6
1.4.5 Electric connections
1.4.5.1 Voltage and protection
the electrical supply of the appliance must come from a protection and switching device (not
supplied) complying with the standards and regulations in force in the country.
an additional protection may be required during installation to guarantee the overvoltage category
II,
the unit is designed for connection to a general power supply with full earth and neutral or neutral
earth systems,
electrical protection: by circuit-breaker (curve D) or fuse (Am) (for calibre, see §1.4.5.3), and with a
30 mA differential trip switch at the head of the supply line (circuit-breaker or switch),
1.4.5.2 Connections
See placing § “dimensions and description” in the appendix
1.4.5.3 Cable sections
supply cable section: for cables of a maximum length of 20 metres (calculation base: 5A/mm²),
must be checked and adapted depending on installation conditions.
PF
Maximum current
consumption
Cable saction
Electrical protection
A
mm²
A
6M
9
3 x 2.5
3G2.5
16
8M
10
3 x 2.5
3G2.5
16
11M
14.5
3 x 2.5
3G2.5
16
13M
16.1
3 x 4
3G4
20
15M
21.9
3 x 6
3G6
25
1.4.5.4 “Priority Heating” function
Objective: to keep the
pool water at the required temperature
, independent of the filtering time (the
heat pump triggers the operation of the filter every hour):
- the pool temperature > required temperature = the heat pump stops the filter system after 5
minutes.
- the pool temperature < required temperature = the heat pump switches on and keeps the filter
pump running until the correct temperature is attained.
The appliance must be earthed.
Risk of electrical shock inside the device. Only a qualified and experienced technician
can install the device’s cables.
If the power cable is damaged, it must be replaced by a qualified technician or in a
Zodiac Pool Care Europe technical station.
acceptable tolerance of tension variation: ± 6% (while working),
electric cables shall be fixed,
use
cable suited for outdoor use
,
of type RO2V or equivalent in countries outside
the European Community
, and with an outer diameter between 9 and 18 mm,
use the stuffing box to bring the supply cable into the appliance
Prior to any operation, check that the voltage on the identification plate of the
appliance corresponds to the mains voltage provided on site.
Configuration of supply terminal rail
single-phase 230V-50Hz with phase (L)
+ neutral (N) + Earth
Fuse holder F1
3.15 A Type T
(timed) 250Vac
Earth terminal green/yellow
Содержание FP 8M
Страница 17: ...N o t e s N o t e n A a n t e k e n i n g N o t a s N o t a...
Страница 18: ...1 Electric diagram PF 6M 8M...
Страница 19: ...2 PF 11M 13M 15M...
Страница 22: ...N o t e s N o t e n A a n t e k e n i n g N o t a s N o t a...
Страница 23: ...N o t e s N o t e n A a n t e k e n i n g N o t a s N o t a...