Page 13 

ENGLISH

  

 

Zodiac FloPro

 E3 3-Speed Variable Pump   

|

   Installation & Operation Manual

2. 

Remove the carbon face seal half from the 

impeller shaft (See Figure 15). This is a 

spring-loaded seal. Grasp the portion of the 

seal closest to the impeller body and pull the 

seal off, using a twisting motion.

3. 

Remove the motor from the backplate, 

following the steps in Section 6.3.4, Motor 

Replacement.

4. 

Place the backplate o-ring side down and 

force the ceramic seal out using a screwdriver 

or drift.

5. 

Turn the backplate o-ring side up and insert 

the new ceramic seal side into the backplate. 

Use great care to press the seal in squarely 

with your fingers. The ceramic is easily 

damaged and must be pressed in using only 

your fingers or soft tools. Do not use any 

lubricant other than water or soapy water.

6. 

Install the backplate by following the relevant 

steps in Section 6.3.2.1, Impeller Reassembly.

7. 

Install the motor by following the steps in 

Section 6.3.4, Motor Replacement.

6.3.4  Motor Replacement

 WARNING

To ensure continued safety and reliable operation, 

Zodiac

®

 requires that you replace the motor with a 

motor listed in the spares list that has the identical 

HP rating and service factor (Zodiac approved 

only).

1. 

Have a qualified service technician or 

electrician properly disconnect the electrical 

wiring at the pump motor. 

 WARNING

ELECTRICAL SHOCK HAZARD

Turn off power to the FloPro pump electrical circuit 

before starting the procedure. Wait five (5) minutes 

after power is disconnected before opening motor. 

Failure to comply may cause a shock hazard, 

resulting in severe personal injury or death.

2. 

To detach the pump housing from the motor, 

see Section 6.3.2, Impeller Removal and 

Replacement. 

3. 

Note the alignment of the backplate to the 

motor, as shown in Figure 20. Place the 

backplate motor assembly o-ring side down, 

unscrew the four 9/16” screws, and remove 

the motor. 

4. 

Place the motor on the backplate so that the 

opening in the motor faces the bottom of the 

backplate. The electronics controller on the 

motor should be at the 12 o’clock position. 

5. 

Replace the four (4) bolts and washers 

holding the backplate to the motor and torque 

to 20 Nm. See Figure 20.

6. 

To reassemble the backplate assembly to 

the housing, see Section 6.3.2.1, Impeller 

Reassembly.

7. 

If the pump is located above the water level 

of the pool, remove the lid and fill the basket 

with water before starting the pump.

8. 

To help prevent an air leak into the system, 

remove any debris around the lid seal seat.

9. 

Hand-tighten

 the lid to make an air tight seal.  

Do not use any tools to tighten the lid.

10.  Open the pressure release valve on the filter 

and make sure it is clean and ready for 

operation. 

11.  Have a qualified service technician or 

electrician properly connect the electrical 

wiring at the pump motor.

12.  Turn on the electrical power to the pump 

motor using your controller and check the 

system for normal operation.

13.  Once all the air has left the filter, close the 

pressure relief valve.

NOTE

  Zodiac recommends that the mechanical seals be 

replaced at the same time the motor is replaced. 

See Section 6.3.3, Mechanical Seal Replacement, 

for details.

Figure 20.  Backplate Assembly 

Motor 

Hardware

Kit 

Motor 

Backplate

Backplate

Hardware

Содержание FloProE3

Страница 1: ...s product read and follow all warning notices and instructions that accompany this product Failure to follow warning notices and instructions may result in property damage personal injury or death Imp...

Страница 2: ...ines 5 Section 2 General Description 5 2 1 Introduction 5 2 2 Description 5 Section 3 Installation Information 5 3 1 Plumbing 5 3 2 Electrical Installation 6 3 3 Conduct Pressure Testing 6 Section 4 O...

Страница 3: ...edition of ANSI ASME A112 19 8 WARNING To reduce the risk of injury do not permit children to use this product WARNING To reduce the risk of property damage or injury do not attempt to change the back...

Страница 4: ...essure for test must NOT EXCEED 35 PSI Water temperature for test must NOT EXCEED 100 F 38 C Limit test to 24 hours After test visually check system to be sure it is ready for operation NOTICE These p...

Страница 5: ...ection 3 Installation Information 3 1 Plumbing 3 1 1 Preparation Information 1 Upon receipt of the pump check the carton for damage Open the carton and check the pump for concealed damage such as crac...

Страница 6: ...tion must not be in the same area as the pool pump filter and other equipment 3 3 Conduct Pressure Testing WARNING When pressure testing a system with water air is often trapped in the system during t...

Страница 7: ...r close the pressure release valve 7 The pump should prime The time it takes to prime will depend on the elevation and length of pipe used on the suction supply pipe See Section 3 1 3 3 Installation R...

Страница 8: ...ace Do not force it into place 6 Remove the lid seal and remove debris around the lid seal seat as this can allow air to leak into the system Clean the lid seal and place it on the lid 7 Replace the l...

Страница 9: ...pump Loosen both unions and slide the pump out of the way Remove clean and re install both union o rings Reposition the pump next to the piping and secure the union nuts to the pump With clean union o...

Страница 10: ...vere personal injury or death may occur if the pump starts while your hand is inside the pump 1 Turn off the pump Switch off the circuit breaker to the pump motor 2 Remove the lid and basket 3 Look in...

Страница 11: ...g toward the ceramic ring in the backplate CAUTION Very Important To prevent damage to the seal grasp the lower portion of the seal opposite the carbon face when installing it Fan Cover Bolts 6 Motor...

Страница 12: ...an even manner Once all the screws are snug torque in the same order to 13 Nm 9 If the pump is located above the water level of the pool remove the lid and fill the basket with water before starting t...

Страница 13: ...otor Failure to comply may cause a shock hazard resulting in severe personal injury or death 2 To detach the pump housing from the motor see Section 6 3 2 Impeller Removal and Replacement 3 Note the a...

Страница 14: ...4900 3 IMPELLER WFHP 1 0HP R0735100 4 DIFFUSER WFHP R0735400 5 MECHANICAL SEAL CARBON CERAMIC 1 SET R0735500 6 E3 PUMP BODY WFHP R0755000 7 FOOT MOTOR FHP SERIES WFHPM AUSTRALIA A0133001 8 LID W LOCKI...

Страница 15: ...Page 15 ENGLISH Zodiac FloPro E3 3 Speed Variable Pump Installation Operation Manual 7 3 Exploded View 8 9 12 6 11 18 10 4 14 4 11 3 2 5 2 3 4 6 13 14 15 2 2 16 1 17 7 1 4 15 19...

Страница 16: ...d trademark of Zodiac International S A S U used under license All trademarks referenced herein are the property of their respective owners H0394700 Rev D Zodiac Group Australia 219 Woodpark Road Smit...

Отзывы: