eXO

®

 |   Installation Manual

5.6  Install the pH Down Intake and 

Injection lines.

Intake line  

(Pump to  

pH down)

Injection line 

(Pump to POD)

Figure 19. 

pH- Pump Configuration

The pump rotates in a clockwise direction. Acid is 

fed into the left side of the pump (via the Intake 

line) and injected into the POD from the right side 

(via the Injection line). 

CAUTION

: For safety reasons, install the Injection line 

before the Intake line to ensure pH is not 

accidentally dosed into the system before all 

connections are made. 

 

Never store acid directly underneath any 

equipment as fumes will cause corrosion 

and resulting damage can void your 

warranty. It is recommended to store your 

acid container in a safe, protected well 

ventilated area.

flow direction 

(  pump inlet,   Injection)

 

Figure 20.  pH-  Pump Port

5.6.1 

Install the Injection Line  

1.  Remove the protective cover from the pump.

2.  Cut a section of the plastic tubing that has 

adequate length to reach from the injection valve 

at the pump to the non-return valve on the POD.

3.  Remove the threaded cap from the pump 

outlet (right).

4.  Thread tubing through the hole in the cap, 

connect the tubing to the nipple on the module 

and reattach the threaded cap.

NOTE

:  For a better fit, soften both ends of the tubing by 

immersing in warm water.

5.  Remove the threaded cap from the POD 

intake valve. 

6.  Thread tubing through the hole in the cap, 

connect the tubing to the nipple on the POD 

and reattach the threaded cap.

5.6.2 

Install the pH Down Intake Line

1.  Cut a section of the plastic tubing that has 

adequate length to reach from the pH down 

reservoir to the pump.

2.  Remove the threaded cap from 

the pump inlet (left side). 

3.  Pass one end of the tubing through the 

threaded cap and attach tubing to the nipple 

on the pump inlet.

4.  Remove the cap from the pH down container.

5.  Thread tubing through the hole in the cap 

through the ceramic weight.

6.  Remove the nut from the blue 

compression fitting.

7.  Pass the tubing through the nut and attach it 

to the nipple on the compression fitting.

8.  Reattach the threaded nut.

9.  Put the weighted end of the hose into the pH 

down reservoir.

10.  Secure the pH down cap tightly on the container.
11.  Replace the protective cover on the pump.

Содержание eXO Series

Страница 1: ...talling this product read and follow all warning notices and instructions that accompany this product Failure to follow warning notices and instructions may result in property damage personal injury o...

Страница 2: ...le on the Controller 11 5 1 Install the POD Kit 11 5 2 Drill the Pipe 11 5 3 Install the POD 11 5 4 Install the POD Cap 12 5 5 Install and Calibrate the Sensor 12 5 6 Install the pH Down Intake and In...

Страница 3: ...es have a high potential for causing fetal damage during the early months of pregnancy pregnant or possibly pregnant women should limit spa water temperatures to 38 C Before entering a spa or hot tub...

Страница 4: ...lectric appliance such as a light telephone radio or television within 3 5 metres of a spa or hot tub The use of alcohol drugs or medication can greatly increase the risk of fatal hyperthermia in hot...

Страница 5: ...AC 50 Hz Electric power 200 W Protection index IP43 Flow through the cell 5m3 ph 18m3 ph Max pressure in the cell 2 75 bar Operating water temperature 10 C 40 C Table 3 Salt Chlorinator System Specifi...

Страница 6: ...n Power Drill 7 mm Drill Bit Hammer Drill Bit only necessary to drill into brick or concrete Pencil or Marking Pen Flat Head Screwdriver Pozidiv Screwdriver Small Flathead or Slotted Screwdriver 2 4 2...

Страница 7: ...NOT OVERTIGHTEN 8 Double check cell orientation The cell inlet is closest to the cell electrical lead Figure 3 Plumbing Cell Only pH Minus CAUTION Never store acid directly underneath any equipment a...

Страница 8: ...the sensor body 3 Secure the sensor and o ring with the screw clamp provided DO NOT OVERTIGHTEN Figure 7 Install Temperature Sensor 4 3 Electrical Connections WARNING FOR YOUR SAFETY This product must...

Страница 9: ...nection of the pH sensing PCBA PUMP Input Connection of the pH pump for pH Link module CELL Output 1 Connection of the electrolysis cell UI Output Connection of the user interface TEMP Input 3 Connect...

Страница 10: ...PUMP CELL UI TEMP FLOW MAINS PUMP 230V iAL RS485 VSP RS485 COVER SLAVE AUX 2 12 24V AUX 230V L N N L H0632100 Rev A CABLE IDENTIFICATION TNG EU SENS PUMP CELL UI TEMP FLOW MAINS PUMP 230V iAL RS485 V...

Страница 11: ...pH down injection pipe 5 1 Install the POD Kit 1 Make sure power to the controller is OFF 2 For optimal performance the POD must be installed On a 30 cm length of rigid 50 mm or 63 mm PVC pipe As far...

Страница 12: ...tool until snug Do not overtighten 5 5 Install and Calibrate the Sensor 1 Install the sensor holder into the correct port on the POD cap Sensor Holder Cap Plug Figure 16 Sensor Holder Installation 2...

Страница 13: ...ve on the POD 3 Remove the threaded cap from the pump outlet right 4 Thread tubing through the hole in the cap connect the tubing to the nipple on the module and reattach the threaded cap NOTE For a b...

Страница 14: ...cid is a hazardous chemical that may cause burns lesions and irritations Handle with extreme care using protective equipment gloves goggles coveralls Refer to the substance SDS sheet for more informat...

Страница 15: ...so dium carbonate Add sodium bicarbonate Add calcium chloride Add cyanuric acid Add salt or minerals To Decrease Add muriatic acid Add muriatic acid or dry acid Partially drain and refill pool Partia...

Страница 16: ...Power 1 Press to enter Standby mode 2 Press again to start chlorination and filtration 3 Press and hold for 3 seconds to turn the controller off 7 2 2 Language 1 Press 2 Use to select Language then pr...

Страница 17: ...atically be activated when the cover is closed The Cover mode message and the output percentage are displayed on the screen 23 04 ON COVER MODE 10 Cover mode will stop as soon as the cover is complete...

Страница 18: ...L GRN On the Pump 4 Ensure the pump DIP switches are in the correct position as follows 1 up 2 up 3 down 4 down 5 up 5 Press 6 Use to select Filter Pump then press 7 Use to select Variable Speed then...

Страница 19: ...ator 8 2 1 Assign Lights 1 Press 2 Use to select Aux Light then press 3 Use to select Assign Lights then press 4 Use to select Aux 2 then press 5 Use to select Yes then press 6 Use to select White Lig...

Страница 20: ...he pH sensor into the pH 7 buffer solution 9 Press while Start is selected 10 Press while Go to Step 2 is selected 11 Rinse the pH sensor with tap water 12 Insert the pH sensor into the pH 4 buffer so...

Страница 21: ...The pH dosing pump can be directly activated directly in order to perform a five minute operating test WARNING Hydrochloric acid is a hazardous chemical that may cause burns lesions and irritations Ha...

Страница 22: ...Reset Timers then press The selected timers will be reset to 00 00 8 6 2 Operation With an External Timer In order for the controller to operate with an external timer All controller programs must be...

Страница 23: ...Use to select Programming then press 3 Use to select SWC then press 4 Use to select SWC Timer 1 or SWC Timer 2 then press 5 Use to select the hour for the SWC on time then press 6 Use to select the mi...

Страница 24: ...connection point in the low voltage raceway see Table 5 and Figure 10 for wiring details Boost and Low modes will remain operational from the controller However SWC programs will be deactivated Chlori...

Страница 25: ...10 Winterizing The chlorinator has a protective system which will limit sanitizer production during unfavorable operating conditions such as cold water or lack of salt Active winterizing leaves the f...

Страница 26: ...l back down in order to protect the electric circuits If the box is installed outdoors protect it from direct sunlight Chlorination will automatically resume once the temperature has fallen back down...

Страница 27: ...Page 27 eXO Installation Manual NOTES...

Страница 28: ...A S U used under license All trademarks referenced herein are the property of their respective owners 2018 Zodiac Pool Systems Inc H0642500 REV A Zodiac Pool Care South Africa Pty Ltd P O Box 79 Bergv...

Отзывы: