Page 25
Page 24
eXO
®
| Installation Manual
8.7 Reversing
CAUTION
Adjusting your cell reversal times will result in voiding
of warranty. You must consult with Zodiac on 1300 763
021 or your local pool care professional before making
any adjustments.
The chlorinator uses a smart polarity reversal
system. Periodic polarity reversal will prevent
scaling of the cell plates. The time between each
reversal is factory set at 5 hours. This setting
is optimal for most water conditions. However,
Depending on the calcium hardness of the water,
you may need to adjust the reversal time. More
calcium in the water will require less time between
reversals. Water with less calcium can be given
more time between reversals. Shorter reversal
times will cause more wear of your cell plates. The
polarity reversal interval can be adjusted from 2 to
8 hours in 1-hour steps.
1. Press
.
2. Use
to select “Reversing” then press .
3. Use
to select set hours then press .
4. Press
to exit.
<
-REVERSING
-HELP MENU
-LANGUAGE
MAIN MENU
<
INVERSION PERIOD
5 HOURS
REVERSING TIME
During reversal, chlorination is stopped for a few
minutes. No message is displayed on the screen.
Normal operation will resume after the reversal.
8.8 Slave Mode
Slave mode relinquishes control of the chlorination
function to an external controller. The controller
must be connected to the “Slave” connection point
in the low voltage raceway see Table 5 and Figure
10 for wiring details.
Boost and Low modes will remain operational from the
controller. However, SWC programs will be deactivated.
Chlorination output will be maintained at 100%.
1. Connect the external controller at the slave
connection point in the ow voltage raceway
see Table 5 and Figure 10 for wiring details.
2. Press
.
3. Use
to select “Slave Mode”
then press .
4. Use
to select “YES” or “NO” then press .
5. Press
to exit.
<
-SLAVE MODE
-REVERSING
-HELP MENU
-LANGUAGE
MAIN MENU
<
SLAVE MODE
ACTIVATE?
- YES
- NO
<
23:04 ON
SLAVE MODE
<
23:04 OFF
SLAVE MODE
Slave mode only controls the chlorination. Filtration
pump, AUX, lights and other functions are still valid.
Pressing
will take priority over Slave mode.
If a Dual Link module is installed, the ORP function
is overridden by the slave mode. The pH regulation
is still valid.
LOW / COVER / BOOST modes takes priority over
Slave mode
8.9 Help Menu
The chlorinator will automatically notify you of any
problems by displaying error messages. To help
with the understanding of these messages, the
controller has a troubleshooting assistance menu
which gives the meanings and the action to take to
solve the problem.
1. Press
.
2. Use
to select “Help Menu” then press .
3. Use
to select the error message
then press .
4. The display will automatically scroll through
a certain number of suggested solutions to
explain what to do. Once automatic scrolling is
complete, the chlorinator automatically returns
to the “Troubleshooting” menu.
5. Press
to exit.