Is fill light
green or red?
YES
NO
YES
YES
NO
NO
NO
YES
YES
Pull sensor out of water.
Possible Issues:
1. Manual lever on valve needs
to be turned off.
2. Valve is dirty: take valve
apart and clean inside.
3. Diaphram is torn.
4. LED light needs to be aligned
with lens cover.
Possible Issues:
1. Needs greased-filled
wire nut at valve.
2. Needs proper wire between
controller and valve: solid-
core 18-gauge wire with
poly-pro jacket.
3. Valve is bad.
Possible Issues:
1. Needs greased-filled wire nut at valve.
2. Needs proper wire between controller and valve:
solid-core 18-gauge wire with poly-pro jacket.
3. Valve is bad.
PCB board
is bad.
Sensor is bad.
Does
green fill light
turn off?
Does
green fill light
turn off?
Is fill
light on?
Disconnect blue valve
wires from control box.
Does green
fill light turn off?
Wait 20 seconds.
Disconnect orange sensor
wires from control box
and touch them together.
Does sensor
light turn off?
Place sensor
back in water.
Fill Will Not Turn OFF
Lockout sequence
has taken effect.
Call technical support at
(707) 776-8200 ext. 260.
GREEN
RED
NO
5.4 Fill Will Not Turn OFF
This is a troubleshooting flow chart for the K-1100, LX2, and LEV110CK/2G. Use it when the Fill function will not
turn off.
Page 20
ENGLISH
Jandy Pro Series Levolor
®
Electronic Water Leveler
Models K-1100, LX2, K-2300, and LEV110CK/2G
|
Installation and Operation Manual