7.1  Programming/Timers

The controller has an internal operating timer that 

is used to define the length of time for the filter 

pump to operate during two separate time periods 

each day. 
In order to complete the timer program, it is 

necessary to enter and validate both ON and 

OFF times. If no timer is set, the filtration and / or 

chlorination will run continuously
The filtration operating times must be sufficient to 

correctly treat the water.

Example

 - single speed pump:

In Season filtration time: 8-10 hours per day.
Off Season filtration time: 4-5 hours per day.

Example

 - variable speed pump (when running at 

lower speeds):
In Season filtration time: 12-14 hours per day
Off Season filtration time: 8-10 hours per day

Filter Pump Programming

1.  Press MENU 

.

2.  Press the MENU 

 again and screen should 

display TMR. Press 

ENTER 

.

3.  Use 

 to adjust start time for TIMER1. 

Press ENTER 

.

4.  Use 

 to adjust the stop time for TIMER 

1. Press ENTER 

.

5.  Repeat for TIMER 2.

7.1.1 

User Operation Modes

The user mode buttons enable you to select and to 

automatically or manually control the chlorinator/

pump. Functions are as follows:
a.  POOL MODE:

•  Auto - Running/Stopped: The chlorinator/pump will 

run according to how you have set the timers.

•  Manual - Running: The chlorinator/pump will run 

continuously.

• 

Manual - Stopped: The chlorinator/pump will stay off 

continuously.

Maximum efficiency will be achieved from your 

chlorinator at the following levels:

•  Water temperature 15 Degrees – Salt level required 

is 6000 ppm.

•  Water Temperature 25 Degrees – Salt level required 

is 4,100 ppm.

Содержание EL Series

Страница 1: ...ational installation codes standards and any other local applicable regulations Before installing this product read and follow all warning notices and instructions that accompany this product Failure...

Страница 2: ...UGE READING WITH CLEAN FILTER PUMP MODEL HORSEPOWER FILTER MODEL CONTROL PANEL MODEL SERIAL NUMBER NOTES EQUIPMENT INFORMATION RECORD For full warranty terms and conditions and to register your warran...

Страница 3: ...1 Mount the Bracket 8 4 2 Electrical Connections 8 Section 5 Prepare and Balance the Pool 9 5 1 Water Chemistry Table 9 Section 6 Operation 10 6 1 User Interface Overview 10 6 2 Initial start Up 10 S...

Страница 4: ...mperatures are recommended for young children and when spa use exceeds 10 minutes b Since excessive water temperatures have a high potential for causing fetal damage during the early months of pregnan...

Страница 5: ...s or medication can greatly increase the risk of fatal hyperthermia in hot tubs and spas Water temperature in excess of 38 C may be hazardous to your health Attention Installer Install to provide drai...

Страница 6: ...Chlorinator System EL 25 EL 35 Nominal chlorine production 25 g h 35 g h Nominal output amps 4 4 A 5 8 A Required salt level 6000ppm Power supply voltage 230 240 VAC Protection index IP23 Flow through...

Страница 7: ...4 4 Glue the adapters directly onto the pipes 5 Ensure the o rings are seated properly on the adapters 6 Secure the cell to the plumbing by tightening the unions hand tight DO NOT OVERTIGHTEN 7 Doubl...

Страница 8: ...lectrical Connections WARNING FOR YOUR SAFETY This product must be serviced by a professional pool spa service technician as described on the front cover of this manual The procedures in this manual m...

Страница 9: ...utput Add buffer or soda ash so dium carbonate Add sodium bicarbonate Add calcium chloride Add cyanuric acid Add salt or minerals x To Decrease Add muriatic acid Add muriatic acid or dry acid Partiall...

Страница 10: ...nning within a timer period Auto Stopped indicates that the chlorinator is outside of a timer period 6 2 2 Set Clock 1 Press MENU and screen should display CLK Press ENTER 2 Press ENTER and the hour d...

Страница 11: ...n Season filtration time 12 14 hours per day Off Season filtration time 8 10 hours per day Filter Pump Programming 1 Press MENU 2 Press the MENU again and screen should display TMR Press ENTER 3 Use t...

Страница 12: ...rn pump and controller on 9 Confirm chlorine output and settings on the power pack Timer programs will be automatically retained Figure 8 Opening the Cell Section 9 Winterizing The chlorinator has a p...

Страница 13: ...replacement before further serious damage is sustained A small amount of regular care and attention to your pool equipment will help ensure long life and trouble free performance To protect against ex...

Страница 14: ...cell Call for service Display Blank No power to controller Fuse blown Plug in controller and ensure main power available Have a service technician replace fuse 2A slow blow Low No Chlorine in pool Cab...

Страница 15: ...Page 15 EL Series Saltwater Chlorinator Installation Manual NOTES...

Страница 16: ...registered trademark of Zodiac International S A S U used under license All other trademarks are the property of their respective owners H0720800_REVB Fluidra Group Australia Pty Ltd 219 Woodpark Roa...

Отзывы: