Mix a cleaning solution [one (1) part hydrochloric (muriatic) acid
to ten (10) parts water] in a suitable plastic vessel. To avoid
splash, always add muriatic acid to water rather than water to
acid. Solutions stronger than 1:10 will damage cell and
void warranty.
7.
Immerse electrode until plates are covered. Do not submerge
the entire cell.
8.
Allow the cleaning solution to sizzle for approximately 5 minutes.
If scrapping is necessary, use a soft object - never metal.
When electrodes are clean, pour cleaning solution into a bucket
of water. Solution can then be disposed of down a drain. Never
mix chemicals together. Always rinse bucket and drain area
after cleaning cell.
9.
Clean o-ring and face of electrode. Apply a film of silicone
lubricant to o-ring (just enough to make it shiny).
10. Refit electrode into housing and tighten locking ring.
11. Attach the output cable and the blue cap.
12. Reset valves, turn on pump and chlorinator, and confirm
output settings.
Resetting the Fuse
A resettable fuse is located above the power cord on the bottom
rear of the LM3 power pack. If the fuse is blown (popped, with
white area exposed):
•
Turn off all power to the Clearwater power pack.
•
Locate fuse and push to reset.
•
Restore power to unit.
Preventing Damage Caused by Insects
The case of the Clearwater power pack has small vents to allow
internal components to remain cool in hot weather. Sometimes
small insects enter the case of the power pack causing damage to
the internal electrical components. To avoid this, spray insect
repellent on surfaces around the power pack.