background image

P a g e 

31 

 

 

Section 8.Replacement Parts and Exploded Views 

8.1

 

Parts List 

 

 

Key No.  Description 

Order Part No. 

Cell 

R-Kit, Terminal Cap, APURE Ei

TM

 

R0511200 

2* 

R-Kit, Locking Ring 

R0511300 

3* 

R-Kit, Electrode, APURE Ei 35 

R0511400 

4* 

R-Kit, O-Ring, Electrode Housing 

R0511600 

5* 

R-Kit, Saddle Clamp Assy, APURE Ei 

R0511700 

Power Pack 

R-Kit, Power PCB Assy, APURE 35 

R0512100 

7** 

R-Kit, Control PCB Assy, APURE Ei 

R0512300 

8** 

R-Kit, Cover Assy, Controller, APURE Ei 

R0512400 

R-Kit, Output Cable Assy, APURE Ei 

R0512500 

10 

R-Kit, Screws, PCB Mounting, APURE Ei 

R0512800 

11 

R-Kit, Screws, Cover, Power Supply, APURE Ei 

R0512900 

Miscellaneous 

12 

R-Kit Locking Ring Tool 

R0512600 

13* 

R-Kit, Winterizing Kit 

R0512700 

 

*

 

Replacement o-ring supplied in this kit 

** Screws are supplied in this kit 

Содержание Ei Series

Страница 1: ...ols a range of 1 3 ppm of free available chlorine must be maintained Controls bacteria and algae in swimming pool water Do not use this device with bromide products BUILDER INSTALLER Please leave this...

Страница 2: ...IRE OR EXPLOSION KEEP OUT OF REACH OF CHILDREN Notice to User This pest control product is to be used only in accordance with the directions on the label It is an offence under the Pest Control Produc...

Страница 3: ...6 2 Wiring to the AquaLink RS Control System or PDA 14 3 6 3 Testing the Connection 16 3 7 Bypass Plumbing Instructions If Flow Rate Exceeds 348 LPM 92 GPM 17 3 8 Split Return Plumbing Instructions Fo...

Страница 4: ...gure 2 Carton Contents 9 Figure 3 Installation Requirements 10 Figure 4 Installation Requirements 11 Figure 5 Attaching the Power Pack 11 Figure 6 Disassemble Cell 11 Figure 7 Marking Pipe for Drillin...

Страница 5: ...e Cell 27 Figure 28 Invert the Cell 27 Figure 29 Winterizing Cap Installed 28 Figure 30 Locking Ring Level 28 Figure 31 Cell Exploded View 33 Figure 32 Winterizing Cap and Locking Ring Tool 33 Figure...

Страница 6: ...d should only be replaced by the manufacturer service agent or electrician When installing and using this electrical equipment always follow basic safety precautions Before performing installation dis...

Страница 7: ...f your operational system at least 1 m 3 ft from the pool so children cannot use the equipment to access the pool and be injured or drown WARNING People with a medical condition should consult a physi...

Страница 8: ...tub The use of alcohol drugs or medication can greatly increase the risk of fatal hyperthermia in hot tubs and spas Water temperature in excess of 38 C 100 F may be hazardous to your health CAUTION T...

Страница 9: ...ral stone especially when used outdoors be sealed to prevent weathering staining and premature degradation Consult with your stone or deck contractor for the proper sealer for the masonry products you...

Страница 10: ...olytic Cell L x W x H 16 5 cm x 14 cm x 30 5 cm 6 5 in x 5 5 in x 12 in Maximum water volume treated 132 000 L 35 000 gal Chlorine Output 0 42 kg 0 93 lbs per day Input Voltages 240 V or 120 V the sys...

Страница 11: ...mage severe injury or death Before you begin your installation please check that you have the right tools and a suitable location to install the power pack and cell Please ensure that you have read an...

Страница 12: ...an AquaLink RS Control System or PDA see Section 3 6 5 Unscrew the locking ring from the cell in order to extract it from the upper clamp see Figure 6 6 Press the two 2 push buttons on either side of...

Страница 13: ...allation codes may require the equipment to be properly bonded to other pool equipment or to a bonding grid Bonding per Section 3 5 must also be accomplished to ensure personal safety and safety of eq...

Страница 14: ...otices and instructions may result in property damage serious injury or death Improper installation and or operation will void the warranty When using electrical products basic precautions should alwa...

Страница 15: ...Rate Exceeds 348 L min 92 GPM WARNING If flow rate exceeds 348 L min 92 gpm the cell must be plumbed on bypass otherwise it may result in property damage personal injury or death NOTE Pool pumps grea...

Страница 16: ...swimming pool water Nitrates can cause extremely high chlorine demands and will deplete chlorine from your swimming pool Insome cases nitrates may even lower your chlorine levels to zero Your local po...

Страница 17: ...s scaling of the cell Sequestering Agents can be used to compensate for source water which may have unusually high calcium hardness High calcium hardness can contribute to scale formation in the pool...

Страница 18: ...aken from two 2 places described below Compare the two 2 samples A higher level should be found at the pool return line The higher level at the pool return line indicates the salt water chlorinator sy...

Страница 19: ...nd your pool and or spa please discuss all options with your contractor to assess the compatibility of such materials and chemicals When mixing acid with water ALWAYS ADD ACID TO WATER NEVER ADD WATER...

Страница 20: ...34 lbs 227 kgs 501 lbs 303 kgs 668 lbs 379 kgs 835 lbs 454 kgs 1001 lbs 530 kgs 1168 lbs 250 142 kgs 313 lbs 213 kgs 469 lbs 284 kgs 626 lbs 355 kgs 782 lbs 426 kgs 939 lbs 497 kgs 1095 lbs 500 132 kg...

Страница 21: ...gs 5 1 lbs 2 9 kgs 6 3 lbs 3 4 kgs 7 6 lbs 4 0 kgs 8 9 lbs 30 0 8 kgs 1 7 lbs 1 2 kgs 2 5 lbs 1 5 kgs 3 4 lbs 1 9 kgs 4 2 lbs 2 3 kgs 5 1 lbs 2 7 kgs 5 9 lbs 40 0 4 kgs 0 8 lbs 0 6 kgs 1 3 lbs 0 8 kgs...

Страница 22: ...light The output can be adjusted in increments of 20 up to 100 If the OUTPUT button is pressed beyond 100 the output level setting will drop back to 20 5 5 Connection to an AquaLink RS PDA Control Sy...

Страница 23: ...power pack is fitted with a rechargeable battery which can last in excess of 500 hours without the power being connected In the event of a power failure the battery will retain ALL settings In the ev...

Страница 24: ...geographic areas with excessive evaporation and minimal dilution of pool water with fresh water A build up of by products can damage the electrolytic cell 3 Total Alkalinity Test Test pool water for t...

Страница 25: ...as follows 1 Ensure that all power to the power pack and the controller is disconnected turned off at the circuit breaker 2 Before removing the cell for cleaning shut off any necessary valves to prev...

Страница 26: ...he line During the cold season if you are using a FREEZE CONTROLLER on pump equipment and you choose to keep the chlorinator installed turn the CHLORINE PRODUCTION down to 20 otherwise chlorine produc...

Страница 27: ...eavy organic load rain leaves fertilizer or heavy bather load Pets using pool Set chlorine production to 100 and set the pump and the cell to run for 24 hours After 24 hours recheck chlorine levels If...

Страница 28: ...the connection to the pump timer see Section 3 4 Check if GFCI tripped Problem Possible Cause Corrective Action Flow light is on Display says No Flow Caused by insufficient water flow through the cel...

Страница 29: ...ht is off A combination of low water temperature 2 18 C 35 65 F and lower salt levels 3 500 4 000 ppm Check salt level in pool water If level is between 4 000 4 500 ppm no action is necessary If salt...

Страница 30: ...growth Brush down the affected walls and then manually shock the pool see Section 4 3 Problem Possible Cause Corrective Action Eye and or skin irritation Improper water balance Balance the water to re...

Страница 31: ...le Clamp Assy APURE Ei R0511700 Power Pack 6 R Kit Power PCB Assy APURE 35 R0512100 7 R Kit Control PCB Assy APURE Ei R0512300 8 R Kit Cover Assy Controller APURE Ei R0512400 9 R Kit Output Cable Assy...

Страница 32: ...iac Pool Systems Inc 2620 Commerce Way Vista CA 92081 1 800 822 7933 www ZodiacPoolSystems com ZODIAC is a registered trademark of Zodiac International S A S U used under license All trademarks refere...

Страница 33: ...HILDREN The maximum volume of water that can be treated with one unit of model Zodiac AquaPure Ei Series APURE35C is 132 000 litres 132 m3 For swimming pools a range of 1 3 ppm of free available chlor...

Страница 34: ...c AquaPure Ei Series APURE35C Registration Number s 30232 PEST CONTROL PRODUCTS ACT This cell must be only used on this model of chlorine generating device Read the label Installation and Operating Ma...

Страница 35: ......

Отзывы: