1.2 I Hydraulic connections
•
The device will be connected with a Ø50 PVC pipe, using the half union connectors supplied (see § “5.1 I Description”),
to the pool's filtration circuit, after the filter and before the water treatment.
•
Respect the direction of hydraulic connection.
•
A by-pass must be installed to make it easier to work on the device.
: water entry valve
: by-pass valve
: water exit valve
: water entry adjustment valve
(optional)
: water exit adjustment valve
(optional)
: water treatment
* minimum distance
Connection to a standard filtration circuit
•
To evacuate the condensation, fit a Ø18 pipe inside the grooved elbow to be mounted under the device's base.
Condensation drainage orientation
Tip: condensation drainage
Caution, several litres of water must be drained from your device each day. We strongly recommend
connecting the drainage to the sewers
We also recommend tilting the device slightly backwards (using the adjustable studs) for better condensation
drainage.