14
When cleaning the modules, use a soft cloth together with a mild detergent and clean water. Take
care to avoid severe thermal shocks which might damage the module by cleaning modules with
water which has a similar temperature to the modules being cleaned.
Use dry or wet soft clean cloth to clean the PV modules; non-corrosive solvents or hard objects are
strictly prohibited;
If there are greasy dirt and other substances on the surface of the PV module which are difficult to
clean, conventional household glass cleaning agents can be used; Do NOT use the alkaline and
strong acid solvents.
The back surface of the module normally does not need to be cleaned but, in the event this is
deemed necessary, avoid the use of any sharp projects that might damage the penetrating the
substrate material.
11. Specification
Module Series
60pcs 156.75×156.75mm Polycrystalline Silicon DOUBLE GLASS Module
Dimensions(mm)/ Weight(kg)
1658*992*6
Max-System Voltage (VDC)
1500
Max-Series Fuse(A)
15
Electrical Performance @ STC
Model Type
ZXP6-TD60-270/P
ZXP6-TD60-275/P
ZXP6-TD60-280/P
Max-Power Pm(W)
270
275
280
Max-Power Voltage V
mp
(V)
31.3
31.5
31.7
Max-Power Current I
mp
(A)
8.63
8.74
8.84
Open Circuit Voltage Voc(V)
38.0
38.2
38.3
Short Circuit Current Isc(A)
9.30
9.39
9.52
Module Series
60pcs 156.75×156.75mm Mono crystalline Silicon DOUBLE GLASS Module
Dimensions(mm)/ Weight(kg)
1658*992*6
Max-System Voltage (VDC)
1500
Max-Series Fuse(A)
15
Electrical Performance @ STC
Model Type
ZXM6-TD60-
300/M
ZXM6-TD60-
305/M
ZXM6-TD60-
310/M
ZXM6-TD60-
315/M
ZXM6-TD60-
320/M
Max-Power Pm(W)
300
305
310
315
320
Max-Power Voltage V
mp
(V)
32.7
32.9
33.1
33.3
33.5
Max-Power Current I
mp
(A)
9.18
9.28
9.37
9.46
9.56
Open Circuit Voltage Voc(V)
39.6
39.8
40.0
40.2
40.4
Short Circuit Current Isc(A)
9.90
9.93
9.96
9.98
10.03
Содержание ZXM6- TD72- 370/M
Страница 1: ...Installation Manual for Double Glass June 27 2018...
Страница 12: ...10...
Страница 14: ...12 10 Care and maintenance 10 1 PANEL VISUAL INSPECTION AND REPLACEMENT...