4.2 K-2300
The controller for the K-2300 has five (5) lights. See
Figure 24 and refer to Table 2. The Power light turns
green when the unit is on. The Sensor I light turns
yellow when water is not touching the Sensor I tips.
Twenty seconds later, the Filling I light turns green,
indicating that Valve I is operational and filling. The
light turns off when the pool is filled, and turns red
when Valve I goes into Safety Lockout Mode.
Figure 24. K-2300 Controller Lights
Electronic
Water Levelor
The next generation
in automated controls.
SM
TM
II
Patented
High Voltage Compartment
No user service parts inside
Model No. K-2300
Power
Sensor I
Filling I
Sensor II
Filling II
Sensor I
Filling I
Sensor II
Filling II
Power
LED
Function
Color
Operating
Mode
Delay to Turn Function
ON
Delay to Turn Function
OFF
Power
Turn Power ON
Green
Power is
ON
None
None
Sensor I
Detect Low Water
in Pool
Yellow Water in Pool
is Low
None
None
Filling I
Filling Pool
Green Fill I Valve is
ON
20 Seconds after Sensor
Light Turns ON
20 Seconds after Sensor
Light Turns OFF
Safety Lockout
Red
Fill I
Valve is
OFF
20, 40 or 60 Minutes
24 Hours
Sensor II Detect Low Water
in Spa
Yellow Water in Spa
is Low
None
None
Filling II
Filling Spa
Green Fill II
Valve is
ON
20 Seconds after Sensor
Light Turns ON
20 Seconds after Sensor
Light Turns OFF
Safety Lockout
Red
Fill II Valve is
OFF
20, 40 or 60 Minutes
24 Hours
The Sensor II light turns yellow when water is not
touching the Sensor II tips. Twenty seconds later, the
Filling II light turns green, indicating that Valve II is
operational and filling. The light turns off when the spa
is filled, and it turns red when Valve II goes into Safety
Lockout Mode.
Note that the K-2300 has two (2) Safety Lockout
features, one (1) for Valve I and the other for Valve
II. They operate independently. If one valve goes into
Safety Lockout Mode, the other valve can continue to
operate normally.
4.3 Fill Safety Lockout Mode
The Fill Safety Lock-out Mode shuts the Filling I or
Filling II valve down for 24 hours or until the unit is
powered down and back up to reset the filling time.
When the unit goes into lock-out, it indicates a possible
problem with the control, sensor, or water fill line
system. The 24-hour window provides time to find and
fix the problem. If the problem has not been fixed after
24 hours, the control will lock out for another 24 hours.
All four (4) models described in this manual are
equipped with a lock-out sequence. This means that
if the Levolor
®
sensor has not been touched by water
within the pre-set Fill time period, the controller turns
the valve off for 24 hours and changes the Filling I or
Filling II light from green to red.
The pre-set factory Fill time for the K-1100, LX2,
and K-2300 is 20 minutes, but it can be modified to
40 or 60 minutes. The pre-set factory Fill time for the
LEV110CK/2G is one (1) hour, but it can be modified
to two (2) or three (3) hours. See Table 1 for pre-set and
modified Fill times. See
Section 4.4
for instructions on
modifying pre-set Fill times.
Table 2. LED Indicators for K-2300
Page 17
ENGLISH
Jandy Pro Series Levolor
®
Electronic Water Leveler
Models K-1100, LX2, K-2300, and LEV110CK/2G
|
Installation and Operation Manual