ZMC412 Motion Controller User Manual V1.5
Respond time to
close
3μs
80μs
Overcurrent
protection
Support
Support
Isolation method
optoelectronic isolation
Note:
The times in the form are typical based on the resistive load, and may change
when the load circuit changes.
Due to the leak-type output, the shutdown of the output will be obviously
affected by the external load circuit, and the output frequency should not be set
too high in the application.
→
Wiring Reference
→
Wiring Note:
⚫
The wiring principle of high-speed digital outputs OUT (0-3) and low-speed digital
outputs OUT (4-11) are shown in the figure above. The external signal receiving end
can be an optocoupler or a relay or solenoid valve, all can be connected as long as
the input current does not exceed 300mA.
⚫
For the connection of the common terminal, please select the "EGND" port on the
power terminal to connect to the negative pole of the DC power supply of the external
input device. If the DC power supply of the external device and the controller power
supply are in the same power supply system, this connection can also be omitted.