14
3.6.1
Verify the Controller Type on the Power Pack is Set Correctly
Before wiring to an AquaLink RS Control System, the controller type must be set to JANDY L/M to allow
communication between the power pack and the AquaLink RS Control System. The default controller type setting on the
power pack is Jandy L/M. Follow the instructions below to verify the controller type is set correctly.
NOTE
The controller type must be set correctly before making the wiring connection between the power pack and the
AquaLink, otherwise the power pack may be locked out of the AquaLink.
To verify the controller type is set correctly:
1.
Apply power to the power pack.
2.
Wait for the start-up sequence to complete.
3.
Press and hold the OUTPUT button for approximately four (4) seconds. After four (4) seconds, a controller type
will be displayed on the screen.
4.
Verify that the JANDY L/M controller type appears on the display. If the controller type is not set to JANDY L/M, keep
the OUTPUT button pressed to toggle through the list of controllers. Each controller will be displayed on the screen for
two (2) seconds. Release the OUTPUT button when JANDY L/M appears on the display.
WARNING
FOR YOUR SAFETY: This product must be installed and serviced by a professional pool/spa service technician as
described on the front cover of this manual.
The procedures in this manual must be followed exactly. Failure to follow
warning notices and instructions may result in property damage, serious injury, or death. Improper installation and/or
operation will void the warranty.
When using electrical products, basic precautions should always be followed, including the following:
•
DANGER: RISK OF ELECTRIC SHOCK WHICH CAN RESULT IN SERIOUS INJURY OR DEATH. Before
attempting installation or service, ensure that all power to the device is disconnected/turned off at the circuit
breaker. Connect only to a circuit protected by a ground-fault circuit-interrupter (GFCI).
•
Grounding is required. The unit should be serviced by a qualified service representative and should be properly
grounded. (See Section 3.4, Wiring the Power Pack to Power Source).
•
Install to permit access for servicing.
•
Please read all cautions and safety instructions in the Important Safety Instructions section.
Before attempting
any electrical wiring, be sure to read and follow safety instructions. Wiring should only be attempted by a
qualified professional.
3.6.2
Wiring to the AquaLink RS Control System or PDA
1.
Ensure that all power to the power pack and the controller is disconnected/turned off at the circuit breaker.
2.
Remove the screws attaching the cover to the back plate and prop the cover up to expose the terminals
(see Figure 19).
NOTE
Be careful not to pull the ribbon cable that is connected to the Power Supply and the Cover.
3.
Remove the white cap covering the comm hole (see Figure 19).
4.
Thread the controller cable through the hole. A grommet may be necessary depending on the size of the
cable being used.
5.
Attach a cable tie to the controller cable as shown (see Figure 19).