manualshive.com logo in svg
background image

3

3. Control box diagnosis

(delivered with the cleaner)

-

Connect the control box's power cable.

• 

On the control box, press 

 and hold for 10 seconds.

• 

Quick mode (fl oor only) fl ashes by default

. For control boxes with a screen, the

 message "diAG" is displayed 

at the same ti me.

• 

Press and release 

, Smart mode (fl oor, walls, water line) starts to fl ash

. For control boxes with a 

screen, the

 message "diAG" is displayed at the same ti me.

• 

Press 

 to start 

manual diagnosti cs of the control box

, in 2 steps:

1. LED test: 

all LEDs should be fl ashing. 

==> This is used to detect whether an LED is defecti ve; replace the control box where necessary.

2. Butt on test: 

press and release the butt ons shown below. All LEDs should be steadily lit for 2 seconds

. For control boxes 

with a screen, the

 message "GOOD" is displayed at the same ti me.

==> This is used to detect whether a butt on is defecti ve; replace the control box where necessary.

Example of a control box with the butt ons to be tested (butt ons may diff er depending on the model)

• 

To exit diagnosti cs mode, press 

.

All Alpha™ iQ control boxes can be used to perform Cleaner Diagnosti cs for any Alpha™ iQ model.