background image

for the PCD7.D61x0TL series  

(embedded Windows XP)

Controls Division

Hardware Manual

Document 26/865; Version pEN1 | 2009-06-11

Summary of Contents for PCD7.D61 0TL Series

Page 1: ...for the PCD7 D61x0TL series embedded Windows XP Controls Division Hardware Manual Document 26 865 Version pEN1 2009 06 11...

Page 2: ...Switch on 3 2 4 Basic settings and first steps 5 Technical data 5 1 Physical dimensions 5 1 5 1 1 PCD7 D6100TLxxx exterior flush mounting dimensions 5 2 5 1 2 PCD7 D6100TLxxx unit dimensions 5 3 5 1...

Page 3: ...Manual for the PCD7 D61x0TL series Document 26 865 Version pEN1 2009 06 11 Saia Burgess Controls AG Contents 0 2 0...

Page 4: ...ial version 0 2 Trademarks Saia is a registered trademark of Saia Burgess Controls AG Microsoft Windows 2000 Windows XP Windows CE and the Windows logo are either registered trademarks or trademarks o...

Page 5: ...r use with the Windows xXP open operating system The 2 USB ports can be used to connect external keyboards mice USB sticks or certain models of printer The integrated Ethernet interface allows the uni...

Page 6: ...use of special procesors dispnses with the need for sensitive fan systems Hard disks are replaced with Compact Flash cards so the breakdown rate is very low in spite of the often harsh industrial envi...

Page 7: ...the PCD7 D61x0TL series Document 26 865 Version pEN1 2009 06 11 Saia Burgess Controls AG User side Slot side Product description 2 2 2 2 1 User side Colour resistive touch TFT display 10 4 12 or 15 2...

Page 8: ...act Flash card should only be changed with the device switched off 2 3 2 VGA COM1 PS 2 interface VGA port COM 1 PS 2 mouse keyboard PS2 adapter cable for mouse and keyboard On all standard PCD7 D61xxT...

Page 9: ...Manual for the PCD7 D61x0TL series Document 26 865 Version pEN1 2009 06 11 Saia Burgess Controls AG Back Product description 2 4 2 2 3 3 Ethernet USB Ethernet 1 RJ45 Ethernet 2 RJ45 USB 1 2 2 4 Back...

Page 10: ...ansformer must comply with EN60742 The supply voltage must be checked against the type plate When wiring the power supply andthe connector the details on the type plate must be observed Before commiss...

Page 11: ...r a metal switching cabinet Adequate ventilation must be provided To ensure that the heat generated in the device can be dissipated a 100 mm space must be kept clear around the unit The device is secu...

Page 12: ...eries Document 26 865 Version pEN1 2009 06 11 Saia Burgess Controls AG Taskbar Basic settings and first steps 4 1 4 4 Basic settings and first steps This section is still being written and will be pub...

Page 13: ...rsion pEN1 2009 06 11 Saia Burgess Controls AG Physical dimensions Technical data 5 1 5 5 Technical data 5 1 Physical dimensions Clearance To ensure that the heat generated in the device can be dissip...

Page 14: ...Aperture size Width 303 mm Height 228 mm Depth 77 mm Weight approx 2 8 kg Type of fixing 6 aluminium or plastic brackets with M5 30 grubscrews DIN 914 with head and hexagonal recess zinc plated 303 0...

Page 15: ...urgess Controls AG Physical dimensions Technical data 5 3 5 5 1 2 PCD7 D6100TLxxx unit dimensions 244 318 R5 8 5 94 5 214 5 235 5 23 67 6 193 301 23 5 8 5 120 227 Seitenansicht Blick auf die Ger teobe...

Page 16: ...Width 345 mm Height 277 mm Depth 77 mm Weight approx 2 8 kg Type of fixing 8 M4 threaded bolts recessed into the front plate Surround thickness max 5 0 mm 296 0 8x Bohrung 4 5 364 0 354 0 255 5 277 0...

Page 17: ...Controls AG Physical dimensions Technical data 5 5 5 5 1 4 PCD7 D6120TLxxx dimensions Blick auf die Ger teoberseite Blick auf die Ger ter ckseite Seitenansicht rechts Blick auf die Ger teunterseite S...

Page 18: ...29 mm Height 334 mm Depth 86 mm Weight approx kg Type of fixing 6 aluminium or plastic brackets with M5 30 grubscrews DIN 914 with head and hexagonal recess zinc plated Fronttafeldurchbruch f r den Ei...

Page 19: ...ntrols AG Physical dimensions Technical data 5 7 5 5 1 6 PCD7 D6150TLxxx unit dimensions Blick auf die Ger teoberseite Blick auf die Ger ter ckseite Seitenansicht rechts Blick auf die Ger teunterseite...

Page 20: ...512 MB Chipset AMD LX series CS5536 I O chipset IT8712 FKX IT8888G BIOS Award 512 KB FLASH ROM Battery CR2032 lithium battery SSD Internal type II Compact Flash Display chipset AMD LX series TI SN75LV...

Page 21: ...its do not have to be taken out of the switching cabinet It is sufficient to loosen the two screws on the back plate hexagonal recess size 2 0 and open the back plate downwards Hold the back plate rou...

Page 22: ...olution or dilute washing up liquid Always use a clean soft cloth for cleaning Do not use any cleaning agents that contain granules e g scouring powder or cleansing milk These may affect the readabili...

Page 23: ...ions are not taken This symbol warns the reader of the risk to components from electrostatic discharges caused by touch Recommendation Before coming into contact with electrical components you should...

Page 24: ...Saia Burgess Controls AG Bahnhofstrasse 18 CH 3280 Murten Switzerland Tel 41 26 672 71 11 Fax 41 26 672 74 99 E mail pcd saia burgess com Homepage www saia pcd com Support www sbc support ch Postal ad...