Page 17
Page 16
eXO
®
| Installation Manual
ignored for the duration of the Boost mode. Once
Boost mode completes, the controller and filter
pump will resume programmed operations.
NOTE:
If the device is equipped with a Dual Link
module, the Boost mode will not take the ORP
value into account. The Boost mode takes
priority over the ORP regulation
1. Press
.
23:04 ON
BOOST MODE 23:59
2. If the controller is in Low/Cover mode you will
need to confirm that you want Boost mode to
override Cover or Low mode settings.
7.2.5
Low Mode
Low mode is designed to reduce chlorine
production in situations where the pool is covered
or when pool use is limited. Chlorine production
needs will be lower when pool use is low and/or
when pool water is not exposed to UV rays etc.
Low mode output can be set in the main menu
settings for Low mode. Low can be set from
0%-30% in 10% increments. Programs are still
active while the controller is in Low/Cover mode.
1. To manually enter Low mode press
.
2. To exit Low mode press
again.
23:04 ON
LOW MODE 10%
7.2.6
Cover Mode
If the pool is equipped with a compatible electric roller
cover, this can be connected to the controller in order
to automatically reduce chlorination upon closing the
cover, this is known as Cover mode, see Table 5 and
Figure 10 for wiring details. Chlorination will resume
at the level determined by the programming upon
opening the compatible electric cover.
Cover mode output can be set in the main menu
settings for Low mode. Low can be set from
0%-30% in 10% increments. Programs are still
active while the controller is in Low/Cover mode.
Check that the cover is compatible and connected
to the chlorinator.
Cover mode will automatically be activated when
the cover is closed. The Cover mode message and
the output percentage are displayed on the screen.
23:04 ON
COVER MODE 10%
Cover mode will stop as soon as the cover is
completely open.
If the controller is equipped with a Dual Link
module we do not recommend connecting the
Cover mode. More specifically, chlorination is
managed via the Dual Link module. In cases where
the Cover mode is connected in the presence of
a Dual Link module: chlorination will take place
upon closing the roller cover, even if the ORP
measurement is greater than the setpoint value.
7.2.7
Cold Water Protection
In addition to recording and displaying the water
temperature, the temperature sensor is used to
protect the cell, which is sensitive to cold water.
The temperature displayed on the top left of the
home screen will begin to flash at 15°C.
23:04 ON
15°
When water temperature is under or equal to 15°C,
chlorine production automatically switches to the
level defined in Low/Cover mode.
When water temperature is under or equal to 10°C,
chlorine production is stopped. The absence of
chlorination at this temperature is not hazardous,
as bacterial development is slowed in cold water.
In addition to the flashing temperature, a “LOW
TEMPERATURE” message is alternately
displayed.
When the temperature goes over 10°C again, the
output percentage will be set to Low/Cover.
When the temperature goes over 15°C again,
chlorination resumes its level of operation
configured using programs.
7.2.8
Locking the Controller
The controller can be locked, thus deactivating the
buttons on the user interface panel. Simultaneously
press and hold the and buttons for 3
seconds. This function can be accessed from any
screen/menu.
Locking the controller automatically returns the user to
the home screen. To unlock the controller, press and
hold the and buttons for another 3 seconds.