8.7  Reversing

CAUTION

Adjusting your cell reversal times will result in voiding 

of warranty. You must consult with Zodiac on 1300 763 

021 or your local pool care professional before making 

any adjustments.

The chlorinator uses a smart polarity reversal 

system. Periodic polarity reversal will prevent 

scaling of the cell plates. The time between each 

reversal is factory set at 5 hours. This setting 

is optimal for most water conditions. However, 

Depending on the calcium hardness of the water, 

you may need to adjust the reversal time. More 

calcium in the water will require less time between 

reversals. Water with less calcium can be given 

more time between reversals. Shorter reversal 

times will cause more wear of your cell plates. The 

polarity reversal interval can be adjusted from 2 to 

8 hours in 1-hour steps.
1.  Press 

.

2.  Use 

 to select “Reversing” then press  .

3.  Use 

 to select set hours then press  .

4.  Press  

 to exit.

<

-REVERSING

-HELP MENU

-LANGUAGE

MAIN MENU

<

INVERSION PERIOD

5 HOURS

REVERSING TIME

During reversal, chlorination is stopped for a few 

minutes. No message is displayed on the screen. 

Normal operation will resume after the reversal.

8.8  Slave Mode

Slave mode relinquishes control of the chlorination 

function to an external controller. The controller 

must be connected to the “Slave” connection point 

in the low voltage raceway see Table 5 and Figure 

10 for wiring details.
Boost and Low modes will remain operational from the 

controller. However, SWC programs will be deactivated. 

Chlorination output will be maintained at 100%.
1.  Connect the external controller at the slave 

connection point in the ow voltage raceway 

see Table 5 and Figure 10 for wiring details.

2.  Press 

.

3.  Use 

 to select “Slave Mode” 

then press  .

4.  Use 

 to select “YES” or “NO” then press  .

5.  Press  

 to exit.

<

-SLAVE MODE

-REVERSING

-HELP MENU

-LANGUAGE

MAIN MENU

<

SLAVE MODE

ACTIVATE?

- YES

- NO

<

23:04 ON

SLAVE MODE

<

23:04 OFF

SLAVE MODE

Slave mode only controls the chlorination. Filtration 

pump, AUX, lights and other functions are still valid.
Pressing 

 will take priority over Slave mode. 

If a Dual Link module is installed, the ORP function 

is overridden by the slave mode. The pH regulation 

is still valid.
LOW / COVER / BOOST modes takes priority over 

Slave mode

8.9  Help Menu

The chlorinator will automatically notify you of any 

problems by displaying error messages. To help 

with the understanding of these messages, the 

controller has a troubleshooting assistance menu 

which gives the meanings and the action to take to 

solve the problem.
1.  Press 

.

2.  Use 

 to select “Help Menu” then press  .

3.  Use 

 to select the error message 

then press  .

4.  The display will automatically scroll through 

a certain number of suggested solutions to 

explain what to do. Once automatic scrolling is 

complete, the chlorinator automatically returns 

to the “Troubleshooting” menu.

5.  Press  

 to exit.

Содержание eXO Series

Страница 1: ...talling this product read and follow all warning notices and instructions that accompany this product Failure to follow warning notices and instructions may result in property damage personal injury o...

Страница 2: ...le on the Controller 11 5 1 Install the POD Kit 11 5 2 Drill the Pipe 11 5 3 Install the POD 11 5 4 Install the POD Cap 12 5 5 Install and Calibrate the Sensor 12 5 6 Install the pH Down Intake and In...

Страница 3: ...es have a high potential for causing fetal damage during the early months of pregnancy pregnant or possibly pregnant women should limit spa water temperatures to 38 C Before entering a spa or hot tub...

Страница 4: ...lectric appliance such as a light telephone radio or television within 3 5 metres of a spa or hot tub The use of alcohol drugs or medication can greatly increase the risk of fatal hyperthermia in hot...

Страница 5: ...AC 50 Hz Electric power 200 W Protection index IP43 Flow through the cell 5m3 ph 18m3 ph Max pressure in the cell 2 75 bar Operating water temperature 10 C 40 C Table 3 Salt Chlorinator System Specifi...

Страница 6: ...n Power Drill 7 mm Drill Bit Hammer Drill Bit only necessary to drill into brick or concrete Pencil or Marking Pen Flat Head Screwdriver Pozidiv Screwdriver Small Flathead or Slotted Screwdriver 2 4 2...

Страница 7: ...NOT OVERTIGHTEN 8 Double check cell orientation The cell inlet is closest to the cell electrical lead Figure 3 Plumbing Cell Only pH Minus CAUTION Never store acid directly underneath any equipment a...

Страница 8: ...the sensor body 3 Secure the sensor and o ring with the screw clamp provided DO NOT OVERTIGHTEN Figure 7 Install Temperature Sensor 4 3 Electrical Connections WARNING FOR YOUR SAFETY This product must...

Страница 9: ...nection of the pH sensing PCBA PUMP Input Connection of the pH pump for pH Link module CELL Output 1 Connection of the electrolysis cell UI Output Connection of the user interface TEMP Input 3 Connect...

Страница 10: ...PUMP CELL UI TEMP FLOW MAINS PUMP 230V iAL RS485 VSP RS485 COVER SLAVE AUX 2 12 24V AUX 230V L N N L H0632100 Rev A CABLE IDENTIFICATION TNG EU SENS PUMP CELL UI TEMP FLOW MAINS PUMP 230V iAL RS485 V...

Страница 11: ...pH down injection pipe 5 1 Install the POD Kit 1 Make sure power to the controller is OFF 2 For optimal performance the POD must be installed On a 30 cm length of rigid 50 mm or 63 mm PVC pipe As far...

Страница 12: ...tool until snug Do not overtighten 5 5 Install and Calibrate the Sensor 1 Install the sensor holder into the correct port on the POD cap Sensor Holder Cap Plug Figure 16 Sensor Holder Installation 2...

Страница 13: ...ve on the POD 3 Remove the threaded cap from the pump outlet right 4 Thread tubing through the hole in the cap connect the tubing to the nipple on the module and reattach the threaded cap NOTE For a b...

Страница 14: ...cid is a hazardous chemical that may cause burns lesions and irritations Handle with extreme care using protective equipment gloves goggles coveralls Refer to the substance SDS sheet for more informat...

Страница 15: ...so dium carbonate Add sodium bicarbonate Add calcium chloride Add cyanuric acid Add salt or minerals To Decrease Add muriatic acid Add muriatic acid or dry acid Partially drain and refill pool Partia...

Страница 16: ...Power 1 Press to enter Standby mode 2 Press again to start chlorination and filtration 3 Press and hold for 3 seconds to turn the controller off 7 2 2 Language 1 Press 2 Use to select Language then pr...

Страница 17: ...atically be activated when the cover is closed The Cover mode message and the output percentage are displayed on the screen 23 04 ON COVER MODE 10 Cover mode will stop as soon as the cover is complete...

Страница 18: ...L GRN On the Pump 4 Ensure the pump DIP switches are in the correct position as follows 1 up 2 up 3 down 4 down 5 up 5 Press 6 Use to select Filter Pump then press 7 Use to select Variable Speed then...

Страница 19: ...ator 8 2 1 Assign Lights 1 Press 2 Use to select Aux Light then press 3 Use to select Assign Lights then press 4 Use to select Aux 2 then press 5 Use to select Yes then press 6 Use to select White Lig...

Страница 20: ...he pH sensor into the pH 7 buffer solution 9 Press while Start is selected 10 Press while Go to Step 2 is selected 11 Rinse the pH sensor with tap water 12 Insert the pH sensor into the pH 4 buffer so...

Страница 21: ...The pH dosing pump can be directly activated directly in order to perform a five minute operating test WARNING Hydrochloric acid is a hazardous chemical that may cause burns lesions and irritations Ha...

Страница 22: ...Reset Timers then press The selected timers will be reset to 00 00 8 6 2 Operation With an External Timer In order for the controller to operate with an external timer All controller programs must be...

Страница 23: ...Use to select Programming then press 3 Use to select SWC then press 4 Use to select SWC Timer 1 or SWC Timer 2 then press 5 Use to select the hour for the SWC on time then press 6 Use to select the mi...

Страница 24: ...connection point in the low voltage raceway see Table 5 and Figure 10 for wiring details Boost and Low modes will remain operational from the controller However SWC programs will be deactivated Chlori...

Страница 25: ...10 Winterizing The chlorinator has a protective system which will limit sanitizer production during unfavorable operating conditions such as cold water or lack of salt Active winterizing leaves the f...

Страница 26: ...l back down in order to protect the electric circuits If the box is installed outdoors protect it from direct sunlight Chlorination will automatically resume once the temperature has fallen back down...

Страница 27: ...Page 27 eXO Installation Manual NOTES...

Страница 28: ...A S U used under license All trademarks referenced herein are the property of their respective owners 2018 Zodiac Pool Systems Inc H0642500 REV A Zodiac Pool Care South Africa Pty Ltd P O Box 79 Bergv...

Отзывы: