Zodiac Jandy Pro Series JE1500T Скачать руководство пользователя страница 19

Page 17

ENGLISH

  

 

 

Jandy

® 

Pro Series JE Heat Pumps   

|

   Installation and Operation Manual

Figure 12.  aqualink rs to Jandy pro series JE Heat pump - t-stat (2 wire) connection

Heat Pump

Green - Enabled
Red - On

Heat Pump Connections

Terminals 1 and 2 

Connector for Low

Voltage Wires 

DIP Switches

S1 and S2

S1

S2

RESET

SERVICE

TIME OUT

FIL

TER PUM

P

AUX 

1

AUX 

2

AUX 

3

AUX 

4

AUX 

5

AUX 

6

AUX 

7

RS6 & RS8 ONLY

RS8 ONLY

HEATER

SOLAR

POOL MODE

SPA MODE

SPA DRAIN

SPA FILL

AUTO

6 5 4 3 2 1

10 9 8 7 6 5 4 3 2 1

4 3 2 1

4 3 2 1

S1

S2

OFF    ON

OFF    ON

1 2 3 4 5 6 7 8

1 2 3 4

Thu January, 2009  3:03 PM

AquaLink Touch

Home

Menu

OneTouch

Help

Back

Status

Photos

Power

FILTER

PUMP

SPA

POOL
HEAT

Pool Temp

86º

Air Temp

78º

SPA

HEAT

AUX1

AUX2

AUX3

Other

Devices

On/Off

Green - Enabled
Red - On

5. 

Use 22 gauge 4-conductor wire (Zodiac

®

 Part No. 

4278) to run between the heat pump and the RS 

control, and match the wire color order.

6. 

The wires coming from the Jandy Pro Series JE 

heat pump can be “doubled up” on the red terminal 

bar with the four (4) wires coming from the indoor 

controller.

notE

  If you need to install more than two (2) wires in 

each terminal, order a Zodiac

®

 Multiplex PCB 

Kit, which includes the Multiplex Board (Zodiac 
Part No. 6584). Never put more than two (2) 
wires into each of the pins of the terminal bar.

7. 

Check all wiring, then apply power to both the 

heat pump and the RS control system. Operation 

can be verified in either Service or Auto mode. See 

the RS Control System manual for instructions 

about operation.

When the Jandy Pro Series JE heat pump is first 

powered and there is an RS control connected to the 

heat pump, the display on the heat pump will show 

“JandY rEMotE onlinE pusH MEnu to 
disaBlE”

. When the JE heat pump is online with 

the RS control, all functionality of the control on the 

heat pump is disabled. The heat pump functions can be 

controlled only at the RS unit. 
To temporarily use the heat pump controls, press 

the 

MEnu

 button. The message 

“JandY rEMotE 

onlinE pusH MEnu to disaBlE” 

will disappear 

from the heat pump display. All functionality has now 

been returned to the control on the heat pump. In this 

mode the RS unit is no longer controlling the heat 

pump. 

To return the functionality to the RS unit, cycle (turn off 

and then turn on) the power to the heat pump, or press 

the 

MEnu

 button for 5 seconds to enter the User Setup 

Mode and then enable the Zodiac Remote. 

notE 

If connecting more than two (2) items to the RS 
Power Center red, 4-pin connector, a Multiplex 
PCB is required.

Connection to a secondary user interface

1.   Turn off the power to the heat pump.
2.   Remove the five (5) screws that attach the front 

panel to the heat pump and remove the cover to 

the junction box. See Figure 10.

3.   Run four (4) 22 AWG solid copper wires into the 

conduit labeled “Low Voltage Connection” located 

on the lower right hand side of the heat pump. See 

Figure 10. The wires may be up to 300 feet  

(91.4 m) in length.

4.   Connect the wires to the 4 position terminal on 

the upper left hand corner of the Power Interface 

PC Board, labeled “User Interface1”. The wires 

will be added to the existing wiring to the User 

Interface installed on the heat pump.

5.    Ensure the wiring is consistent when connecting 

the wires to the second User Interface. For 

example, BK goes to BK, O goes to O, etc.

6.   Re-install the junction box cover and service 

access panel and restore power to the heat pump.

Содержание Jandy Pro Series JE1500T

Страница 1: ...on of R410A refrigerant In the event no such state or local requirement exists the installer or maintainer must be a professional with sufficient experience in pool equipment installation and maintena...

Страница 2: ......

Страница 3: ...Spa Connection 3 Wire Connection 16 Figure 11b AquaLink RS or Remote TSTAT Connection 2 Wire Connection 16 Figure 12 AquaLink RS to JE Heat Pump 17 Figure 13 JE Heat Pump Connection to Power Center 1...

Страница 4: ...Page 2 ENGLISH Jandy Pro Series JE Heat Pumps Installation and Operation Manual...

Страница 5: ...rovides installation and operation instructions for the Jandy Pro Series JE models of heat pumps Read these installation and operation instructions completely before proceeding with the installation C...

Страница 6: ...here possible shelter the pool from prevailing winds with well trimmed hedges or other landscaping cabanas or fencing 7 The use of an automatic pool cover if installed provides a valuable safety featu...

Страница 7: ...installation is required to assure safe operation The requirements for Zodiac heat pumps include the following 1 Field assembly if required 2 Appropriate site location and clearances 3 Sufficient air...

Страница 8: ...ing Scroll Scroll Scroll CABINET ABS REFRIGERANT 64 Oz R410A 78 Oz R410A 78 Oz R410A 78 Oz R410A 118 Oz R410A 126 Oz R410A 118 Oz R410A 126 Oz R410A REFRIGERANT HIGH PRESSURE ALARM 600 PSI reset to 46...

Страница 9: ...ed indoors means of condensate disposal must be provided Indoor installation requires factory consultation Lawn Sprinklers Keep lawn sprinkler heads from spraying on the heat pump to prevent corrosion...

Страница 10: ...ater connections are no more than 10 feet below the pool water surface or no more than 5 feet above it See instructions for pressure switch adjustment Section 5 6 in the heat pump start up section of...

Страница 11: ...ng on multiple heat pump installations must be done in parallel see Figures 6 and 7 An equal flow of water to each heat pump is important for optimum operation Note It may be necessary to adjust water...

Страница 12: ...the front cover of the junction box 4 Electrical supply lines must be run through watertight conduit Route the wires and conduit through the knock out designated for high voltage on the right side of...

Страница 13: ...CAL FEEDER TO POOL OR SPA CHECK VALVE OR OPTIONAL CHLORINE GENERATION SYSTEM JANDY AQUAPURE SHOWN MANUAL BYPASS VALVE CHEMICAL LOOP POOL HEATER VENT FOR INDOOR INSTALLATION ONLY HEATER HEAT PUMP FROM...

Страница 14: ...and Operation Manual Figure 6 Two 2 Heat Pump Plumbing Layout Figure 7 Four 4 Heat Pump Plumbing Layout Manual Bypass Valve 2 PVC 3 PVC Optional Isolation Valves From Filter To Pool Manual Bypass Valv...

Страница 15: ...BK BL BK BK BR W BL Y Y BL W BR HIGH REFRIGERANT PRESS SWITCH LOW REFRIGERANT PRESS SWITCH WATER TEMP DEFROST TEMP BK R R L1 L2 Y Y Y Y BK W R R FAN MOTOR BR BR W BK W W W W W R R GROUND GR GR R REVE...

Страница 16: ...GR Y GROUND POWER BOARD COMPRESSOR FAN MOTOR WATER PRESSURE SWITCH USER INTERFACE REVERSING VALVE OPTIONAL HIGH REFRIGERANT PRESSURE SWITCH LOW REFRIGERANT PRESSURE SWITCH CONTACTOR W W W W W L1 L2 L3...

Страница 17: ...a Remote Pool Off Spa Selector 3 Wire Connection Install the Remote Pool Off Spa Selector 1 Turn off the power to both the pool spa control system and the heat pump unit 2 Remove the screws that attac...

Страница 18: ...Setup mode press and hold the MENU POOL and SPA buttons for 5 seconds NOTE The display will revert back to OFF after one minute since the last key press 3 Press the Up or Down button to display REMOTE...

Страница 19: ...trol connected to the heat pump the display on the heat pump will show JANDY REMOTE ONLINE PUSH MENU TO DISABLE When the JE heat pump is online with the RS control all functionality of the control on...

Страница 20: ...re control When that happens the heat pump will automatically shut off but the filter pump will keep running 5 2 Operating the Controller Your new Jandy Pro Series JE heat pump is controlled by an adv...

Страница 21: ...LL will not be displayed if the unit is not provided with chiller You can change the temperature set point by pressing the Up or Down button Repeatedly press the Up or Down button until you reach the...

Страница 22: ...de 2 To enter the User Setup mode press and hold the MENU button for 5 seconds 3 To select spa timer use the Up or Down button to scroll through to display SELECT USER SETUP SPA TIMER Press the MENU b...

Страница 23: ...mum requirement of 30 gpm 114 lpm after the direction fitting or elbow has been installed Make sure the pool filter is clean before making any pressure switch adjustment A dirty filter will restrict t...

Страница 24: ...em which has been under water Zodiac recommends that you inspect your heat pump on a regular basis and especially after abnormal weather conditions The following basic guidelines are suggest ed for yo...

Страница 25: ...t gas enters the heat exchanger where the water extracts the heat The pump pulls in cool pool water which in turn converts the hot gas back into a liquid refrigerant and starts the cycle over again Th...

Страница 26: ...run and control board displays FAULT NO FLOW Verify circulating pump is on and all necessary valves are in the correct positions Verify filter and skimmers are clean Check water level in pool Tempora...

Страница 27: ...sure builds too high the high pressure switch will open causing the heat pump to shut off immediately The control will sense this fault condition and shut off the compressor until the switch re closes...

Страница 28: ...pansion Valve 1500 R0575000 15 Thermal Expansion Valve 2000 2500 R0575100 15 Thermal Expansion Valve 3000 R0575200 16 Air Temperature Sensor All R0575300 17 High Pressure Switch All R0575400 18 Low Pr...

Страница 29: ...mps Installation and Operation Manual 9 3 Zodiac JE 1500 Heat Pumps Exploded View C 1 2 3 4 5 6 7 8 9 10 11 12 20 21 DETAIL C SCALE 1 8 13 14 15 16 17 18 19 33 See Figure 19 for detail Figure 16 Zodia...

Страница 30: ...allation and Operation Manual 9 4 Zodiac JE 2000 JE2500 JE3000 Heat Pumps Exploded View C 1 2 3 4 5 6 7 9 8 10 12 20 11 21 23 DETAIL C SCALE 1 8 15 14 13 17 18 22 19 33 See Figure 20 for detail Figure...

Страница 31: ...ation and Operation Manual 9 5 Zodiac JE Single Phase Electric Box 9 6 Zodiac JE Three Phase Electric Box Figure 18 Zodiac JE Single Phase Electric Box Figure 19 Zodiac JE Three Phase Electric Box 24...

Страница 32: ...acPoolSystems com Zodiac Pool Systems Canada Inc 2115 South Service Road West Unit 3 Oakville ON L6L 5W2 1 888 647 4004 www ZodiacPoolSystems ca ZODIAC is a registered trademark of Zodiac Internationa...

Отзывы: