7.1 Programming/Timers
The controller has an internal operating timer that
is used to define the length of time for the filter
pump to operate during two separate time periods
each day.
In order to complete the timer program, it is
necessary to enter and validate both ON and
OFF times. If no timer is set, the filtration and / or
chlorination will run continuously
The filtration operating times must be sufficient to
correctly treat the water.
Example
- single speed pump:
In Season filtration time: 8-10 hours per day.
Off Season filtration time: 4-5 hours per day.
Example
- variable speed pump (when running at
lower speeds):
In Season filtration time: 12-14 hours per day
Off Season filtration time: 8-10 hours per day
Filter Pump Programming
1. Press MENU
.
2. Press the MENU
again and screen should
display TMR. Press
ENTER
.
3. Use
to adjust start time for TIMER1.
Press ENTER
.
4. Use
to adjust the stop time for TIMER
1. Press ENTER
.
5. Repeat for TIMER 2.
7.1.1
User Operation Modes
The user mode buttons enable you to select and to
automatically or manually control the chlorinator/
pump. Functions are as follows:
a. POOL MODE:
• Auto - Running/Stopped: The chlorinator/pump will
run according to how you have set the timers.
• Manual - Running: The chlorinator/pump will run
continuously.
•
Manual - Stopped: The chlorinator/pump will stay off
continuously.
Maximum efficiency will be achieved from your
chlorinator at the following levels:
• Water temperature 15 Degrees – Salt level required
is 6000 ppm.
• Water Temperature 25 Degrees – Salt level required
is 4,100 ppm.