Installing the Power Pack 

The power pack can be mounted on a wall or a post. If mounting on a post, center the Power Pack on a
flat panel of waterproof material at least 10" W x 18" H. If mounting on a wall, it can be secured by the
chassis (preferred method) or hang by cover.

Do not enclose the power pack in any box.

Do not install it above any heat source.

Install it a minimum of 10 feet from the pool edge. Refer to local building codes for requirements.

The power pack is hard-wired to 220V ONLY. Wire it to the "LOAD" side of the pump timer, so
that the chlorinator is powered only when the pump is powered.

The 3 ft input cable cannot be removed. (Removal will void ETL approval.) Use of a junction box
may be required in some installations.

Attach the yellow plug cap to the cell and replace the blue cap.

Wiring to an Automation System Controller

The LM3 Saltwater Chlorinator can run independently or be connected to a Pool Automation System. Two
connection methods are available.

Via an Auxiliary Relay at the Controller

(For installations using non-compatible controllers.)

Using this method the LM3 main power is connected to an auxiliary relay in the pool automation system
controller. The LM3 unit is switched on and off as determined by the controller.

The “Output Setting” and the selection of “Super Chlorinate” must be selected at the LM3 control panel.
The LM3 will retain these settings when switched on by the controller until they are manually changed.
The Super Chlorinate function will remain active for a total of 24 operating hours after 
being selected.

IMPORTANT: The LM3 should only have power when there is water flow and actuator valves
should never block the flow when power is on. Refer to the controller’s installation guide for
additional information.

Via a Communications Link

The LM3 has the capability of being interfaced with a number of controller units:

• Polaris EOS

• Jandy Aqualink RS* (REV K and L)

• Pentair IntelliTouch**

Using this method, main power is supplied to the LM3 via the controller’s PUMP output and a
communications link is made between the LM3 and the Pool Automation system.

Hardwire the LM3 power pack to the LOAD side of the pool pump relay. While wiring to the pump relay is
the preferred method, the LM3 main power can be wired to an auxiliary relay.

*Jandy Aqualink RS is a Registered Trademark of Water Pik Technologies, Inc.
**Pentair IntelliTouch is a Registered Trademark of Pentair Pool Products

Содержание CLEARWATER LM3 Series

Страница 1: ...LM3 Series Saltwater Chlorinator Installation Guide and Owner s Manual...

Страница 2: ...s operated under pressure and the pressure must be released before you begin work Please see your pump filter owner s manual for further instructions To avoid cell damage water pressure in the cell mu...

Страница 3: ...n System Controller 8 Check Salt No Flow Warnings to Controllers 8 Operation 9 Control Panel Functions 9 Control Panel Indicator Lights 10 Startup 10 Operating Tips 10 Maintenance 12 Regular Maintenan...

Страница 4: ...e filter and the Clearwater sanitizes the water to make it safe and sparkling clean Important To ensure the LM3 works at maximum efficiency regularly check and maintain the chemistry of your pool Wate...

Страница 5: ...ed Allow adequate drying time before turning on the chlorinator Important Note If pressure must be applied to the top of the shroud cell apply with hands on either end ONLY Flooded Plumbing Installati...

Страница 6: ...nected to an auxiliary relay in the pool automation system controller The LM3 unit is switched on and off as determined by the controller The Output Setting and the selection of Super Chlorinate must...

Страница 7: ...ers are as shown below Polaris Eos Jandy Aqualink RS Pentair IntelliTouch Note The wiring configurations are the same for both Jandy Rev K and Rev L controllers Note When connecting to the Jandy Aqual...

Страница 8: ...troller and the LM3 is lost the LM3 will continue operation as it was before the controller lost connection It will behave as a stand alone unit until the controller is reconnected or the user changes...

Страница 9: ...the chlorinator OFF when water through the cell stops To prevent cell damage and personal injury do not in any way interfere with this system as it has been designed for your protection Control Panel...

Страница 10: ...t will function again Note Operating the LM3 at reduced salt levels may shorten the life of the cell No Flow If light is ON it indicates no water flow in the cell The chlorine output will also turn of...

Страница 11: ...ing in hot sunny climates Extremely hot and sunny climates will require readings at the higher end of the range Refer to Stabilizer Requirements chart in Maintenance It is absolutely essential that th...

Страница 12: ...s to clouding of the water and reduces the amount of active chlorine which allows algae and germs to grow Lower the pH by adding muriatic acid to the pool water The acid demand indicated by your 4 in...

Страница 13: ...ents In some areas the calcium hardness of the source water may be unusually high High calcium hardness contributes to scale formation in the pool Sequestering agents may help to prevent this by keepi...

Страница 14: ...concentration For the exact requirements refer to the chart below Salt Requirements Pounds and KG of salt needed to raise level to 4000 PPM How to Add Salt Only 99 5 pure refined salt sodium chloride...

Страница 15: ...er s instructions Stabilizer Requirements Pounds and KG of stabilizer Cyanuric Acid needed to raise level to 80 PPM Manually Cleaning the Cell The self cleaning electrodes in the cell may occasionally...

Страница 16: ...electrode Apply a film of silicone lubricant to o ring just enough to make it shiny 10 Refit electrode into housing and tighten locking ring 11 Attach the output cable and the blue cap 12 Reset valve...

Страница 17: ...ash the filter then manually shock the pool to chlorine odor is evident destroy algae bacteria and other contaminants After shock treatment adjust pH to 7 2 7 6 ppm and check for 1 3 ppm chlorine leve...

Страница 18: ...F button A yellow light in the Chlorine Output indicator window lights when the unit is ON Check fuse and reset if necessary Check main power source Chlorine level is too high Use the OUTPUT button to...

Страница 19: ...mproper maintenance or installation accident improper application failure to follow all safety instructions or precautions Acts of God abnormal weather conditions damage from plants or animals and imp...

Страница 20: ...2007 Zodiac Pool Systems Inc All rights reserved TL 3000 11 07 ZODIAC POOL SYSTEMS INC 2620 Commerce Way Vista CA 92081 Tel 800 822 7933 Fax 877 327 1403 www zodiacpoolcare com...

Отзывы: