No Flow LED
•
“NO FLOW” is displayed when there is insufficient or no water flow
through the cell.
•
The minimum flow rate is 40 gpm.
•
It may also activate if the flow pod is installed at more than 45° to
the
verticle
or if the flow switch paddle has been turned within
the flow
pod.
(This would apply only to the PLG model)
Verify water is touching flag at the end of the blue wire.
If system reads no flow but water is touching flag:
•
Test by placing a jumper temporarily between the black and blue
wires on the three pin connector (second pin and third pin from left to
right) on the PCB.
•
If system reads flow with jumper in place then power PCB is good.
•
Problem is with cell terminals or cell wires.
•
Remember to remove jumper after test.
Flag
2.5 amp fuses
Bl
k
Rd
Fan
OV POS B A
100-265 VAC
Temporary Jumper
Notes:
Troubleshooting -
No Flow
15