ZMC460 Motion Controller User Manual V1.5
⚫
Please use STP cables, especially in harsh environments, and make sure the
shielding layer is fully grounded.
→
Cable Requirements:
Shielded Twisted Pair, and the shielded cable is grounded.
3.6.2.
Basic Usage Method
(1)
Please follow the above wiring instructions to wiring correctly.
(2)
After powered on, please use any one interface among the three interfaces ETHERNET,
RS232 and RS485 to connect to ZDevelop.
(3)
Analog input voltage can be read through “AIN” command and corresponding analog
voltage can be output
through “AOUT” command, also, data of each channel can be
checked through “ZDevelop/View/AD/DA”. Please refer to “ZBasic” for details.