❶ Installation
1.1 I Selecting the location
• When installed with and protected by an appropriate Residual Current Device (RCD) having a
maximum trip current rating of 30mA, the appliance must be installed at 2 metres, minimum,
from the surrounding edge of the pool.
• If an appropriate RCD is not installed with the appliance, the appliance must be installed at a
minimum distance of 3.5 metres from the edge of the pool.
• Do not lift the appliance using the casing, handle it from the base.
•
For outdoor installation, provide free space around it (see § “1.2 I Hydraulic connections”).
•
For indoor installation, the device must be equipped with the plant room kit.
•
Place the device on its anti-vibration studs (integrated under its base, height adjustable) on a stable, solid and level
surface,
•
This surface must be able to bear the weight of the device (in particular in the case of installation on a roof, a balcony
or any other support).
The device must not be installed:
•
With the blowing towards a permanent or temporary obstacle (awning, brushwood, etc.) less than 5 metres away,
•
Within range of water or mud jets, sprays or run-off (take the effect of the wind into account),
•
Near a heat source or flammable gas,
• Near high frequency equipment,
•
In a location where it would be subject to snow build-up,
•
In a location where it might be flooded by the condensation produced by the device when operating.
Tip: reduce any noise annoyance from your heat pump
•
Do not install it under or towards a window.
•
Do not tilt it towards your neighbours.
•
Install it in a clear space (the sound waves are reflected on surfaces).
•
Install an acoustic screen around the heat pump, respecting the distances.
•
Install 50cm of flexible PVC pipe at the heat pump water input and output (stops vibrations).
•
Increase the filtration time by 50% and activate "Eco Silence" mode. The heat pump will run for longer
with less power, but much more quietly and with an improved COP (energy savings). Only use the "Eco
Silence" mode to maintain the desired temperature.