background image

H03620

00.D2.EN

 

 

2013/03

 

 

10

 

4.2.2

 

Troubleshooting

 

 

 

all

 

soldering

 

work

 

must

 

be

 

carried

 

out

 

by

 

a

 

someone

 

qualified

 

to

 

do

 

so.

 

 

replacement

 

pipes

 

must

 

always

 

be

 

made

 

of

 

copper

 

in

 

compliance

 

with

 

standard

 

NF

 

EN

 

12735

1.

 

 

leak

 

detection;

 

pressure

 

test:

 

-

 

never

 

use

 

oxygen

 

or

 

dry

 

air,

 

risk

 

of

 

fire

 

or

 

explosion,

  

-

 

use

 

dry

 

nitrogen

 

or

 

the

 

mixture

 

of

 

nitrogen

 

and

 

refrigerant

 

indicated

 

on

 

the

 

information

 

plate,

  

-

 

the

 

test

 

pressure

 

for

 

both

 

the

 

high

 

and

 

low

 

pressure

 

circuits

 

must

 

not

 

exceed

 

42

 

bar.

 

 

the

 

high

 

pressure

 

circuit

 

pipes

 

are

 

made

 

of

 

copper

 

and

 

have

 

a

 

diameter

 

equal

 

to

 

or

 

greater

 

than

 

1’’5/8.

 

A

 

certificate

 

as

 

indicated

 

in

 

§2.1

 

in

 

compliance

 

with

 

standard

 

NF

 

EN

 

10204

 

will

 

be

 

requested

 

from

 

the

 

supplier

 

and

 

filed

 

in

 

installation

 

technical

 

documentation.

 

 

technical

 

data

 

relative

 

to

 

the

 

safety

 

requirements

 

of

 

the

 

various

 

applicable

 

directives

 

must

 

be

 

indicated

 

on

 

the

 

information

 

plate.

  

 

This

 

data

 

must

 

be

 

recorded

 

in

 

the

 

installation

 

instructions

 

for

 

the

 

device

 

which

 

are

 

included

 

in

 

the

 

installation

 

technical

 

file

:

 

model,

 

code,

 

serial

 

number,

 

maximum

 

and

 

minimum

 

OT,

 

OP,

 

year

 

of

 

manufacture,

 

EC

 

label,

 

manufacturer’s

 

address,

 

refrigerant

 

and

 

weight,

 

electrical

 

parameters,

 

thermo

dynamic

 

and

 

acoustic

 

performances.

 

 

4.3

 

Available

 

accessories

 

 

Name

 

PAC

 

NET

 

Wintering

 

cover

 

Remote

 

control

 

unit

 

Technical

 

room

 

kit

 

Representation

  

 

 

 

 

4.4

 

Recycling

 

 

This

 

symbol

 

means

 

that

 

your

 

device

 

must

 

not

 

be

 

thrown

 

in

 

the

 

bin.

 

The

 

device

 

must

 

be

 

collected

 

by

 

a

 

selective

 

system

 

in

 

view

 

of

 

re

use,

 

recycling

 

or

 

similar.

 

Any

 

substances

 

it

 

may

 

contain

 

which

 

are

 

potentially

 

dangerous

 

to

 

the

 

environment

 

shall

 

be

 

eliminated

 

or

 

neutralised.

 

Request

 

information

 

on

 

recycling

 

procedures

 

from

 

your

 

retailer.

 

 

5.

 

Troubleshooting

 

 

5.1

 

Display

 

of

 

the

 

regulator

 

 

Display

 

Designation

 

Cause

 

Solution

 

Reset

 

 

Protection

 

of

 

heat

 

exchanger

 

in

 

cold

 

mode

 

Temperature

 

of

 

ST4

 

sensor

 

too

 

low

 

Wait

 

for

 

the

 

surrounding

 

temperature

 

to

 

become

 

warmer

 

Automatic

 

 

High

 

temperature

 

defect

 

for

 

the

 

air

 

heat

 

exchanger

 

in

 

"cooling"

 

mode

 

Temperature

 

probe

 

ST3

 

above

 

60°C

 

or

 

evaporator

 

scaled

 

up

 

Clean

 

the

 

evaporator,

 

if

 

the

 

defect

 

persists,

 

contact

 

an

 

approved

 

technician

 

Automatic

 

if

 

temperature

 

probe

 

ST3

 

is

 

below

 

45°C

 

 

Phase

 

order

 

defect

 

(only

 

on

 

three

phased

 

models)

 

1.

 

wiring

 

incorrect

 

on

 

the

 

supply

 

terminal

 

board

 

of

 

the

 

device,

 

2.

 

modification

 

of

 

phase

 

order

 

by

 

electrical

 

supplier,

 

3.

 

temporary

 

failure

 

of

 

one

 

or

 

several

 

phases

 

1.

 

reverse

 

the

 

phases

 

on

 

the

 

supply

 

terminal

 

board

 

(without

 

power

 

to

 

the

 

device)

 

2,

 

3,

 

4.

 

contact

 

your

 

electricity

 

provider

 

to

 

find

 

out

 

if

 

modifications

 

have

 

been

 

made

 

to

 

your

 

equipment.

 

Switch

 

the

 

power

 

supply

 

off

 

or

 

press

 

 

 
 
 
 
 

Содержание PF Premium 11T

Страница 1: ...EN PF Premium 11M TSR 11T TSR 15M TSR 15T TSR 6M 8M 11M 11T 13M Instructions for installation and use English H03620 00 C 2012 02 374274014 01 More languages on www zodiac poolcare com...

Страница 2: ...sically and mentally who are familiar with the operating instructions by reading the user guide Individuals who do not satisfy these requirements must not handle the device so as to avoid exposure to...

Страница 3: ...malfunctions 12 5 3 FAQ 12 6 Product registration 13 Information included at the end of the manual wiring diagrams dimensions description compliance certificate 1 Information before installation 1 1 G...

Страница 4: ...dity of 70 according to French standard NF 414 protection class IP 24 refrigerant gas R410A refrigerant charge see product information plate class I degree of pollution 2 overvoltage category II 2 Ins...

Страница 5: ...ack of the packing box 2 4 Hydraulic connections Check the direction of the pipework connection see Dimensions in the appendix The connection include a 50 PVC rigid pipe from a by pass on the swimming...

Страница 6: ...utside of the European community with an outer diameter between 9 and 18 mm use the cable gland to run the supply cable into the device 2 5 2 Connections the electrical supply cable must not be expose...

Страница 7: ...re is below the required temperature thanks to a dry contact without max I polarity 8 A between terminals 1 2 alarm option to connect a relay to the alarm contact thanks to a dry contact without max I...

Страница 8: ...ent ambient air temperature adequate inadequate operation indicator During heating or air conditioning On standby until operating command received defrost indicator Defrost in progress On off button b...

Страница 9: ...s on stand by press on for 3 seconds will appear for 2 seconds and for 3 seconds and the water and set point temperatures will be displayed a 2 minute delay will start set the required water temperatu...

Страница 10: ...vacuate the impurities which could block it clean the outside of the unit with a solvent free product A specific PAC NET cleaning kit is available as an optional extra see 4 3 check that the water con...

Страница 11: ...performances 4 3 Available accessories Name PAC NET Wintering cover Remote control unit Technical room kit Representation 4 4 Recycling This symbol means that your device must not be thrown in the bi...

Страница 12: ...r Switch the power supply off or press Water flow rate sensor defect ST4 Sensor out of order or disconnected connector J8 white on plate A1 Replace or reconnect the sensor Switch the power supply off...

Страница 13: ...n error message appearing The heat pump does defrost cycles from time to time This is normal if the outdoor temperature is below 10 C The evaporator is clogged Clean the evaporator see 4 1 the heat pu...

Страница 14: ...hecked all of the above points contact your installer Where should my water treatment system be positioned with respect to the heating system The water treatment system chlorinator salt chlorinator et...

Страница 15: ...H03620 00 D2 EN 2013 03 1 Wiring diagram PFP 6M 8M 11M 13M...

Страница 16: ...H03620 00 D2 EN 2013 03 2 PFP 11T...

Страница 17: ...H03620 00 D2 EN 2013 03 3 PFP 11M TSR...

Страница 18: ...H03620 00 D2 EN 2013 03 4 PFP 15M TSR...

Страница 19: ...H03620 00 D2 EN 2013 03 5 PFP 11T TSR 15T TSR...

Страница 20: ...ard for display C1 Fan capacitor C2 Compressor capacitor C3 Filter D1 Progressive starter H Defrost resistance HP High pressure switch LP Low pressure switch J1 Flow rate switch M1 Fan motor M2 Compre...

Страница 21: ...EN 2013 03 7 Dimensions and description Base Front pannel cowl Technical door Back pannel Post Grid Regulator 1 water pool inlet 1 water pool outlet Evaporator Stuffing box PFP weight 6 51 8 52 11 63...

Страница 22: ...t your retailer ZODIAC is a registered trademark of Zodiac International S A S U used under license Votre revendeur your retailer Zodiac pool Care Europe BP 90023 49180 St Barth l my d Anjou cedex Fra...

Отзывы: