Zodiac EL Series Скачать руководство пользователя страница 14

Page 15

Page 14

EL Series Saltwater Chlorinator   |   Installation Manual

Section 11.  Troubleshooting

When there is an error condition, “ERROR” flashes on the display along with the error code. 

Fault Indication

Possible Cause

Solution

NO FLOW

 

Pump turned off/disconnected or valves 

closed

 

Blue wire disconnected from cell

 

Ensure valves/pump ON 

 

Connect BLUE sense wire to cell

LOW SALT

 

Salt level in pool has dropped too low 

 

Pool water temperature is low 

 

Cell has calcified

 

Cell has failed

 

Take sample of water to retailer and check salt level - add 

salt as recommended.

 

Add salt and turn chlorinator output down until the water is 

warmer.

 

Clean the cell.

 

Call for service

Display Blank

 

No power to controller

 

Fuse blown

 

Plug in controller and ensure main power available

 

Have a service technician replace fuse (2A slow blow)

Low/No Chlorine

in pool

 

Cables not connected to cell

 

Timer period too short

 

Chlorine output level too low

 

Filter needs backwashing

 

Ph too high

 

Pool stabiliser (cyanuric acid) too low

 

Salt level too low

 

Connect cables

 

Increase timer period (particularly during summer)

 

Increase chlorine output

 

Backwash filter

 

Balance pH level to 7.4 - 7.6

 

Increase stabiliser between 30 - 60 ppm.

 

Increase salt to above 6000 ppm

Clock loses time when main 

power is removed

 

Clock power backup failed

 

Call a technician

Timer is set to OFF in the 

TMR menu

 

The timer has been turned off

 

Use 

 to turn the timer back on. Adjust timer start and 

stop times to suit.

Table 5.  Troubleshooting      

Содержание EL Series

Страница 1: ...ational installation codes standards and any other local applicable regulations Before installing this product read and follow all warning notices and instructions that accompany this product Failure...

Страница 2: ...UGE READING WITH CLEAN FILTER PUMP MODEL HORSEPOWER FILTER MODEL CONTROL PANEL MODEL SERIAL NUMBER NOTES EQUIPMENT INFORMATION RECORD For full warranty terms and conditions and to register your warran...

Страница 3: ...1 Mount the Bracket 8 4 2 Electrical Connections 8 Section 5 Prepare and Balance the Pool 9 5 1 Water Chemistry Table 9 Section 6 Operation 10 6 1 User Interface Overview 10 6 2 Initial start Up 10 S...

Страница 4: ...mperatures are recommended for young children and when spa use exceeds 10 minutes b Since excessive water temperatures have a high potential for causing fetal damage during the early months of pregnan...

Страница 5: ...s or medication can greatly increase the risk of fatal hyperthermia in hot tubs and spas Water temperature in excess of 38 C may be hazardous to your health Attention Installer Install to provide drai...

Страница 6: ...Chlorinator System EL 25 EL 35 Nominal chlorine production 25 g h 35 g h Nominal output amps 4 4 A 5 8 A Required salt level 6000ppm Power supply voltage 230 240 VAC Protection index IP23 Flow through...

Страница 7: ...4 4 Glue the adapters directly onto the pipes 5 Ensure the o rings are seated properly on the adapters 6 Secure the cell to the plumbing by tightening the unions hand tight DO NOT OVERTIGHTEN 7 Doubl...

Страница 8: ...lectrical Connections WARNING FOR YOUR SAFETY This product must be serviced by a professional pool spa service technician as described on the front cover of this manual The procedures in this manual m...

Страница 9: ...utput Add buffer or soda ash so dium carbonate Add sodium bicarbonate Add calcium chloride Add cyanuric acid Add salt or minerals x To Decrease Add muriatic acid Add muriatic acid or dry acid Partiall...

Страница 10: ...nning within a timer period Auto Stopped indicates that the chlorinator is outside of a timer period 6 2 2 Set Clock 1 Press MENU and screen should display CLK Press ENTER 2 Press ENTER and the hour d...

Страница 11: ...n Season filtration time 12 14 hours per day Off Season filtration time 8 10 hours per day Filter Pump Programming 1 Press MENU 2 Press the MENU again and screen should display TMR Press ENTER 3 Use t...

Страница 12: ...rn pump and controller on 9 Confirm chlorine output and settings on the power pack Timer programs will be automatically retained Figure 8 Opening the Cell Section 9 Winterizing The chlorinator has a p...

Страница 13: ...replacement before further serious damage is sustained A small amount of regular care and attention to your pool equipment will help ensure long life and trouble free performance To protect against ex...

Страница 14: ...cell Call for service Display Blank No power to controller Fuse blown Plug in controller and ensure main power available Have a service technician replace fuse 2A slow blow Low No Chlorine in pool Cab...

Страница 15: ...Page 15 EL Series Saltwater Chlorinator Installation Manual NOTES...

Страница 16: ...registered trademark of Zodiac International S A S U used under license All other trademarks are the property of their respective owners H0720800_REVB Fluidra Group Australia Pty Ltd 219 Woodpark Roa...

Отзывы: