AERAZUR
COMPONENT MAINTENANCE MANUAL
C10 LIFE JACKET
25-65-09
REV
12
PAGE
401
CLEANING
1.
General
After use, the life jacket must be cleaned as soon as possible.
For the testing equipment required, refer to the “SPECIAL TOOLS, FIXTURES AND
EQUIPMENT MATERIALS” section.
Use cleaning solvents in well-ventilated premises.
Do not put seams or markings in contact with solvents.
Use clean, dry, non-fluffy cloths.
Use a source of compressed air free of oil and humidity and fitted with a 20 micron filter.
After cleaning, keep drying life jackets in a well-ventilated place before storing them.
2.
Procedures
A.
Textile components
(1).
Use a solution of TEEPOL diluted in hot water to clean the life jacket.
(2).
To remove spots of grease or paint, rub the affected parts with a cloth soaked in neat
TEEPOL.
Immediately after cleaning, remove all excess solvent using a cloth and leave to dry.
B.
Metal and plastic parts
(1).
These parts are cleaned and the dust removed from them using a cloth and
compressed air.
(2).
For oil and grease stains, use a solution of TEEPOL and hot water.
Rinse with clean water and dry with compressed air.