2.5.4

 

Connection

 

of

 

options

 

 

 

use

 

cables

 

with

 

a

 

cross

section:

 

of

 

2

 

x

 

0.75

 

mm²

 

or

 

larger,

 

of

 

type

 

RO2V

 

or

 

equivalent

 

in

 

countries

 

outside

 

of

 

the

 

European

 

Community,

 

with

 

an

 

outer

 

diameter

 

of

 

between

 

8

 

and

 

13

 

mm.

 

 

 

Remove

 

the

 

lid

 

(just

 

above

 

the

 

cable

 

gland)

 

and

 

fit

 

the

 

supplied

 

cable

 

glands

 

to

 

run

 

the

 

cables

 

into

 

the

 

device.

 

The

 

cables

 

used

 

for

 

the

 

optional

 

features

 

and

 

the

 

power

 

supply

 

must

 

be

 

held

 

together

 

using

 

a

 

collar

 

inside

 

the

 

device,

 

just

 

after

 

the

 

cable

 

gland.

 

 

Any

 

incorrect

 

connection

 

to

 

terminals

 

1

 

to

 

8

 

could

 

damage

 

the

 

regulator

 

and

 

void

 

the

 

warranty.

  

Never

 

supply

 

the

 

motor

 

of

 

the

 

filter

 

pump

 

directly

 

using

 

terminals

 

1

2.

 

If

 

orange

 

terminals

 

1

 

to

 

8

 

are

 

serviced,

 

back

 

current

 

may

 

exist.

 

 

 

"heating

 

priority"

 

-

 

connection

 

to

 

control

 

the

 

operation

 

of

 

the

 

filter

 

pump

 

(by

 

a

 

minimum

 

5

minute

 

cycle

 

every

 

hour,

 

with

 

filtration

 

maintained

 

if

 

the

 

pool

 

temperature

 

is

 

below

 

the

 

required

 

temperature),

 

 

-

 

thanks

 

to

 

a

 

dry

 

contact

 

(without

 

max.

 

I

 

polarity

 

=

 

8

 

A)

 

 

-

 

between

 

terminals

 

1

2,

 

 

alarm

 

-

 

option

 

to

 

connect

 

a

 

relay

 

to

 

the

 

alarm

 

contact,

 

 

-

 

thanks

 

to

 

a

 

dry

 

contact

 

(without

 

max.

 

I

 

polarity

 

=

 

2

 

A)

 

 

-

 

between

 

terminals

 

5

6,

 

 

remote

 

on/off

 

control

  

-

 

thanks

 

to

 

a

 

zero

potential

 

free

 

contact,

 

without

 

230

 

V

  ‐ 

50

 

Hz

 

polarity,

 

connect

 

the

 

cable

 

to

 

the

 

busbar

 

between

 

terminals

 

7

8,

  

-

 

activate

 

the

 

command

 

by

 

pressing

 

 

for

 

5

 

seconds

 

when

 

regulation

 

is

 

not

 

on

 

standby:

 

 

then

 

,

 

then

 

press

 

3

 

seconds

 

on

 

 

:

 

,

 

select

 

“Yes”

 

using

 

key

 

,

 

then

 

validate

 

by

 

pressing

 

 

:

 

,

 

press

 

 

to

 

exit.

 

 

                    

 

 

 

remote

 

control

 

unit

 

-

 

to

 

control

 

the

 

operation

 

of

 

the

 

heat

 

pump

 

remotely,

 

 

-

 

refer

 

to

 

the

 

instructions

 

for

 

the

 

remote

 

control

 

unit

 

for

 

connections.

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

filter

 

timer

 

 

power

 

contactor

 

(3

pole

 

or

 

2

pole),

 

supplying

 

the

 

filter

 

pump

 

A1

A2:

 

supply

 

to

 

the

 

power

 

contactor

 

coil

 

of

 

the

 

filter

 

pump

 

 

independent

 

connecting

 

cable

 

for

 

the

 

"heating

 

priority"

 

function

 

 

terminal

 

 

independent

 

connecting

 

cable

 

for

 

alarm

 

contact

 

relay

 

 

alarm

 

contact

 

relay

 

 

remote

 

on/off

 

switch

 

 

independent

 

connecting

 

cable

 

for

 

remote

 

on/off

 

control

 

Phase

 

Phase

 

Neutral

Neutral

 

Содержание PF Premium 11M TSR

Страница 1: ...EN PF Premium 11M TSR 11T TSR 15M TSR 15T TSR 6M 8M 11M 11T 13M Instructions for installation and use English H03620 00 C 2012 02 374274014 01 More languages on www zodiac poolcare com...

Страница 2: ...sically and mentally who are familiar with the operating instructions by reading the user guide Individuals who do not satisfy these requirements must not handle the device so as to avoid exposure to...

Страница 3: ...malfunctions 12 5 3 FAQ 12 6 Product registration 13 Information included at the end of the manual wiring diagrams dimensions description compliance certificate 1 Information before installation 1 1 G...

Страница 4: ...dity of 70 according to French standard NF 414 protection class IP 24 refrigerant gas R410A refrigerant charge see product information plate class I degree of pollution 2 overvoltage category II 2 Ins...

Страница 5: ...ack of the packing box 2 4 Hydraulic connections Check the direction of the pipework connection see Dimensions in the appendix The connection include a 50 PVC rigid pipe from a by pass on the swimming...

Страница 6: ...utside of the European community with an outer diameter between 9 and 18 mm use the cable gland to run the supply cable into the device 2 5 2 Connections the electrical supply cable must not be expose...

Страница 7: ...re is below the required temperature thanks to a dry contact without max I polarity 8 A between terminals 1 2 alarm option to connect a relay to the alarm contact thanks to a dry contact without max I...

Страница 8: ...ent ambient air temperature adequate inadequate operation indicator During heating or air conditioning On standby until operating command received defrost indicator Defrost in progress On off button b...

Страница 9: ...s on stand by press on for 3 seconds will appear for 2 seconds and for 3 seconds and the water and set point temperatures will be displayed a 2 minute delay will start set the required water temperatu...

Страница 10: ...vacuate the impurities which could block it clean the outside of the unit with a solvent free product A specific PAC NET cleaning kit is available as an optional extra see 4 3 check that the water con...

Страница 11: ...performances 4 3 Available accessories Name PAC NET Wintering cover Remote control unit Technical room kit Representation 4 4 Recycling This symbol means that your device must not be thrown in the bi...

Страница 12: ...r Switch the power supply off or press Water flow rate sensor defect ST4 Sensor out of order or disconnected connector J8 white on plate A1 Replace or reconnect the sensor Switch the power supply off...

Страница 13: ...n error message appearing The heat pump does defrost cycles from time to time This is normal if the outdoor temperature is below 10 C The evaporator is clogged Clean the evaporator see 4 1 the heat pu...

Страница 14: ...hecked all of the above points contact your installer Where should my water treatment system be positioned with respect to the heating system The water treatment system chlorinator salt chlorinator et...

Страница 15: ...H03620 00 D2 EN 2013 03 1 Wiring diagram PFP 6M 8M 11M 13M...

Страница 16: ...H03620 00 D2 EN 2013 03 2 PFP 11T...

Страница 17: ...H03620 00 D2 EN 2013 03 3 PFP 11M TSR...

Страница 18: ...H03620 00 D2 EN 2013 03 4 PFP 15M TSR...

Страница 19: ...H03620 00 D2 EN 2013 03 5 PFP 11T TSR 15T TSR...

Страница 20: ...ard for display C1 Fan capacitor C2 Compressor capacitor C3 Filter D1 Progressive starter H Defrost resistance HP High pressure switch LP Low pressure switch J1 Flow rate switch M1 Fan motor M2 Compre...

Страница 21: ...EN 2013 03 7 Dimensions and description Base Front pannel cowl Technical door Back pannel Post Grid Regulator 1 water pool inlet 1 water pool outlet Evaporator Stuffing box PFP weight 6 51 8 52 11 63...

Страница 22: ...t your retailer ZODIAC is a registered trademark of Zodiac International S A S U used under license Votre revendeur your retailer Zodiac pool Care Europe BP 90023 49180 St Barth l my d Anjou cedex Fra...

Отзывы: