 

the true installation conditions and does not exceed the maximum authorised limits for the 
product in question. 

 
Before beginning any installation, handling or repair work on the heat pump, always isolate 

the electrical power supply to the unit. 
 

In the case of a fault and/or operating error on the heat pump, the electrical power supply 
must be isolated and no attempt should be made to repair the fault. 

 
Repair work may only be carried out by an authorised technical assistance service using 

original spare parts only. Non-respect of the aforementioned clauses may have a negative 
influence on the operating safety of the heat pump. 

 
To guarantee the efficiency and correct operation of the heat pump, it is important to ensure 

it is regularly maintained in compliance with the instructions provided by P.S.A. 
 

In the case where a heat pump is sold or transferred to another user, always ensure that all 
technical documentation is sent with the equipment to be used by the new user or installer. 

 
This heat pump may only be used for the purpose for which it was designed: to heat a 

swimming pool; all other uses must be considered inappropriate, incorrect or even 
dangerous. 

 
All contractual or extra-contractual responsibilities of P.S.A. will be considered nil and void for 

any damage caused by installation or operating errors, or due to non-respect of the 
instructions provided by P.S.A. or valid installation standards for the equipment object of the 

present document. 

Содержание POWER PAC 1M

Страница 1: ...Heat pump Instructions for installation and use F GB D NL E P I Ed 09 2008 R f 1011505 01 374274003 00 1M 2M 3M POWER PAC...

Страница 2: ...efore beginning any installation handling or repair work on the heat pump always isolate the electrical power supply to the unit In the case of a fault and or operating error on the heat pump the elec...

Страница 3: ...uired for installation 4 Selection of installation site 4 CONNECTIONS 5 Access to technical compartment 5 Hydraulics 5 Electrical 5 COMMISSIONING 7 Preliminary inspections 7 Commissioning step by step...

Страница 4: ...y available refer to the chapter DESCRIPTION for location of the name plate Water treatment For our appliances to function under the best possible conditions the following parameters must be respected...

Страница 5: ...6 kW 6 28 A 9 A 66 4 dBA 38 4 dBA 45 kg PowerPAC 2M 1 64 kW 7 8 kW 7 34 A 10 A 67 4 dBA 39 4 dBA 46 kg PowerPAC 3M 2 2 kW 11 kW 10 5 A 14 5 A 68 dBA 40 dBA 60 kg Controller On Off or Stand by press a...

Страница 6: ...t pump must be installed at a minimum distance from the pool This distance is defined by the locally valid electrical regulations In France the standard NF C 15 100 section 702 specifies that the unit...

Страница 7: ...ter flow rate 2 8 3 5 5 m3 h head loss 0 12 to 0 15 bar Electrical The electrical power supply to the heat pump must be protected with a fuse and isolator switch not provided in compliance with standa...

Страница 8: ...nd monitoring of the pool heating requirements even when the filter system has been switched off by the timer Connection of the Priority Heating function Use terminals 16 and 17 to control filter pump...

Страница 9: ...Note in the aforementioned configuration the heat pump is not yet supplied with pool water 2 Switch on the filter system 3 Progressively close valve V1 in order to increase the filter pressure to 150...

Страница 10: ...en 5 and 5 C the fan is switched off The compressor and fan restart after a time period of 2 to 5 minutes varies according to the compressor stoppage time If the ambient temperature drops below 5 C th...

Страница 11: ...matic if less than 4 dbP or dHP faults in one hour or press the key if the message dSr is blinking Alternating with the pool water temperature Water flow rate sensor fault ST4 Sensor defective or disc...

Страница 12: ...a high pressure spray Ensure no foreign bodies obstruct the fan grid Annual by a qualified and authorised technician Carry out the regular maintenance tasks refer to paragraph above Check the target...

Страница 13: ...G DIAGRAM With an aim to continuous improvement the products may be modified without prior notice Edition of 09 08 A IMPORTANT Elimination or shunting of a safety or remote control device automaticall...

Страница 14: ...e eliminated or neutralised Your appliance is reaching the end of its working life You would like to get rid of it or replace it Please do not throw it into the dustbin or into your local council s se...

Страница 15: ...N o t e s N o t e n A a n t e k e n i n g N o t a s N o t a...

Страница 16: ...N o t e s N o t e n A a n t e k e n i n g N o t a s N o t a...

Страница 17: ...t be carried out with total respect of valid safety regulations and acceptable professional practice recuperation of refrigerant nitrogen brazing etc All brazing work must be carried out by a qualifie...

Страница 18: ...yst mes de chauffage et de d shumidification de piscines En s appuyant sur le savoir faire technologique et l exp rience de PSA Zodiac vous apporte la garantie d appareils de tr s haut niveau tant dan...

Страница 19: ...hank you for trusting us and enjoy your bath at 28 C Please take a little time to fill in this guarantee form with your pool adviser Your details may be treated according to the law Informatique et ci...

Страница 20: ...n de s rie Type and serial number Utilisateur Owner Installateur installer Station service agr e PSA Technical support Garantie guaranty Date de livraison Delivery date Date de mise en route Date of...