manualshive.com logo in svg
background image

18

19

ZODIAC

 FloPro ssPump installation & Operation Manual

W70913

WET END IMPELLER ASSY 1.1KW

1

7

W70914

DIFFUSER, PUMP, WFHPM

1

8

W70915

PUMP BACKPLATE

1

2

W70916

PUMP FOOT MOTOR

1

3

W70917

PUMP SLEEVE

1

28

W70918

PUMP ASSY. BODY FLOPRO

1

4

W70919

WET END BACKPLATE O'RING

1

24

W70920

WET END DIFFUSER O'RING

1

23

W70921A

PUMP SEAL MECHANICAL (SPRING LOADED DRIVE BAND ASSY)

1

5

W70921B

PUMP SEAL MECHANICAL (SEAT/MATTING RING)

1

6

W70922

WET END SCREW, MOTOR TO BACKPLATE

4

14

W70923

WET END SCREW, BACKPLATE TO PUMP

6

16

W70924

PUMP WASHER, 3/8, SS SERIES N, TYPE B, ANSI B18.2.1

10

15

W70925

WET END DIFFUSER SCREW

1

17

W70926

WET END UNION ASSEMBLY

2

1, 21, 22

W041321

REDUCING BUSH-GREY

2

7.2 Performance curves

Zodiac FloPro ssPump - Head vs Flow Rate

7.3. Physical and Operational Specifications

Figure 9. FloPro ssPump Dimensions (without Base or Spacers)

Zodiac FLOPRO Single Speed 

Pump Specs

0.6kW

0.75kW

1.1kW

Model

FLOPRO 0.6kW

FLOPRO 0.75kW 

FLOPRO 1.1kW 

Motor -Type

Single Phase 

Single Phase 

Single Phase 

Pump -kW

0.6kW / 0.75HP

0.75kW / 1.0HP

1.1kW / 1.5HP

Motor -kW

0.8kW

1.0kW

1.4kW

Motor -Voltage (Alternating Current) 

and Frequency (Hertz)

V230 AC                         

Hz50

V230 AC                         

Hz50

V230 AC                         

Hz50

Motor -Amps Maximum Amax

3.6A

4.6A

6.2A

Motor -Revolutions Per Minute RPM

2820

2820

2820

Motor -Capacitor

16

µ

F (450V)

20

µ

F (450V)

30

µ

F (450V)

Insulation Class

F    

F

F

International Protection  Marking

IP44

IP44

IP44

Motor -Frame Size

80

80

80

Overload Protection

130°C - 

Autoreset

130°C - 

Autoreset

130°C - 

Autoreset

Motor -Bearing Drive end

6204 DDU

6204 DDU

6204 DDU

Motor -Bearing Non Drive end

6204 DDU

6204 DDU

6204 DDU

Water Temperature Max.

35°C

35°C

35°C

Flow -Litre per minute Q(L/min)

285-205 L/min

340-240 L/min

390-260 L/min

Flow -Litre per minute Maximum Qmax

290 L/min

350 L/min

400 L/min

Head -Metres H(m)

1-12m

1-14m

1-16m

Head -Maximum Hmax

15m

17m

20m

Flow Rate Q (L/m)

H

ea

d

 H

(m)

Zodiac 

FloPro 1.1kW

Zodiac 

FloPro 0,75kW

Zodiac 

FloPro 0.6kW

Содержание FLOPRO SS

Страница 1: ...Installation and Operation Manual ...

Страница 2: ...onal injury or death Improper installation and or operation will void the warranty ATTENTION INSTALLER This manual contains important information about the installation operation and safe use of this product This information should be given to the owner operator of this equipment Contents Section 1 Important Safety Instructions 1 1 Safety Instructions 1 2 Pool Pump Suction Entrapment Prevention Gu...

Страница 3: ...th swimming pool equipment E g filters The pump is to be installed in accordance with the relevant requirements of the South African wiring rules Occupational Health and Safety Act 1993 Act no 85 of 1993 schedule electrical installation regulations Also refer to the installation instructions relating to the swimming pool equipment of which the pump will be an integral part The pump is to be suppli...

Страница 4: ...ing will be achieved if the pump is installed as close as possible to the water level of the pool 2 Zodiac Pool Care SA Pty Ltd recommends that the pump and other circulation equipment be located more than 1 5 metres from the water Choose a location that will minimize turns in the piping 3 The pump must be placed on a solid foundation that will not vibrate To further reduce the possibility of vibr...

Страница 5: ...y length of time will cause severe damage to both the pump and motor and will void the warranty If this is a new pool installation make sure all piping is clear of construction debris Check the filter for proper installation verifying that all connections and clamps are secure according to the manufacturer s recommendations To avoid risk of property damage severe personal injury or death verify th...

Страница 6: ...immer baskets pump basket and other screens are clean Clean as necessary Check filter and clean as necessary Check valve positions Adjust as necessary NOTE Multiple pieces of equipment operating at one time for example waterfalls spa jets and surface returns may affect the cleaning system and prevent it from working properly Check the cleaning system manual to ensure that the system is adjusted ac...

Страница 7: ...ter from reaching the pump Drain the water from the pump by loosening the unions or removing the drain plugs 3 Using a 14mm wrench loosen the bolts connecting the pump body to the motor backplate See Figure 1 Figure 1 Remove the Pump body 4 Pull the motor and backplate out of the pump body Remove the pump body o ring The impeller is connected to the motor shaft 5 Using a No 1 Phillips star screwdr...

Страница 8: ... the carbon face seal half from the impeller sleeve See Figure 5 This is a spring loaded seal Grasp the portion of the seal closest to the impeller body and pull the seal off using a twisting motion Ceramic Face Seal Backplate Seal Figure 5a Mechanical Seal CAUTION VERY IMPORTANT Grasp the lower portion of the seal opposite the carbon face when installing the seal or it will be damaged NOTE To ass...

Страница 9: ...peration Zodiac requires that you replace the motor with a motor that has the identical kW rating and service factor To avoid the risk of property damage severe personal injury or death turn off the pump and switch off the circuit breaker to the pump motor before beginning this procedure 1 To disassemble the pump housing from the motor follow steps 1 through 8 in Section 6 2 2 Impeller Removal 2 R...

Страница 10: ...ac FLOPRO Single Speed Pump Specs 0 6kW 0 75kW 1 1kW Model FLOPRO 0 6kW FLOPRO 0 75kW FLOPRO 1 1kW Motor Type Single Phase Single Phase Single Phase Pump kW 0 6kW 0 75HP 0 75kW 1 0HP 1 1kW 1 5HP Motor kW 0 8kW 1 0kW 1 4kW Motor Voltage Alternating Current and Frequency Hertz V230 AC Hz50 V230 AC Hz50 V230 AC Hz50 Motor Amps Maximum Amax 3 6A 4 6A 6 2A Motor Revolutions Per Minute RPM 2820 2820 282...

Страница 11: ...ZODIAC CUSTOMER CARE CENTRE Zodiac Group South Africa Customer care line 0860 887 665 Email customer care zodiac com www zodiac co za ...

Отзывы: